Plan Review Details - Permit 17030410
| Plan Review Stops For Permit 17030410 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-03-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-30 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-30 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-23 |
Time |
14:22 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-04-04 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-04-04 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-04-04 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-16 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-16 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-11 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-28 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-23 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-10 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-04-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-11 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-10 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-16 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-23 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2017-03-16 14:49:33 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE WATER AND SANITARY RISERS. PER WPB | | | AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. THE TANKLESS WATER HEATER THAT IS SPEC OUT ON THE | | | PLAN IS RATED FOR A SINGLE SINK PER MANUFACTURE A | | | LARGER HEATER WILL BE REQUIRED FOR BOTH THE SINK AND | | | WASHING MACHINE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE WASHER AND DRYER SHALL COMPLY WITH FBC ACC 611 | | | WASHING MACHINES AND CLOTHES DRYERS | | | | | | 611.1 GENERAL. | | | WASHING MACHINES AND CLOTHES DRYERS SHALL COMPLY WITH | | | 611. | | | | | | 611.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 | | | POSITIONED FOR PARALLEL APPROACH SHALL BE PROVIDED. THE | | | CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE | | | APPLIANCE. | | | | | | 611.3 OPERABLE PARTS. | | | OPERABLE PARTS, INCLUDING DOORS, LINT SCREENS, AND | | | DETERGENT AND BLEACH COMPARTMENTS SHALL COMPLY WITH | | | 309. | | | | | | 611.4 HEIGHT. | | | TOP LOADING MACHINES SHALL HAVE THE DOOR TO THE LAUNDRY | | | COMPARTMENT LOCATED 36 INCHES (915 MM) MAXIMUM ABOVE | | | THE FINISH FLOOR. FRONT LOADING MACHINES SHALL HAVE THE | | | BOTTOM OF THE OPENING TO THE LAUNDRY COMPARTMENT | | | LOCATED 15 INCHES (380 MM) MINIMUM AND 36 INCHES (915 | | | MM) MAXIMUM ABOVE THE FINISH FLOOR. | | | | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy