Plan Review Details - Permit 17030708
| Plan Review Stops For Permit 17030708 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-15 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-15 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2017-05-15 12:13:01 | PROVISO | | | WINDOWS: U = .30 | | | SHGC = .25 | | | | | | PER ENERGY CALCS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-27 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-27 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2017-03-27 15:11:22 | PROVISO | | | WINDOWS: U = .30 | | | SHGC = .25 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-17 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-17 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-23 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-23 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-03-23 14:33:03 | | | | 17030708 | | | 801 DOBBINS STREET | | | APARTMENT REMODEL | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | THE PLANS AS SUBMITTED ARE DEFICIENT OR MISSING | | | INFORMATION IN THE FOLLOWING AREAS. | | | | | | LOCATION OF PANEL BOARDS, AIR CONDITIONING EQUIPMENT, | | | DISCONNECTS, TAMPER RESISTANT RECEPTACLES, MISSING | | | RECEPTACLES, INTERCONNECTION OF SMOKE DETECTORS, ARC | | | FAULT RECEPTACLES ARE REQUIRED THROUGHOUT, REQUIRED | | | LAUNDRY CIRCUITS, SPECIFICATIONS FOR CEILING FIXTURES, | | | ENERGY EFFICIENCY SPECS FOR LAMPS, HOUSE PANEL | | | DIRECTORY, SERVICE LOCATION, SERVICE RISER HEIGHT, | | | SERVICE DROP HEIGHT, WIRE SIZES FOR SERVICE, WIRE SIZES | | | FOR WATER HEATERS, WIRE SIZES FOR PANELS, MAIN | | | DISCONNECTS, INTERSYSTEM GROUNDING BAR, SERVICE FAULT | | | CURRENT CALCULATIONS, PANEL BOARD FAULT CURRENT | | | CALCULATIONS, ARC FAULT SAFETY LABELING, APARTMENT LOAD | | | CALCULATION. | | | | | | NOTE THAT AIR CONDITIONING, HEATING, LAUNDRY, RANGE AND | | | DRYER LOADS WERE NOT INCLUDED IN THE LOAD CALCULATIONS | | | AND NEED TO BE ADDED IF THEY WILL BE PART OF THIS | | | SUBMITTAL. | | | | | | NEC CODE SECTIONS: 210.12, 110.9, 110.10, 406.11, | | | 250.94, 210.52 (F), 410.116, 110.26, | | | | | | FBC CODE SECTIONS: E3902.12, E3609, E3703.3, ER404.1, | | | E4004.8 | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6654(OFFICE) | | | 561-373-3701(CELL) | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-17 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-02 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-29 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-16 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-08 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-08 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-28 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-28 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2017-03-28 08:50:42 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030708 | | | 3/28/17 | | | | | | 1) SHEET 3.0: PLEASE IDENTIFY ALL ROOMS AND SPACES ON | | | THE FLOOR PLANS- SECTION 107.2.1 WPB AMENDMENTS TO THE | | | FBC. | | | | | | 2) ENERGYGAUGE FORM R405-2014: | | | | | | A) THE IDENTIFICATIONS OF THE APARTMENTS ON THE FORMS | | | (A, B ETC.) DO NOT MATCH THE PLANS WHICH LISTS THE | | | UNITS NUMERICALLY. PLEASE CORRELATE THE PLANS AND | | | CALCULATIONS SO THEY MATCH. | | | | | | B) THE FORMS ARE LACKING COMPLETE PROJECT INFORMATION | | | AND DATA AT THE TOP OF THE FORM AND ARE NOT SIGNED BY | | | THE OWNER/AGENT. | | | | | | C) THE FORMS ARE INDICATING A "WORST CASE" COMPLIANCE | | | WHICH IS ONLY PERMITTED FOR MODEL HOME COMPLIANCE- SEE | | | SECTION R405.4.2 EXCEPTION. | | | | | | D) THE CHECKLISTS HAVE NOT BEEN COMPLETED. | | | | | | 4) SHEET 3.0: PROVIDE THE EQUIPMENT SCHEDULES FOR AHU'S | | | # 2 & 3. PLEASE NOTE ENERGYGAUGE FORM R405 AND THE AC | | | CALCULATIONS EACH LIST THE SYSTEMS AS 16 SEER. | | | | | | 5) 3.0, 1ST FLOOR APT: | | | | | | A) PROVIDE THE SIZE OF THE BEDROOM/HALLWAY TRANSFER | | | DUCT. | | | | | | B) CLARIFY IF AHU-3 HAS AN OPEN RETURN BECAUSE THE | | | D/600 RETURN GRILL IS UNDERSIZED. | | | | | | 6) 3.0: 2ND FLOOR: | | | | | | A) PROVIDE THE FLEX DUCT SIZES, | | | | | | B) THE BEDOOM TRANSFERS ARE MISLABELED AS SUPPLY | | | DIFFUSERS AND ARE UNDERSIZED- 50 SQ. INCHES PER 100 | | | CFMS REQUIRED. ONE BEDROOM TRANSFER IN UNIT 201 IS NOT | | | LABELED. | | | | | | C) INDICATE WHICH TYPE OF BI-FOLD DOORS ARE ENCLOSING | | | THE AHU CLOSETS. | | | | | | 7) PROVIDE KITCHEN AND BATH EXHAUST SYSTEMS IN | | | ACCORDANCE WITH TABLE M1507.4 FBC-14 RESIDENTIAL. SEE | | | ALSO SECTION R303.3 FOR BATHROOM VENTILATION IF USING | | | AN OPERABLE WINDOW. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-12 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-29 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-29 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2017-03-29 15:39:12 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE PLUMBING RISER DIAGRAM. PER WPB AMEND TO FBC | | | 107.3.5.3(11) | | | | | | 2. PROVIDE MANUFACTURE SPECIFICATION FOR TANKLESS WATER | | | HEATER. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. PROVIDE EXISTING PLUMBING LAYOUT FLOOR PLAN. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
|