| Plan Review Stops For Permit 17030227 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-21 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-21 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-16 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-16 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2017-06-16 09:46:49 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | THE FOLLOWING ITEMS HAVE NOT BEEN CORRECTED FROM LAST | | | REVIEW. | | | | | | 1. SEE COMMENT #1 - DIMENSION FROM THE NOSING TO THE | | | TOP OF THE HANDRAIL IS SPECIFIED AS 30" (SEE PLAN PAGE | | | S-303). DIMENSION TO BE NOT LESS THAN 34" NOR MORE THAN | | | 38" PER FBC-R311.7.8.1. | | | R311.7.8.1 HEIGHT. | | | HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED | | | PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF | | | RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) | | | AND NOT MORE THAN 38 INCHES (965 MM). | | | | | | 2. SEE COMMENT #3 - NOTE #15 ON PLAN SHEET S-102 STATES | | | DRAFTSTOPPING SHALL NOT EXCEED 100 SF. FBC -R302.12 | | | STATES AREA NOT TO EXCEED 1000 SF. | | | R302.12 DRAFTSTOPPING. | | | IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE | | | BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A | | | FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED | | | SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED | | | 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING SHALL DIVIDE | | | THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. | | | WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE | | | ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL | | | BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE | | | FOLLOWING CIRCUMSTANCES: | | | | | | 3. SEE COMMENT #5 - PRODUCT APPROVALS TO BE REVIEWED | | | AND APPROVED BY DESIGNER OF RECORD PER FBC-R107.3.4. | | | SUBMITTED NOA 16-0629.16 FOR FRENCH DOORS IS NOT ON | | | APPROVED PRODUCT APPROVAL LIST (SEE PLAN SHEET S-000). | | | FBC 107.3.4.1 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | - THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 4. SEE COMMENT #6 - MANUFACTURERS INSTALLATION | | | INSTRUCTIONS SUBMITTED FOR OUTDOOR BBQ. SAFE OPERATING | | | PRACTICES PROHIBIT OPERATION UNDER OVERHEAD COMBUSTIBLE | | | CONSTRUCTION. SUMMER KITCHEN CEILING IS T&G. PLEASE | | | MCLARIFY. | | | | | | 5. SEE COMMENT #7 - NOA 16-0629.14 FOR ARCH TOP ENTRY | | | DOORS (FIXED WINDOW) SUBMITTED FOR REVIEW IS NOT ON | | | APPROVED PRODUCT APPROVAL LIST (SEE PLAN PAGE S-000). | | | FBC 107.3.4.1 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | - THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-30 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-25 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2017-05-30 13:57:05 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ON SHEET S-303, THE DIMENSION FROM THE NOSING TO THE | | | TOP OF THE HANDRAIL IS SPECIFIED AS 30" ON THE DETAIL. | | | FBC-R 311.7.8.1 REQUIRES THIS DIMENSION TO BE NOT LESS | | | THAN 34" NOR MORE THAN 38". | | | | | | 2) THE LANDSCAPE AND DRAINAGE PLAN THAT WAS SUBMITTED | | | DOES NOT SHOW COMPLIANCE WITH FBC-R 401.3 FOR SURFACE | | | WATER DRAINAGE. SUBMIT TWO SETS OF SURFACE WATER | | | DRAINAGE PLANS THAT SHOW COMPLIANCE WITH THE FOLLOWING: | | | R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE DIVERTED TO | | | A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF | | | COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE | | | GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES (152 | | | MM) WITHIN THE FIRST 10 FEET (3048 MM). | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE | | | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 | | | PERCENT AWAY FROM THE BUILDING. | | | | | | 3) NOTE #15 ON SHEET S-102, FOR DRAFTSTOPPING THE | | | CONCEALED SPACES OF THE FLOOR/CEILING ASSEMBLY | | | INCORRECTLY STATES THAT THE AREAS SHALL NOT EXCEED 100 | | | SF AND SECTION R 302.12 CODE STATES 1000 SF. PLEASE | | | CORRECT. | | | | | | 4) ON SHEET S-102, SPECIFY THE CONNECTORS THAT WILL BE | | | USED TO ATTACH THE FLOOR TRUSSES TO THE LEDGERS IN | | | ORDER TO RESIST LATERAL FORCES ON THE STRUCTURE. FBC | | | 107.2.1 | | | | | | 5) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD OF | | | THE STRUCTURE. FBC 107.3.4 | | | | | | 6) THE INFORMATION THAT WAS SUBMITTED FOR THE BUILT-IN | | | OUTDOOR BBQ DOES NOT HAVE THE LISTING INFORMATION OR | | | INSTALLATION REQUIREMENTS, SUCH AS, CLEARANCES TO | | | COMBUSTIBLES. SUBMIT ADDITION INFORMATION. FBC-R | | | 107.2.1 | | | | | | 7) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE ARCH | | | TOP ENTRY DOORS AS REQUIRED BY FBC 107.3.4. | | | | | | 8) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-21 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-21 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2017-04-21 17:02:42 | DUE TO COMPUTER SYSTEM FAILURE, THIS IS ACTUALLY THE | | | FIRST BUILDING PLAN REVIEW. | | | | | | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE MEAN ROOF HEIGHT (MRH) IS INCORRECTLY SPECIFIED | | | AS 15' ON SHEET S-000. THIS IS A TWO STORY STRUCTURE | | | AND THE MEAN ROOF HEIGHT APPEARS TO BE APPROXIMATELY | | | 25'. FBC-R301.2.1 | | | | | | 2) PROVIDE COMPONENT AND CLADDING PRESSURES FOR ROOF | | | ZONES 1, 2 & 3 AND WALL ZONES 4 & 5 ON THE PLANS. FBC | | | 107.3.5.3 - PROVIDE WIND DESIGN LOADS AND COMPONENT AND | | | CLADDING DESIGN PRESSURES PURSUANT TO FBC-R301.2. | | | | | | 3) SHOW COMPLIANCE WITH FBC-R 311.7 FOR STAIR | | | REQUIREMENTS ON THE PLANS. STAIR DETAIL #10 ON S-300 IS | | | FOR POURED CONCRETE STAIRS AND THE CODE REQUIREMENT | | | INFORMATION IS NOT PROVIDED. | | | | | | 4) SHOW COMPLIANCE WITH FBC-R 311.7.8 FOR HANDRAIL | | | REQUIREMENTS ON THE PLANS. | | | | | | 5) SHOW COMPLIANCE WITH FBC-R 312.1 FOR THE GUARDS | | | REQUIRED AT THE BALCONY AND THE STAIRS ON THE PLANS. | | | | | | 6) PROVIDE TWO SETS OF A SURFACE WATER DRAINAGE PLAN | | | THAT SHOWS COMPLIANCE WITH FBC-R 401.3. | | | | | | 7) THE SECOND FLOOR GAME ROOM HAS CLOSETS AND COULD BE | | | USED AS A SLEEPING ROOM NOW OR IN THE FUTURE. | | | THEREFORE, THE WINDOWS MUST COMPLY WITH FBC-R 310 FOR | | | EMERGENCY ESCAPE AND RESCUE. | | | | | | 8) SHOW COMPLIANCE WITH FBC-R 302.12 FOR DRAFTSTOPPING | | | OF THE CONCEALED SPACE OF THE FLOOR / CEILING ASSEMBLY | | | SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED | | | 1,000 SQUARE FEET. | | | | | | 9) SHOW THE TRUSS TO LEDGER CONNECTORS ON SHEET S-102 | | | AND THE ROOF TO WALL CONNECTORS ON SHEET S-103. THERE | | | ARE NO ID MARKS ON THE FLOOR AND ROOF FRAMING PLANS TO | | | SHOW THE LOCATIONS OF THE CONNECTORS THAT ARE LISTED IN | | | THE ANCHOR SCHEDULE ON SHEET S-400. | | | | | | 10) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE | | | ENERGY FORMS. TWO DIFFERENT ENERGY FORMS AND EQUIPMENT | | | SIZING CALCULATIONS WERE SUBMITTED. PLEASE REMOVE THE | | | OLD ONE AND SUBMIT AN ADDITIONAL COPY OF THE CORRECT | | | ONE. | | | | | | 11) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE ARCH TOP ENTRY | | | DOORS. | | | | | | 12) PRODUCT APPROVALS WERE SUBMITTED FOR STRUCTURAL | | | MULLIONS, HOWEVER, THE PLANS DO NOT APPEAR TO SHOW ANY | | | MULLIONS. PLEASE CLARIFY. FBC 107.2.1 | | | | | | 13) SUBMIT TWO SETS OF THE EVALUATION REPORTS FOR THE | | | ICYNENE SPRAY FOAM INSULATION. FBC-R 316 | | | | | | 14) SUBMIT TWO SETS OF THE MANUFACTURER?S | | | SPECIFICATIONS AND LISTING INFORMATION FOR THE BUILT-IN | | | OUTDOOR BBQ GRILL AND HOOD (IF ONE IS REQUIRED). | | | FBC-R107.2.1 | | | | | | 15) SPECIFY THE MATERIAL THAT WILL BE INSTALLED ON THE | | | CEILING OF THE SUMMER KITCHEN, LANAI AND COVERED ENTRY | | | AREAS. | | | | | | 16) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-19 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2017-04-20 15:22:48 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE MEAN ROOF HEIGHT (MRH) IS INCORRECTLY SPECIFIED | | | AS 15' ON SHEET S-000. THIS IS A TWO STORY STRUCTURE | | | AND THE MEAN ROOF HEIGHT APPEARS TO BE APPROXIMATELY | | | 25'. FBC-R301.2.1 | | | | | | 2) PROVIDE COMPONENT AND CLADDING PRESSURES FOR ROOF | | | ZONES 1, 2 & 3 AND WALL AREAS 4 & 5 ON THE PLANS. | | | FBC-R301.2.1 | | | | | | 3) SHOW COMPLIANCE WITH FBC-R 311.7 FOR STAIR | | | REQUIREMENTS ON THE PLANS. STAIR DETAIL #10 ON S-300 | | | ARE FOR POURED CONCRETE STAIRS AND ARE MISSING | | | INFORMATION. | | | | | | 4) SHOW COMPLIANCE WITH FBC-R 311.7.8 FOR HANDRAIL | | | REQUIREMENTS ON THE PLANS. | | | | | | 5) SHOW COMPLIANCE WITH FBC-R 312.1 FOR GUARDS | | | REQUIREMENTS AT THE BALCONY AND STAIR ON THE PLANS. | | | | | | 6) PROVIDE TWO SETS OF A SURFACE WATER DRAINAGE PLAN | | | THAT SHOWS COMPLIANCE WITH FBC-R401.3. | | | | | | 7) THE SECOND FLOOR GAME ROOM HAS CLOSETS AND COULD BE | | | USED AS A SLEEPING ROOM NOW OR IN THE FUTURE. THE | | | WINDOWS NEED TO COMPLY WITH FBC-R310 FOR EMERGENCY | | | ESCAPE ANE RESCUE. | | | | | | 8) **********************REVIEW NOT COMPLETE AT THIS | | | TIME******************** | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-03-23 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-03-23 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2017-03-23 11:37:59 | PROVISO! | | | | | | NEED TO SUBMIT PANEL SCHEDULES PRIOR TO THE FINAL | | | INSPECTION. | | | E3706.2 FBC RESIDENTIAL | | | | | | JLEAHY | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-21 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-07 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-30 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-11 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-21 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-03-06 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-16 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-14 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-04-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-19 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-19 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2017-04-19 07:50:04 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-04-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-04-18 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-04-18 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2017-04-18 13:58:46 | PASS PROVISO | | | 1) REFER TO SECTION M1301.3 PROVIDE MANUFACTURE | | | INSTALLATION INSTRUCTIONS | | | FOR RANGE HOOD AT FIRST INSPECTION. 2014 FBC(R) | | | 2) REFER TO SECTION M1602.4 BALANCED RETURN AIR. | | | REVISION REQUIRED | | | PROVIDE RETURN AIR FOR GAME ROOM 2014 FBC(R) | | | 3) PROVIDE A ENGINEER DETAIL ON THE CONDENSER TIE DOWN. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | FAX 561-805-6676 | | | OFFICE 561-805-6732 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-16 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-16 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-24 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-24 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2017-05-24 11:07:51 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. S-503 SANITARY RISER DIAGRAM. | | | A. THE WATER CLOSET AND BIDET IN THE MASTER BATHROOM | | | ARE NOT VENTED PROPERLY. PER FBC RES P3101.2.1 | | | B. THE SHOWER IN MASTER BATHROOM ARE NOT VENTED | | | PROPERLY. PER FBC RES P3101.2.1 | | | C. THE TWO BATHROOMS ON THE SECOND FLOOR RISER ARE NOT | | | LABELED CORRECTLY BATH#5 IS LABELED AS LAUNDRY BATH #3 | | | IS LABELED AS MASTERBATH PLEASE CLARIFY. PER WPB AMEND | | | TO FBC 107.2.1 | | | D. BATHROOM #4 IS MISSING ON THE SECOND FLOOR RISER | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | E. THE VENT ON THE WATER CLOSET IN THE BATHROOM #5 IS | | | NOT A REQUIRED VENTAND CAN NOT CONNECT TO-THE TOP OF | | | THE WATER CLOSET RISER PLEASE REMOVE. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 2. 2ND REQUEST A CLEAN OUT IS REQUIRED AT THE BASE OF | | | ALL SOIL STACKS. PER FBC RES P3005.2.6 | | | | | | 3. PLEASE INCLUDE HOT WATER SYSTEM ON WATER RISER | | | DIAGRAM. PER WPB AMEND TO FBC 107.2.1 | | | | | | I SUGGEST TO EXPEDITE AN APPROVAL FOR PLUMBING THAT A | | | MEETING BE SCHEDULED TO GO OVER THE COMMENTS ON THE | | | RISER DIAGRAM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-17 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-17 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2017-03-17 12:56:51 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. ON THE RISER THE WC IN MASTER BATHROOM IS NOT | | | VENTED. PER FBC PL P3101.2.1 | | | | | | 2. ON THE RISER THE LT IS NOT VENTED. PER FBC PL | | | P3101.2.1 | | | | | | 3. THE MASTER SH IS NOT SHOWN ON RISER PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. THE SOIL STACK FOR THE SECOND FLOOR IS NO SHOWN ON | | | THE GROUND FLOOR RISER PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 5. PLEASE PROVIDE A WATER RISER DIAGRAM. PER WPB AMEND | | | TO FBC 107.3.5.3(11) | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2017-04-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-19 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-19 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2017-04-19 16:55:15 | SAXONY 900 CONCRETE ROOF TILE - NOA NO. 16-0711.05 | | | BORAL TILE SEAL - NOA NO. 12-1219.01 | | | ICP ADHESIVES POLYSET AH-160 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-06-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-20 14:19:43 | ********************ZONING | | | PROVISO***************************************** | | | | | | DO NOT APPROVE FINAL WITHOUT CONFIRMING THAT LANDSCAPE | | | PERMIT HAS BEEN ISSUED AND INSPECTION OF LANDSCAPE | | | INTALLLATION HAS BEEN APPROVED. PLEASE CONTACT ME WITH | | | ANY QUESTIONS. | | | | | | THANKS, | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-05-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-05-23 15:56:16 | ******************ZONING | | | REVIEW************************* | | | | | | THE HEIGHT OF BUILDING AND OVERHANGS ARE FINE. THE | | | LANDSCAPE AND IRRIGATION PLAN SHOULD BE SUBMITTED AS A | | | SEPARATE PERMIT. PLEASE LET ME KNOW IF YOU HAVE ANY | | | QUESTIONS. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2017-03-14 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-03-13 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-03-14 10:40:28 | MAXIMUM HEIGHT IN THIS DISTRICT IS 30 FEET. | | | | | | SEC. 94-306. - HEIGHT EXCEPTIONS. | | | | | | (A) EXEMPTIONS TO HEIGHT LIMITS. HEATING, VENTILATION, | | | AND AIR CONDITIONING EQUIPMENT; CHURCH STEEPLES, BELL | | | TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, STAIR | | | ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR | | | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, | | | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES MAY | | | EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN PERCENT. | | | | | | OVERHANG FOR BALCONIES CANNOT ENCROACH MORE THAN 3 FEET | | | INTO SETBACKS. PLEASE PROVIDE BALCONY ENCROACHMENT. | | | | | | STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING | | | BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES, | | | AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER | | | THAN THREE FEET INTO ANY SETBACK. | | | | | | PLEASE SUBMIT LANDSCAPE AND IRRIGATION PLAN AS A | | | SEPARATE PERMIT. | | | | | | PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY HAVE. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] | | | |
|
|