Plan Review Details - Permit 17030199
Plan Review Stops For Permit 17030199
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-11 Cont ID  
Sent By tklarge Date 2017-03-11 Time 04:54 Rev Time 0.00
Received By tklarge Date 2017-03-09 Time 16:48 Sent To  
Notes
2017-03-09 16:48:46RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-08 Cont ID  
Sent By tklarge Date 2017-03-08 Time 13:25 Rev Time 0.00
Received By tklarge Date 2017-03-06 Time 13:07 Sent To  
Notes
2017-03-07 13:07:50PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-03-11 Cont ID  
Sent By tklarge Date 2017-03-11 Time 04:54 Rev Time 0.00
Received By tklarge Date 2017-03-11 Time 04:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-03-08 Cont ID  
Sent By tklarge Date 2017-03-08 Time 13:24 Rev Time 0.00
Received By tklarge Date 2017-03-08 Time 13:12 Sent To  
Notes
2017-03-08 13:24:491) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR THE
 POOL HEATER. THE HEATER SHALL BE LISTED AND LABELED PER
 THE 2014 FBC-FUEL GAS SEC.301.3 IF THE HEATER IS A GAS
 HEATER.
 .2) INDICATE THE BTU LOAD AND MODEL OF THE UNIT ON THE
 REQUESTED MANUFACTURER'S SPECIFICATION SHEETS.
 3) THE POOL HEATER SHALL MEET THE MINIMUM EFFICIENCY
 LISTED IN 2014 FBC-ENERGY TABLE C404.2.
 4) THE POOL HEATER SHALL COMPLY WITH 2014 FBC-ENERGY
 SEC. C404.7.2.(TIME SWITCHES).
 5) IF THE POOL HEATER IS GAS, A POOL CONTRACTOR CANNOT
 CONNECT THE GAS LINES TO THE HEATER. A SEPARATE PERMIT
 SHALL BE SUBMITTED AND ISSUED TO EITHER A PLUMBING
 CONTRACTOR OR A GAS CONTRACTOR. FL. STATUTE 489.105.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  