| Plan Review Stops For Permit 17030448 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-26 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-26 |
Time |
06:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-12 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-12 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2017-05-12 07:48:40 | BUILDING PLAN REVIEW | | | SILVER PALM PLACE | | | BLDG # 1/ 66 UNITS/ 4 STORY/ R2/ 2010 TYPE I-B | | | W. P. B. REVISION: 17030448 | | | W. P. B. PERMIT: 15050261 | | | ADD: 838 ADAMS ST. | | | CONT: LANDMARK CONSTRUCTION | | | CONTACT: CHARLES ROBERSON | | | TEL: 305-665-1146 | | | E-MAIL: ?????? | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND REVIEW | | | DATE: FRI. MAY 12/2017 | | | SILVER PALM PLACE | | | BLDG # 1/ 66 UNITS/ 4 STORY/ R2 | | | | | | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2A) 2ND REQUEST. SHEET A-3.00 NOTES 6 & 10 INDICATE THE | | | USE OF PRE-FABRICATED DECORATIVE FOAM OUTLOOKERS AT | | | ELEVATION 46FOOT ? 8INCHES. IT HAS RECENTLY BROUGHT TO | | | MY ATTENTION THAT FOR FOAM (EFIS) THE CODE SECTION | | | 1406.2 EXCEPTION: PLASTIC COMPLYING WITH CHAPTER 26. IN | | | CHAPTER 26 EFIS. THE EFIS TRIM WILL NEED TO SHOW | | | COMPLIANCE WITH 2603.5. EXTERIOR WALLS OF BUILDINGS OF | | | TYPE I, II, III OR IV CONSTRUCTION OF ANY HEIGHT SHALL | | | COMPLY WITH SECTIONS 2603.5.1 THROUGH 2603.5.7. | | | SATISFYING THIS COMMENT ELIMINATES COMMENTS 2B-2E. | | | | | | COMMENTS FROM 1ST REVIEW. PLEASE REVIEW IN THE 2010 | | | FBC-B SECTION 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR WALL | | | COVERINGS SHALL BE LIMITED TO 40 FEET (12 192 MM) IN | | | HEIGHT ABOVE GRADE PLANE. IN THE 2009 IBC-B COMMENTARY | | | IT STATES: ALL EXTERIOR TRIM AND VENEERS ON BUILDINGS | | | OF TYPE I, II III AND IV CONSTRUCTION THAT ARE MORE | | | THAN 40 FEET ABOVE THE GRADE ARE REQUIRED TO BE | | | NON-COMBUSTIBLE. | | | | | | | | | 2B) PLEASE IDENTIFY WHERE THE USE OF THE SMOOTH FOAM | | | BRACKETS ARE TO BE LOCATED ON THE BUILDING SEE NOTE | | | NUMBER 10. THE 2010 FBC-B SECTION 1406.2.1 (2) 2. | | | COMBUSTIBLE EXTERIOR WALL COVERINGS SHALL BE LIMITED TO | | | 40 FEET (12 192 MM) IN HEIGHT ABOVE GRADE PLANE. | | | | | | 2C) SHEET A-3.00 NOTE 17 STATES PRE-FABRICATED | | | DECORATIVE BRACKETS BUT THE PLANS DO NOT SPECIFY THE | | | TYPE OF MATERIALS. ELEVATION A DOES SHOW THE USE OF | | | DECORATIVE BRACKET TYPE 17 ABOVE 40 FEET ABOVE GRADE. | | | 2010 FBC-B SECTION 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR | | | WALL COVERINGS SHALL BE LIMITED TO 40 FEET (12 192 MM) | | | IN HEIGHT ABOVE GRADE PLANE. | | | | | | | | | 2D) SHEET A-3.04 DETAIL 10 FOAM BRACKET AT ROOF LINE | | | THE DIMENSIONS INDICATED AND THE SCALE 1 INCH = 1 FOOT | | | DOES NOT MATCH UP? PLEASE PROVIDE ADDITIONAL | | | INFORMATION. 107.2.1.3. | | | | | | 2E) SHEET A-4.2 DETAILS 2 & 3 BOTH SHOW THE USE OF FOAM | | | BRACKETS ABOVE THE 40 FOOT FROM GRADE LEVEL. 2010 FBC-B | | | SECTION 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR WALL | | | COVERINGS SHALL BE LIMITED TO 40 FEET (12 192 MM) IN | | | HEIGHT ABOVE GRADE PLANE. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-18 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-18 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2017-03-18 11:49:11 | | | | BUILDING PLAN REVIEW | | | SILVER PALM PLACE | | | BLDG # 1/ 66 UNITS/ 4 STORY/ R2/ 2010 TYPE I-B | | | W. P. B. REVISION: 17030448 | | | W. P. B. PERMIT: 15050261 | | | ADD: 838 ADAMS ST. | | | CONT: LANDMARK CONSTRUCTION | | | CONTACT: CHARLES ROBERSON | | | TEL: 305-665-1146 | | | E-MAIL: ?????? | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: SAT. MARCH 18/2017 | | | SILVER PALM PLACE | | | BLDG # 1/ 66 UNITS/ 4 STORY/ R2 | | | | | | 1) PLEASE PROVIDE YOUR E-MAIL ADDRESS; WE USE YOUR | | | E-MAIL ADDRESS FOR CORRESPONDENCE IN THE FORM OF A | | | WRITTEN RECORD. 107.2.1.4 THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR | | | RECORD RETENTION PROGRAM. | | | | | | 2A) SHEET A-3.00 NOTES 6 & 10 INDICATE THE USE OF | | | PRE-FABRICATED DECORATIVE FOAM OUTLOOKERS AT ELEVATION | | | 46?-8?. PLEASE REVIEW IN THE 2010 FBC-B SECTION | | | 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR WALL COVERINGS | | | SHALL BE LIMITED TO 40 FEET (12 192 MM) IN HEIGHT ABOVE | | | GRADE PLANE. IN THE 2009 IBC-B COMMENTARY IT STATES: | | | ALL EXTERIOR TRIM AND VENEERS ON BUILDINGS OF TYPE I, | | | II III AND IV CONSTRUCTION THAT ARE MORE THAN 40 FEET | | | ABOVE THE GRADE ARE REQUIRED TO BE NON-COMBUSTIBLE. | | | | | | 2B) PLEASE IDENTIFY WHERE THE USE OF THE SMOOTH FOAM | | | BRACKETS ARE TO BE LOCATED ON THE BUILDING SEE NOTE | | | NUMBER 10. THE 2010 FBC-B SECTION 1406.2.1 (2) 2. | | | COMBUSTIBLE EXTERIOR WALL COVERINGS SHALL BE LIMITED TO | | | 40 FEET (12 192 MM) IN HEIGHT ABOVE GRADE PLANE. | | | | | | 2C) SHEET A-3.00 NOTE 17 STATES PRE-FABRICATED | | | DECORATIVE BRACKETS BUT THE PLANS DO NOT SPECIFY THE | | | TYPE OF MATERIALS. ELEVATION A DOES SHOW THE USE OF | | | DECORATIVE BRACKET TYPE 17 ABOVE 40 FEET ABOVE GRADE. | | | 2010 FBC-B SECTION 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR | | | WALL COVERINGS SHALL BE LIMITED TO 40 FEET (12 192 MM) | | | IN HEIGHT ABOVE GRADE PLANE. | | | | | | | | | 2D) SHEET A-3.04 DETAIL 10 FOAM BRACKET AT ROOF LINE | | | THE DIMENSIONS INDICATED AND THE SCALE 1 INCH = 1 FOOT | | | DOES NOT MATCH UP? PLEASE PROVIDE ADDITIONAL | | | INFORMATION. 107.2.1.3. | | | | | | 2E) SHEET A-4.2 DETAILS 2 & 3 BOTH SHOW THE USE OF FOAM | | | BRACKETS ABOVE THE 40 FOOT FROM GRADE LEVEL. 2010 FBC-B | | | SECTION 1406.2.1 (2) 2. COMBUSTIBLE EXTERIOR WALL | | | COVERINGS SHALL BE LIMITED TO 40 FEET (12 192 MM) IN | | | HEIGHT ABOVE GRADE PLANE. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-31 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-31 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-14 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-14 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-06-06 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-06-06 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2017-06-06 11:12:49 | 838 ADAMS STREET | | | TRACKING #17030448 | | | PERMIT #15050261 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | 06/14/17 UPDATE: PROJECT TEAM HAS AGREED (PER PHONE | | | CONVERSATION) TO SUBMIT ALL APPROPRIATE DECORATIVE GAS | | | FIREPLACE LISTING AND INSTALLATION INFORMATION FOR FIRE | | | DEPARTMENT APPROVAL PRIOR TO INSTALLATION. | | | | | | | | | PREVIOUS REVIEW COMMENTS NOT ADDRESSED: | | | REPEAT COMMENT - SUBMIT EQUIPMENT SPECIFICATIONS, | | | LISTING INFORMATIN AND INSTALLATION INFORMATION FOR THE | | | FIREPLACE APPLIANCE. | | | | | | REPEAT COMMENT - INDICATE IF THE FIREPLACE IS A | | | CATEGORY I, II, III OR IV VENTED APPLIANCE IN | | | ACCORDANCE WITH NFPA 54. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-05 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-05 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2017-06-05 17:24:39 | GAS PROVISO : | | | | | | 1. MANUFACTURE SPECS AND INSTALLATION GUIDE SHALL BE ON | | | JOBSITE FOR INSPECTION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-11 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-11 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2017-05-11 09:38:50 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | PREVIOUS COMMENTS HAVE NOT BEEN COMPLIED WITH.THE | | | RESPONSE LETTER STATES THEY WERE ATTACHED I COULD NOT | | | LOCATE THEM. | | | | | | 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 4. SUBMIT MANUFACTURE INSTILLATION GUIDE FOR THE FIRE | | | PLACE VENT. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-12 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2017-04-12 14:56:27 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GASCOMMENTS: | | | | | | 1. PLEASE PROVIDE COMBUSTION AIR CALCULATIONS FOR FIRE | | | PLACE. PER FBC FG 304 | | | | | | 2. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 4. SUBMIT MANUFACTURE INSTILLATION GUIDE FOR THE FIRE | | | PLACE VENT. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHT. P-4.05 THE TOTAL BTU LOAD IS LISTED AS | | | 4,650,000 BTUS BUT WHEN I COUNTED UP THE WH I CAME UP | | | WITH 33 @ 150,00 = 4,950,000 BTUS PLEASE CLARIFY. WPB | | | AMEND TO FBC 107.2.1 | | | | | | 6. SHT. P-4.06 THE TOTAL BTU LOAD IS LISTED AS | | | 4,850,000 BTUS BUT WHEN I COUNTED UP THE WH I CAME UP | | | WITH 35 @ 150,00 = 5,250,000 BTUS PLEASE CLARIFY. WPB | | | AMEND TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-06-06 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-05-22 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-12 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-02 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2017-05-02 12:10:18 | C34 FEES NEED TO BE PAID. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-12 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-10 |
Time |
17:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-30 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-30 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2017-05-30 11:51:55 | MECHANICAL PROVISOS | | | 5/30/17 | | | | | | 1) CLOTHES DRYER EXHAUST DUCTS SHALL NOT EXTEND INTO OR | | | THROUGH DUCTS OR PLENUMS- SECTION 504.4 FBC-14 | | | MECHANICAL. | | | | | | 2) GAS WATER HEATERS AND VENTS: | | | 503.3.5 AIR DUCTS AND FURNACE PLENUMS. | | | VENTING SYSTEMS SHALL NOT EXTEND INTO OR PASS THROUGH | | | ANY FABRICATED AIR DUCT OR FURNACE PLENUM. | | | | | | 503.3.6 ABOVE-CEILING AIR-HANDLING SPACES. | | | WHERE A VENTING SYSTEM PASSES THROUGH AN ABOVE-CEILING | | | AIR-HANDLING SPACE OR OTHER NONDUCTED PORTION OF AN | | | AIR-HANDLING SYSTEM, THE VENTING SYSTEM SHALL CONFORM | | | TO ONE OF THE FOLLOWING REQUIREMENTS: | | | | | | 1. THE VENTING SYSTEM SHALL BE A LISTED SPECIAL GAS | | | VENT; OTHER VENTING SYSTEM SERVING A CATEGORY III OR | | | CATEGORY IV APPLIANCE; OR OTHER POSITIVE PRESSURE VENT, | | | WITH JOINTS SEALED IN ACCORDANCE WITH THE APPLIANCE OR | | | VENT MANUFACTURER?S INSTRUCTIONS. | | | | | | 2. THE VENTING SYSTEM SHALL BE INSTALLED SUCH THAT | | | FITTINGS AND JOINTS BETWEEN SECTIONS ARE NOT INSTALLED | | | IN THE ABOVE-CEILING SPACE. | | | | | | 3. THE VENTING SYSTEM SHALL BE INSTALLED IN A CONDUIT | | | OR ENCLOSURE WITH SEALED JOINTS SEPARATING THE INTERIOR | | | OF THE CONDUIT OR ENCLOSURE FROM THE CEILING SPACE. | | | | | | 3) MANUFACTURER'S SPECIFICATIONS AND INSTALLATION | | | INSTRUCTIONS FOR THE GAS FIREPLACE AND VENTING IN THE | | | CLUBROOM SHALL BE ONSITE AT TIME OF INSPECTION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-08 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-08 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2017-05-08 15:24:44 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030448 | | | 5/8/17 | | | | | | RESULT: DENIED | | | | | | 1) THE REQUESTED MANUFACTURER'S SPECIFICATIONS FOR THE | | | NEW GAS FIREPLACE AND VENTING SYSTEM WERE NOT | | | SUBMITTED- PLEASE COMPLY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-20 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-20 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2017-03-20 09:53:57 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030448 | | | 3/20/17 | | | | | | 1) SHEET M-100B: A NEW AC SYSTEM- AC-4A IS SHOWN. | | | PLEASE ADD THE SYSTEM TO THE AC EQUIPMENT SCHEDULE ON | | | SHEET M-300. | | | | | | 2) M-2.02: SUBMIT MANUFACTURER'S SPECIFCATIONS FOR THE | | | GAS FIREPLACE AND VENT SYSTEM, AND INDICATE HOW | | | CIOMBUSTION AIR IS BEING PROVIDED PER SECTION 304 FUEL | | | GAS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-05 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-05 |
Time |
17:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-11 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2017-05-11 09:35:16 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHTS. P- 2.00, 2.01, 2.02, 2.03, 2.04, 2.05 ARE | | | DRAWN TO SMALL I HAD TO USE A MAGNIFYING GLASS TO READ | | | COMBUSTION AIR CALCULATIONS ALL DRAWING SHALL BE A MIN | | | OF 1/8" PER FT. WPB AMEND TO FBC 107.2.1.4 QUALITY OF | | | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A | | | MINIMUM 1/8 INCH | | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | | MEDIUM. THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS | | | FOR PLANS AND SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | | THE ARCHIVE REQUIREMENTS OF | | | FLORIDA STATUTES. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-04-12 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-12 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2017-04-12 14:53:54 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. IT IS UNCLEAR WHAT PLUMBING IS BEING REVISED PLEASE | | | CLOUD ALL REVISIONS ON THE PLAN AND PROVIDE A NARRATIVE | | | THAT LIST THE PAGE NUMBERS AND REVISION NUMBER AND WHAT | | | IS BE REVISED. PER WPB AMEND. TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-06-06 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-06-06 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2017-06-06 16:03:14 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.06.2017 | | | PERMIT NO.: 15050261, 15050262, AND 15050263 | | | ADDRESS: 838 ADAMS STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW MULTIFAMILY DEVELOPMENT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS SHALL BE OBTAINED FOR THE | | | FOLLOWING: I) FENCING/WALLS, II) LANDSCAPING, AND III) | | | IRRIGATION. | | | | | | 2. PRIOR TO THE INSTALLATION OF ANY SITE LIGHTING, THE | | | LIGHTING PLAN SHALL BE REVISED TO REFLECT PHOTOMETRIC | | | LEVELS NOT EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED AT | | | THE PROPERTY LINE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-03-29 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-03-29 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2017-03-29 15:10:46 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.29.2017 | | | PERMIT NO.: 15050261, 15050262, AND 15050263 | | | ADDRESS: 838 ADAMS STREET | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW MULTIFAMILY DEVELOPMENT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. SEPARATE PERMITS SHALL BE OBTAINED FOR THE | | | FOLLOWING: I) FENCING/WALLS, II) LANDSCAPING, AND III) | | | IRRIGATION. | | | | | | 2. PRIOR TO THE INSTALLATION OF ANY SITE LIGHTING, THE | | | LIGHTING PLAN SHALL BE REVISED TO REFLECT PHOTOMETRIC | | | LEVELS NOT EXCEEDING 0.5 FOOTCANDLES WHEN MEASURED AT | | | THE PROPERTY LINE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|