Plan Review Details - Permit 17030929
| Plan Review Stops For Permit 17030929 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-04-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-04-14 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-27 |
Time |
15:23 |
Sent To |
M |
|
| Notes |
| 2017-03-27 15:48:17 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) | | | THE SUBMITTED APPLICATION INDICATES AS-BUILT FIRE | | | SPRINKLER PLANS AND THE SUBMITTED PLAN SHEET INDICATES | | | AS BUILT; HOWEVER, THE SUBMITTED PLAN SHEET(S) DOES NOT | | | (DO NOT) INDICATE ANY CLOUD REVISIONS, CALL OUTS AND/OR | | | NOTES INDICATING WHAT AREAS, DEVICES, HEADS, PIPING, | | | ETC IS AS-BUILT OR REVISED FROM THE MASTER PERMIT. | | | | | | PER NFPA 1 | | | | | | 1.14.5 WHEN REQUIRED BY THE AHJ, REVISED CONSTRUCTION | | | DOCUMENTS OR SHOP DRAWINGS SHALL BE PREPARED AND | | | SUBMITTED FOR REVIEW AND APPROVAL TO ILLUSTRATE | | | CORRECTIONS OR MODIFICATIONS NECESSITATED BY FIELD | | | CONDITIONS OR OTHER REVISIONS TO APPROVED PLANS. | | | | | | PLEASE CLEARLY INDICATE THE EACH AREA OR PIECE OF | | | EQUIPMENT REVISED/AS-BUILT ON THE PLAN SHEETS. | | | | | | | | | | | | 2) | | | THE SUBMITTED SHEETS WERE NOT BOUND TOGETHER OR | | | ORGAINZED SO THEY CAN NOT SEPARATE. | | | | | | PLEASE BIND AND/OR STAPLE YOUR SUBMITTED PLAN SHEETS | | | INTO ORGANIZED SETS. | | | | | | | | | | | | 3) | | | WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION | | | CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | | | | | | | 4) | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-04-26 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-04-13 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2017-04-14 09:17:20 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-04-03 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-03-23 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2017-03-24 09:38:26 | REVISION ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-04-26 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-04-26 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-04-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-03 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-04-03 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2017-04-03 09:07:07 | PLAN DENIED SEE FIRE COMMENTS. HM. |
|
|
|
Account Summary | Usage Policy | Privacy Policy