Plan Review Details - Permit 17030698
| Plan Review Stops For Permit 17030698 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-04-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-04-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-04-14 |
Time |
16:08 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-03-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-21 |
Time |
12:24 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-27 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-13 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2017-04-14 11:10:24 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-23 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-16 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2017-03-17 12:44:12 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-27 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-27 |
Time |
17:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-23 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-23 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2017-03-23 15:12:54 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030698 | | | 3/23/17 | | | | | | 1) SHEET M: INDICATE THE DISCHARGE HEIGHT OF THE GREASE | | | EXHAUST OUTLET MEASURED FROM THE ROOF SURFACE- SECTION | | | 506.3.13.1. | | | | | | 2) PROVIDE A GUARD AT THE ROOF EDGE BY THE EXHAUST FAN | | | IN COMPLIANCE WITH SECTION 304.11. | | | | | | 3) PROVIDE AN AIR VELOCITY CALCULATION FOR THE GREASE | | | EXHAUST DUCT- SECTION 506.3.4. | | | | | | 4) REFER TO SECTION 508.1.1: THE TEMPERATURE | | | DIFFERENTIAL BETWEEN MAKEUP AIR AND THE AIR IN THE | | | CONDITIONED SPACE SHALL NOT EXCEED 10 DEGREES F. THIS | | | TYPICALLY REQUIRES THE INSTALLATION OF A AC SYSTEM TO | | | PROVIDE THE SUPPLY AIR. | | | | | | 5) THE COPIED PLAN SHEET FROM THE MAIN PERMIT MUST BE | | | NOTED TO BE "FOR REFERENCE ONLY" BY THE ENGINEER OF | | | RECORD, OR PROVIDE A NEW REVISED SHEET WITH AN ORIGINAL | | | SEAL AND SIGNATURE BY THE ENGINEER. PLEASE NOTE THAT | | | THE WIDTH DIMENSION OF THE HOOD ON THE PLAN DOES NOT | | | MATCH THE WITH DIMENSION ON SHEET M. | | | | | | 6) PROVIDE THE OWNER INFORMATION, THE PROJECT NAME, AND | | | PCN ON THE PERMIT APPLICATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|