| 2017-06-02 10:24:25 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUB-SURFACE INVISTEGATION BY SOILPROBE ENGINEERING & | | | TESTING, INC. SPECIFIES THE INSTALLATION OF PIN PILES | | | AND HELICAL-PIERS WITH A SPACING OF NOT GREATER THAN 8 | | | FEET ON CENTER. ( SEE PAGES 3 & 4 OF REPORT AND PLAN | | | PAGE S1.0) PLEASE CLARIFY. | | | 2. PLAN PAGE A-002 SPECIFIES THE REMOVAL OF AN INTERIOR | | | LOAD BEARING WALL. PLAN PAGE S2.0 SPECIFIES THIS WALL | | | TO REMAIN. IF BEARING WALL IS TO BE REMOVED, PROVIDE | | | SHORING DETAIL. PLEASE CLARIFY. | | | 3. PROVIDE LINTEL/BEAM SCHEDULE. | | | 4. PROVIDE WINDOW AND DOOR SCHEDULE WITH ROUGH OPENINGS | | | AND DESIGN WIND LOADS. | | | 5. DETAIL 2, PAGE S0.1 IS NOT APPLICABLE TO THIS | | | PROJECT. NEW ROOF CONSISTS OF 2X10 P.T 16 INCHES ON | | | CENTER. | | | 6. PROVIDE DETAIL OF VERTICAL RE-INFORCING FOR 8" CMU | | | IN-FILL. | | | 7. PROVIDE DETAIL FOR THE REMOVAL OF FRENCH DOORS AND | | | INSTALLATION OF DOUBLE WINDOWS. | | | 8. NO MECHANICAL PLAN SUBMITTED. CANNOT VERIFY IF THERE | | | WILL BE ADDITIONAL CONDITIONED SPACE. | | | 9. PLAN PAGE A-007 TO BE SIGNED AND SEALED BY DESIGNER | | | OF RECORD. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-06-20 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-06-20 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-06-01 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-06-01 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2017-06-01 14:40:07 | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS AS WELL. | | | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | | INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND | | | OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS | | | APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON | | | MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH | | | ROOM USED FOR SLEEPING. 2014 FBC R314, 315 | | | | | | HIGH HAT CEILING LIGHTING FIXTURES IN INSULATED SPACES | | | NEED TO BE RATED FOR INSULATION CONTACT (IC). FBC | | | E4004.8 | | | | | | A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED | | | LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS OR A | | | MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING | | | FIXTURES SHALL CONTAIN HIGH EFFICIENCY LAMPS. FBC | | | ER404.1 | | | | | | THE PLANS DO NOT INDICATE THE SIZE OR WIRING METHOD FOR | | | THE NEW CIRCUITS. RECEPTACLES IN THE KITCHEN FOR THE | | | COUNTER TOP SHALL BE SERVED BY A MINIMUM OF TWO 20 | | | AMPERE BRANCH CIRCUITS. FBC E3901.3, E3901.4 | | | | | | INCLUDE A PANEL SCHEDULE SHOWING THE NEW CIRCUITS WITH | | | APPROPRIATE OVERCURRENT PROTECTION. NEC 110.26, FBC R | | | E3405.1, E3706.2 | | | | | | ALL NEW CIRCUITS MUST BE PROTECTED WITH ARC FAULT | | | CIRCUIT BREAKERS. FBC E3902.12, NEC 210.12 | | | | | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.2; | | | FBC R E4002.14 | | | | | | AN INTERSYSTEM BONDING SYSTEM IS REQUIRED AT THE | | | SERVICE GROUNDING SYSTEM. FBC E3609.3 | | | | | | GFCI PROTECTED RECEPTACLES ARE REQUIRED AT THE FRONT | | | AND REAR ELEVATIONS. FBC E3902,NEC 210.8 | | | | | | RECEPTACLES LOCATED AT THE KITCHEN ISLAND COUNTER | | | REQUIRE GFCI PROTECTION. FBC E3902 NEC 210.8 | | | | | | PROVIDE AN ELECTRICAL PLAN FOR THE RECONFIGURED LOGGIA. | | | RECEPTACLES ARE REQUIRED SO THAT AT NO POINT ALONG THE | | | FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A RECEPTACLE | | | OUTLET AND AT WALL SPACES 2 FEET OR MORE IN WIDTH. NEC | | | 210.52, FBC E3901.3 | | | | | | NOTE: THE PLANS ON SHEET A-OO2 INDICATE THE REMOVAL OF | | | APPLIANCES IN THE GARAGE. THESE APPLIANCES ARE STILL | | | SHOWN IN THE GARAGE ON THE ELECTRICAL PLANS. PLEASE | | | CLARIFY. | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6654(OFFICE) | | | 561-373-3701(CELL) | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-23 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-23 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2017-03-23 11:05:26 | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | ELECTRICAL REVIEW COMMENTS. | | | | | | PROVIDE AN ELECTRICAL PLAN FOR THE RECONFIGURED LOGGIA. | | | FBC E3901.3 | | | | | | VERIFY THAT THE EXISTING BEDROOMS HAVE THE REQUIRED | | | SMOKE AND CARBON MONOXIDE DETECTORS. REMODELING OF AN | | | EXISTING STRUCTURE IS REQUIRED TO INCLUDE | | | INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND OUTSIDE | | | EACH SLEEPING AREA. IF THE BUILDING HAS GAS APPLIANCES, | | | AN ATTACHED GARAGE OR A FIREPLACE, A CARBON MONOXIDE | | | DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH ROOM USED | | | FOR SLEEPING. 2014 FBC R314, 315 | | | | | | HIGH HAT CEILING LIGHTING FIXTURES IN INSULATED SPACES | | | NEED TO BE RATED FOR INSULATION CONTACT (IC). FBC | | | E4004.8 | | | | | | A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED | | | LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS OR A | | | MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING | | | FIXTURES SHALL CONTAIN HIGH EFFICIENCY LAMPS. FBC | | | ER404.1 | | | | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6654(OFFICE) | | | 561-373-3701(CELL) | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-27 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-16 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-11 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-04-04 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-03-16 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2017-04-04 14:02:59 | 4/4/17 PLACED IN DENIED H. IT IS ANTICIPATED THE | | | APPLICANT WILL REDUCE THE SCOPE OF THE APPLICATION, THE | | | ATTACHED CANCEL REQUEST ALSO INDICATES A SCOPE | | | REDUCTION. AN AMENDED LETTER IS FORTHCOMING. REVIEW IS | | | SUSPENDED UNTIL RE-SUBMITTAL. RE-SUBMITTAL MAY BE | | | ACCEPTED IF PRIOR TO 9/16/2017. SAK | | 2017-03-17 09:19:33 | R10 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-27 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-27 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-02 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-02 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2017-06-02 09:52:48 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. NO MECHANICAL PLAN SUBMITTED. CANNOT VERIFY | | | ADDITIONAL CONDITIONED SPACE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2017-06-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-06-26 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-06-26 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2017-06-26 15:40:25 | NO MECHANICAL WORK PROPOSED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-06-02 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-06-02 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2017-06-02 11:33:45 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | 1ST REVIEW FBC 2014 EXISTING BUILDING | | | | | | THE PLAN DOES NOT SHOW MECHANICAL IMPROVEMENTS HOWEVER | | | THE EXPANSION OF SPACE INDICATES MECHANICAL ALTERATIONS | | | MAY BE INDICATED. EITHER SUPPLY A PLAN PER THE SECTION | | | BELOW OR INDICATE NO MECHANICAL IS TO BE DONE UNDER THE | | | PROJECT OR WILL BE DONE BY SEPARATE PERMIT. | | | | | | FBC- 107.3.5.3 ? PROVIDE A MECHANICAL PLAN TO SHOW | | | SUPPLY DUCTS PER FBC-R M16 & | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-24 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-27 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-27 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-02 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2017-06-02 09:56:39 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW FLAT ROOF SYSTEM | | | COMPONENETS. | | | 2. PLANS SPECIFY "S" TYPE CLAY TILE TO BE USED FOR | | | REPLACEMENT OF MAIN HOUSE ROOFING. NOA SUBMITTED IS FOR | | | FLAT CONCRETE TILE. PLEASE CLARIFY. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
pcreigh |
Date |
2017-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-06-07 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|