Plan Review Details - Permit 17030265
Plan Review Stops For Permit 17030265
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-03-31 Cont ID  
Sent By cthroop Date 2017-03-31 Time 10:13 Rev Time 0.00
Received By cthroop Date 2017-03-31 Time 09:54 Sent To  
Notes
2017-03-31 10:14:40TRAVELING WITH 17030939. SENT TO E (VP).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-16 Cont ID  
Sent By cthroop Date 2017-03-16 Time 12:28 Rev Time 0.00
Received By cthroop Date 2017-03-16 Time 11:45 Sent To  
Notes
2017-03-16 12:31:47BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PREVIOUS APPLICATION # 16010004 - CHANGE OF
 USE/OCCUPANCY FROM DOCTOR'S OFFICE TO TEMPORARY FIRE
 STATION #9 HAS EXPIRED.
 2. IT WAS RECOMMENDED TO HAVE A DESIGN PROFESSIONAL
 SUBMIT PLANS. NO PLANS ON FILE,
 3. LIFE SAFETY ISSUES WERE NEVER ADDRESSED: SMOKE
 ALARMS, FIRE ALARM, ADDITIONAL EXIT SIGN.
 4. THIS CURRENT APPLICATION IS FOR THE RENOVATION OF
 ACCESSIBLE TOILET ROOM #2: INSTALLATION OF A NEW
 SHOWER.
 4A. CANNOT VERIFY SHOWER OR ROOM COMPLIES WITH THE
 ACCESSIBILITY CODE. INSUFFICIENT INFORMATION ON PLAN:
 CLEAR FLOOR SPACE, GRAB BARS, CONTROLS LOCATION,
 ROLL-IN ACCESS, ETC.
  
 SECTION 111 CERTIFICATE OF OCCUPANCY
 [A] 111.1 USE AND OCCUPANCY.
 NO BUILDING OR STRUCTURE SHALL BE USED OR OCCUPIED, AND
 NO CHANGE IN THE EXISTING OCCUPANCY CLASSIFICATION OF A
 BUILDING OR STRUCTURE OR PORTION THEREOF SHALL BE MADE,
 UNTIL THE BUILDING OFFICIAL HAS ISSUED A CERTIFICATE OF
 OCCUPANCY THEREFOR AS PROVIDED HEREIN. ISSUANCE OF A
 CERTIFICATE OF OCCUPANCY SHALL NOT BE CONSTRUED AS AN
 APPROVAL OF A VIOLATION OF THE PROVISIONS OF THIS CODE
 OR OF OTHER ORDINANCES OF THE JURISDICTION.
  
 SECTION 108 TEMPORARY STRUCTURES AND USES
 [A] 108.1 GENERAL.
 THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT
 FOR TEMPORARY STRUCTURES AND TEMPORARY USES. SUCH
 PERMITS SHALL BE LIMITED AS TO TIME OF SERVICE, BUT
 SHALL NOT BE PERMITTED FOR MORE THAN 180 DAYS. THE
 BUILDING OFFICIAL IS AUTHORIZED TO GRANT EXTENSIONS FOR
 DEMONSTRATED CAUSE.
  
 603 TOILET AND BATHING ROOMS
 603.1 GENERAL.
 TOILET AND BATHING ROOMS SHALL COMPLY WITH 603.
 603.2 CLEARANCES.
 CLEARANCES SHALL COMPLY WITH 603.2.
 603.2.1 TURNING SPACE.
 TURNING SPACE COMPLYING WITH 304 SHALL BE PROVIDED
 WITHIN THE ROOM.
 603.2.2 OVERLAP.
 REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES, AND
 TURNING SPACE SHALL BE PERMITTED TO OVERLAP.
 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-03-29 Cont ID  
Sent By jleahy Date 2017-03-29 Time 10:51 Rev Time 0.00
Received By jleahy Date 2017-03-29 Time 10:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-03-17 Cont ID  
Sent By jleahy Date 2017-03-15 Time 07:41 Rev Time 0.00
Received By jleahy Date 2017-03-15 Time 07:41 Sent To  
Notes
2017-03-17 08:14:56NO ELECTRICAL WORK SHOWN, NEED A DETAILED PLAN SHOWING
 ELECTRICAL WORK BEING PERFORMED. JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-03-28 Cont ID  
Sent By pleduc Date 2017-03-28 Time   Rev Time 0.00
Received By pleduc Date 2017-03-28 Time 14:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2017-03-09 Cont ID  
Sent By wjolin Date 2017-03-09 Time 14:43 Rev Time 0.00
Received By wjolin Date 2017-03-09 Time 14:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-10 Cont ID  
Sent By cpuell Date 2017-04-10 Time 14:59 Rev Time 0.00
Received By cpuell Date 2017-04-03 Time 13:18 Sent To  
Notes
2017-04-03 13:19:01PER RBROWN, ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-31 Cont ID  
Sent By cthroop Date 2017-03-31 Time 10:13 Rev Time 0.00
Received By cthroop Date 2017-03-23 Time 14:06 Sent To  
Notes
2017-03-27 14:07:00B06 - TRAVELLING WITH CHANGE OF OCCUPANY PERMIT
 17030939

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-16 Cont ID  
Sent By cthroop Date 2017-03-16 Time 12:28 Rev Time 0.00
Received By cthroop Date 2017-03-07 Time 13:07 Sent To  
Notes
2017-03-08 13:07:13B02

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-06-08 Cont ID  
Sent By skennedy Date 2017-06-08 Time 16:09 Rev Time 0.00
Received By skennedy Date 2017-06-08 Time 16:08 Sent To  
Notes
2017-06-08 16:09:26FOR DRYER VENT ONLY, SUBJECT TO INSPECTOR.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-03-30 Cont ID  
Sent By gjohnson Date 2017-03-30 Time 17:52 Rev Time 0.00
Received By gjohnson Date 2017-03-30 Time 16:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-03-16 Cont ID  
Sent By gjohnson Date 2017-03-16 Time 08:48 Rev Time 0.00
Received By gjohnson Date 2017-03-15 Time 14:52 Sent To  
Notes
2017-03-16 09:38:541ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. ELIMINATING THE TOILET MAY BRING THE REQUIRED
 FIXTURE COUNT BELOW THE NUMBER REQUIRED FOR THIS
 OCCUPANCY TYPE AND OCCUPANT LOAD. PER FBC PL TABLE
 403.1 PLEASE PROVIDE OCCUPANT LOAD AND FIXTURE COUNT
 FOR SPACE. PER WPB AMEND TO FBC 107.2.1
  
 2. PLEASE PROVIDE RISER DIAGRAM FOR NEW WASHING
 MACHINE. PER WPB AMEND 107.3.5.1.3(13)
  
 3. SHOW ACCESSIBILITY REQUIREMENTS FOR NEW SHOWER. PER
 FBC ACC 213.3.6 BATHING FACILITIES.
 WHERE BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE
 BATHTUB COMPLYING WITH 607 OR AT LEAST ONE SHOWER
 COMPLYING WITH 608 SHALL BE PROVIDED.
  
 4. ADA BATH #1 DOES NOT COMPLY WITH FBC ACC
 604.3.1 SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL.
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-04-10 Cont ID  
Sent By llouie Date 2017-04-10 Time   Rev Time 0.00
Received By llouie Date 2017-04-10 Time   Sent To I
Notes
2017-04-10 13:59:47- USE CLASSIFICATION: PUBLIC SAFETY FACILITIES OPERATED
 BY PUBLIC AGENCIES. USE PERMITTED IN GC/NC.
  
 - INTERIOR MODIFICATIONS ONLY.