| Plan Review Stops For Permit 17030449 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-26 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-26 |
Time |
06:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-12 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-05-12 07:51:59 | BLDG. # 3. PLANS WILL NOT BE STAMPED UNTIL ALL 3 | | | BUILDINGS CAN MEET CODE COMPLIANCE. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-18 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-18 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2017-03-18 11:56:49 | BLDG. # 3. PLANS WILL NOT BE STAMPED UNTIL ALL 3 | | | BUILDINGS CAN MEET CODE COMPLIANCE. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-31 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-31 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-14 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-14 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-06-06 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-06-06 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2017-06-06 11:10:49 | 1851 DIVISION AVENUE | | | TRACKING #17030449 | | | PERMIT #15050262 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 06/14/17 UPDATE: PROJECT TEAM HAS AGREED (PER PHONE | | | CONVERSATION) TO SUBMIT ALL APPROPRIATE DECORATIVE GAS | | | FIREPLACE LISTING AND INSTALLATION INFORMATION FOR FIRE | | | DEPARTMENT APPROVAL PRIOR TO INSTALLATION. | | | | | | | | | PREVIOUS REVIEW COMMENTS NOT ADDRESSED: | | | REPEAT COMMENT - SUBMIT EQUIPMENT SPECIFICATIONS, | | | LISTING INFORMATIN AND INSTALLATION INFORMATION FOR THE | | | FIREPLACE APPLIANCE. | | | | | | REPEAT COMMENT - INDICATE IF THE FIREPLACE IS A | | | CATEGORY I, II, III OR IV VENTED APPLIANCE IN | | | ACCORDANCE WITH NFPA 54. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-03-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-03-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-03-22 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2017-03-22 16:11:49 | 1851 DIVISION AVENUE | | | TRACKING #17030449 | | | PERMIT #15050262 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SUBMIT EQUIPMENT SPECIFICATIONS, LISTING INFORMATIN AND | | | INSTALLATION INFORMATION FOR THE FIREPLACE APPLIANCE. | | | | | | INDICATE IF THE FIREPLACE IS A CATEGORY I, II, III OR | | | IV VENTED APPLIANCE IN ACCORDANCE WITH NFPA 54. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-11 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-11 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-12 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2017-04-12 14:44:54 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. PLEASE PROVIDE COMBUSTION AIR CALCULATIONS FOR FIRE | | | PLACE. PER FBC FG 304 | | | | | | 2. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 4. SUBMIT MANUFACTURE INSTILLATION GUIDE FOR THE FIRE | | | PLACE VENT. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHT. P-4.05 THE TOTAL BTU LOAD IS LISTED AS | | | 4,650,000 BTUS BUT WHEN I COUNTED UP THE WH I CAME UP | | | WITH 33 @ 150,00 = 4,950,000 BTUS PLEASE CLARIFY. WPB | | | AMEND TO FBC 107.2.1 | | | | | | 6. SHT. P-4.06 THE TOTAL BTU LOAD IS LISTED AS | | | 4,850,000 BTUS BUT WHEN I COUNTED UP THE WH I CAME UP | | | WITH 35 @ 150,00 = 5,250,000 BTUS PLEASE CLARIFY. WPB | | | AMEND TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-06-06 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-05-22 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-23 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-02 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2017-05-02 12:11:20 | C34 FEES NEED TO BE PAID. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-10 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-30 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-30 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2017-05-30 11:52:29 | MECHANICAL PROVISOS | | | 5/30/17 | | | | | | 1) CLOTHES DRYER EXHAUST DUCTS SHALL NOT EXTEND INTO OR | | | THROUGH DUCTS OR PLENUMS- SECTION 504.4 FBC-14 | | | MECHANICAL. | | | | | | 2) GAS WATER HEATERS AND VENTS: | | | 503.3.5 AIR DUCTS AND FURNACE PLENUMS. | | | VENTING SYSTEMS SHALL NOT EXTEND INTO OR PASS THROUGH | | | ANY FABRICATED AIR DUCT OR FURNACE PLENUM. | | | | | | 503.3.6 ABOVE-CEILING AIR-HANDLING SPACES. | | | WHERE A VENTING SYSTEM PASSES THROUGH AN ABOVE-CEILING | | | AIR-HANDLING SPACE OR OTHER NONDUCTED PORTION OF AN | | | AIR-HANDLING SYSTEM, THE VENTING SYSTEM SHALL CONFORM | | | TO ONE OF THE FOLLOWING REQUIREMENTS: | | | | | | 1. THE VENTING SYSTEM SHALL BE A LISTED SPECIAL GAS | | | VENT; OTHER VENTING SYSTEM SERVING A CATEGORY III OR | | | CATEGORY IV APPLIANCE; OR OTHER POSITIVE PRESSURE VENT, | | | WITH JOINTS SEALED IN ACCORDANCE WITH THE APPLIANCE OR | | | VENT MANUFACTURER?S INSTRUCTIONS. | | | | | | 2. THE VENTING SYSTEM SHALL BE INSTALLED SUCH THAT | | | FITTINGS AND JOINTS BETWEEN SECTIONS ARE NOT INSTALLED | | | IN THE ABOVE-CEILING SPACE. | | | | | | 3. THE VENTING SYSTEM SHALL BE INSTALLED IN A CONDUIT | | | OR ENCLOSURE WITH SEALED JOINTS SEPARATING THE INTERIOR | | | OF THE CONDUIT OR ENCLOSURE FROM THE CEILING SPACE. | | | | | | 3) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE GAS FIREPLACE AND VENTING IN THE | | | CLUBROOM SHALL BE ONSITE AT TIME OF INSPECTION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-08 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-08 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2017-05-08 15:25:27 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030449 | | | 5/8/17 | | | | | | RESULT: DENIED | | | | | | 1) THE REQUESTED MANUFACTURER'S SPECIFICATIONS FOR THE | | | NEW GAS FIREPLACE AND VENTING SYSTEM WERE NOT | | | SUBMITTED- PLEASE COMPLY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-20 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-20 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2017-03-20 09:54:41 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030449 | | | 3/20/17 | | | | | | 1) SHEET M-100B: A NEW AC SYSTEM- AC-4A IS SHOWN. | | | PLEASE ADD THE SYSTEM TO THE AC EQUIPMENT SCHEDULE ON | | | SHEET M-300. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-06 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-06 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-11 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-11 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-04-12 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-12 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2017-04-12 14:22:17 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. IT IS UNCLEAR WHAT PLUMBING IS BEING REVISED PLEASE | | | CLOUD ALL REVISIONS ON THE PLAN AND PROVIDE A NARRATIVE | | | THAT LIST THE PAGE NUMBERS AND REVISION NUMBER AND WHAT | | | IS BE REVISED. PER WPB AMEND. TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-06-06 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-06-06 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2017-06-06 16:04:15 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.06.2017 | | | PERMIT NO.: 15050261, 15050262, AND 15050263 | | | ADDRESS: 838 ADAMS STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW MULTIFAMILY DEVELOPMENT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS SHALL BE OBTAINED FOR THE | | | FOLLOWING: I) FENCING/WALLS, II) LANDSCAPING, AND III) | | | IRRIGATION. | | | | | | 2. PRIOR TO THE INSTALLATION OF ANY SITE LIGHTING, THE | | | LIGHTING PLAN SHALL BE REVISED TO REFLECT PHOTOMETRIC | | | LEVELS NOT EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED AT | | | THE PROPERTY LINE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-03-29 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-03-29 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2017-03-29 15:09:41 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.29.2017 | | | PERMIT NO.: 15050261, 15050262, AND 15050263 | | | ADDRESS: 838 ADAMS STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW MULTIFAMILY DEVELOPMENT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS SHALL BE OBTAINED FOR THE | | | FOLLOWING: I) FENCING/WALLS, II) LANDSCAPING, AND III) | | | IRRIGATION. | | | | | | 2. PRIOR TO THE INSTALLATION OF ANY SITE LIGHTING, THE | | | LIGHTING PLAN SHALL BE REVISED TO REFLECT PHOTOMETRIC | | | LEVELS NOT EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED AT | | | THE PROPERTY LINE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|