| 2017-04-12 08:58:51 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE |
| | THEIR PRINTED NAME AND SIGNATURE ON THE SUBMITTED PLANS |
| | AND SUPPORTING DOCUMENTS PER FBC 107. |
| | 1. ADDRESS ZONING SETBACK REQUIREMENTS. |
| | 2. FOUNDATION - SPECIFY FOOTING RE-INFORCEMENT (MIN. 1 |
| | - #8 CONT.) |
| | 3. FRAMING - PROVIDE DETAIL, SHOW WALL STUD SPACING, |
| | STUCCO ASSEMBLY AND UPLIFT CONNECTORS FOR WALL TO ROOF |
| | CONNECTION. |
| | 4. ROOF FRAMING - PROVIDE FASTENER SCHEDULE FOR ROOF |
| | SHEATHING BASED ON DESIGN WIND LOADS. |
| | 5. PROVIDE DESIGN WIND LOADS FOR EXT. WALL CLADDING AND |
| | OPENINGS. |
| | 6. PROVIDE PRODUCT APPROVALS FOR ROOFING. |
| | 7. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND DOORS. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY |
| | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING, |
| | WINDOW, AND DOOR SUBMITTALS. |
| | |
| | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN |
| | PRESSURES PURSUANT TO FBC-R301.2. |
| | |
| | R301.2.1 WIND DESIGN CRITERIA. |
| | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN |
| | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING |
| | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED |
| | FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF |
| | THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND |
| | DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1. |
| | WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL |
| | MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING, |
| | THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH |
| | PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE |
| | WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR |
| | HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED |
| | TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR |
| | WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR |
| | WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN |
| | GARAGE DOORS). WHERE LOADS FOR GARAGE DOORS ARE NOT |
| | OTHERWISE SPECIFIED, THE LOADS LISTED IN TABLE |
| | R301.2(4) ADJUSTED FOR HEIGHT AND EXPOSURE USING TABLE |
| | R301.2(3) SHALL BE USED TO DETERMINE DESIGN LOAD |
| | PERFORMANCE REQUIREMENTS. ASPHALT SHINGLES SHALL BE |
| | DESIGNED FOR WIND SPEEDS IN ACCORDANCE WITH SECTION |
| | R905.2.4. A CONTINUOUS LOAD PATH SHALL BE PROVIDED TO |
| | TRANSMIT THE APPLICABLE UPLIFT FORCES IN SECTION R802.2 |
| | FROM THE ROOF ASSEMBLY TO THE FOUNDATION. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |