Plan Review Details - Permit 17030312
| Plan Review Stops For Permit 17030312 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-20 |
Time |
06:45 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-03-20 |
Time |
06:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-30 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-30 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2017-03-16 12:48:32 | PLANS ISSUED WITH THE FOLLOWING: | | | | | | | | | PROVISO: | | | | | | PROVIDE A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | FOR THE SERVICE, PANEL BOARDS AND MAIN DISCONNECTING | | | MEANS. NEC 110.16, 110.22, 110.24 | | | | | | PROVIDE INTERIOR LIGHTING CALCULATION SHOWING | | | COMPLIANCE WITH THE FLORIDA BUILDING CODE ENERGY | | | CONSERVATION REQUIREMENTS. FBC C405.5.2 | | | | | | ROBERT LECKY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6654 | | | 561-373-3701 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-14 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2017-03-14 16:01:06 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) | | | SHEET G101 - THERE IS NO INDICATIONS REGARDING EXISTING | | | LIFE SAFETY SYSTEMS. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | PLEASE ENSURE ALL WORK IS PROPERLY SUBMITTED FOR | | | PERMIT. | | | | | | | | | | | | 2) | | | SHEET E101 - THERE ARE CARD READERS AND STRIKE PLATES | | | INDICATED. | | | | | | ALL CARD READER AND STRIKE PLATE WORK SHALL BE | | | SUBMITTED UNDER SEPARATE SHOP DRAWINGS. | | | | | | | | | | | | 3) | | | SHEET 201 - THRE ARE FIRE ALARM DEVICE/EQUIPMENT | | | INDICATED. | | | | | | THE FIRE ALARM SYSTEM SHALL REMAIN ACTIVE THROUGHOUT | | | THE CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM SHALL BE DONE UNDER | | | SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-03-30 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2017-03-30 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-30 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2017-03-30 12:59:27 | ADDED PROVISO TO ELECTRIC REVIEW. RL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-03-20 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-03-08 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-20 |
Time |
06:45 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-03-20 |
Time |
06:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-20 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-20 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2017-03-20 11:59:32 | MECHANICAL PROVISO: | | | 3/20/17 | | | | | | 1) PROVIDE A PLAN SHOWING THE LOCATION OF THE CONDENSER | | | (CU-14-7) AND SUBMIT THE MIAMI-DADE NOA FOR THE STAND | | | WITH ALL APPLICABLE INSTALLATION NOTES AND DETAILS | | | MARKED BY THE E.O.R. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-03-20 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-03-20 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
|