Plan Review Details - Permit 17030014
Plan Review Stops For Permit 17030014
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-05-11 Cont ID  
Sent By rmcdouga Date 2017-05-11 Time 13:38 Rev Time 0.00
Received By rmcdouga Date 2017-05-10 Time 16:37 Sent To  
Notes
2017-05-11 13:38:50APPROVED WITH EXCEPTIONS
  
 1) SUBMIT TWO SETS OF A SURVEY WITH THE CORRECT STREET
 NAME WHICH IS HORIZON DRIVE.
 2) SUBMIT TWO SETS OF THE MANUFACTURER'S SPECIFICATIONS
 AND INSTALLATION INSTRUCTIONS FOR THE BUILT-IN OUTDOOR
 BBQ GRILL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-04-18 Cont ID  
Sent By rmcdouga Date 2017-04-18 Time 17:04 Rev Time 0.00
Received By rmcdouga Date 2017-04-17 Time 18:09 Sent To  
Notes
2017-04-18 16:21:50PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SURVEY HAS THE STREET NAME FOR THIS PROJECT AS
 BAY POINTE LANE. THE PROPERTY APPRAISER AND CITY
 RECORDS INDICATE THAT THE STREET NAME IS HORIZON DRIVE.
 PLEASE REVISE THE SURVEY TO REFLECT THE STREET NAME AS
 HORIZON DRIVE. FBC 107.2.1
  
 2) UPDATE SHEETS A001 AND A801 TO REFERENCE THE 2014
 FBC - RESIDENTIAL AND THE 2011 EDITIONS OF ACI 318,
 315, 530, ASCE 5 AND TMS 402. FBC-R CHAPTER 46
  
 3) ON SHEET A001 UPDATE THE RESIDENTIAL POOL SAFETY ACT
 TO CHAPTER 45 OF THE 2014 FBC RESIDENTIAL AND DOOR &
 WINDOW REQUIREMENTS TO R4501.17
  
 4) ON SHEET A001 UPDATE THE TERMITE PROTECTION NOTE TO
 SECTION FBC-R 318 OF THE 2014 FBC.
  
 5) ON SHEET S5 UPDATE THE REFERENCED MASONRY STANDARDS
 FROM THE 2008 TO THE 2011 EDITIONS. FBC-R CHAPTER 46
  
 6) THE WIND EXPOSURE CATEGORY IS SPECIFIED AS "C" ON
 SHEET A001 AND AS "D" ON SHEET S5. PLEASE REVISE PLANS
 TO BE CONSISTENT WITH REGARD TO THE EXPOSURE CATEGORY.
 FBC-R301.2.1.4
  
 7) PLEASE CLARIFY THE COMPONENT AND CLADDING DESIGN
 PRESSURES ON SHEET S5. THEY ARE +35.14, -38.54 PSF FOR
 WALL ZONE 4 AND +35.14, -43.83 PSF FOR WALL ZONE 5. THE
 EFFECTIVE WIND AREA IS NOT SPECIFIED. ASSUMING WORST
 CASE EFFECTIVE WIND AREA OF 10 SQFT., THESE PRESSURES
 ARE LOW FOR A STRUCTURE WITH A 20' MEAN ROOF HEIGHT
 LOCATED IN EXPOSURE D AND A 170 MPH VULT WIND SPEED.
 FBC-R301.2.1
  
 8) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD.
  
 9) THE PRODUCT APPROVAL INSTALLATION DRAWINGS THAT WERE
 SUBMITTED ARE TOO SMALL TO BE CLEARLY LEGIBLE. IT
 APPEARS THAT THEY SHOULD HAVE BEEN PRINTED IN LANDSCAPE
 ORIENTATION RATHER THAN PORTRAIT. PLEASE SUBMIT LARGER
 DRAWINGS. FBC 107.2.1
  
 10) SUBMIT TWO SETS OF MANUFACTURER'S SPECIFICATIONS
 WITH THE OUTDOOR BBQ'S LISTING INFORMATION AND
 INSTALLATION INSTRUCTIONS. IF A HOOD IS REQUIRED SUBMIT
 IT'S SPECIFICATIONS. FBC 107.2.1
  
 11) SPECIFY ON THE PLANS THE MATERIAL THAT WILL BE
 INSTALLED ON THE CEILING OF THE OUTDOOR LIVING AREA.
 FBC 107.2.1
  
 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-05-22 Cont ID  
Sent By jleahy Date 2017-05-22 Time 11:04 Rev Time 0.00
Received By jleahy Date 2017-05-22 Time 11:04 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-17 Cont ID  
Sent By jleahy Date 2017-03-17 Time 08:11 Rev Time 0.00
Received By jleahy Date 2017-03-16 Time 12:37 Sent To  
Notes
2017-03-17 08:12:48NEEDS REVISED PANEL SCHEDULES BEFORE FINAL INSPECTION.

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2017-05-08 Cont ID  
Sent By gjohnson Date 2017-05-08 Time 08:28 Rev Time 0.00
Received By gjohnson Date 2017-05-08 Time 08:28 Sent To  
Notes
2017-05-08 08:29:08GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-03-15 Cont ID  
Sent By gjohnson Date 2017-03-15 Time 15:21 Rev Time 0.00
Received By gjohnson Date 2017-03-15 Time 15:21 Sent To  
Notes
2017-03-15 15:22:02GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-05-23 Cont ID  
Sent By rmcdouga Date 2017-05-23 Time 07:15 Rev Time 0.00
Received By rmcdouga Date 2017-05-18 Time 14:47 Sent To  
Notes
2017-05-19 14:47:59RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-12 Cont ID  
Sent By njwira Date 2017-05-12 Time 13:58 Rev Time 0.00
Received By njwira Date 2017-04-27 Time 12:40 Sent To  
Notes
2017-04-28 12:41:01R14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-18 Cont ID  
Sent By rmcdouga Date 2017-04-18 Time 17:04 Rev Time 0.00
Received By rmcdouga Date 2017-03-01 Time 13:09 Sent To  
Notes
2017-03-02 13:09:32R14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-05-25 Cont ID  
Sent By rmcdouga Date 2017-05-25 Time 16:18 Rev Time 0.00
Received By rmcdouga Date 2017-05-25 Time 16:18 Sent To  
Notes
2017-05-25 16:19:52MU-2017-14599, PAID $9,904.34.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-04-17 Cont ID  
Sent By rmcdouga Date 2017-04-17 Time 17:57 Rev Time 0.00
Received By rmcdouga Date 2017-04-17 Time 17:57 Sent To  
Notes
2017-04-17 17:58:49BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-05-23 Cont ID  
Sent By rmcdouga Date 2017-05-23 Time 07:15 Rev Time 0.00
Received By rmcdouga Date 2017-05-22 Time 16:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-05-11 Cont ID  
Sent By rmcdouga Date 2017-05-11 Time 15:59 Rev Time 0.00
Received By rmcdouga Date 2017-05-11 Time 06:46 Sent To  
Notes
2017-05-11 15:59:01PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SOME OF THE INFORMATION ON THE PLANS THAT WERE
 SUBMITTED IS ILLEGIBLE. FBC 107.2.1
  
 2) THE RETURN AIR FOR THE LIBRARY IS CONNECTED TO THE
 AIR HANDLER THAT DOES NOT SUPPLY AIR TO THE ROOM. THE
 SUPPLY AND RETURN AIR NEED TO BE FROM THE SAME SYSTEM.
 FBCR-M1601
  
 3) THERE ARE SOME DISCREPANCIES BETWEEN THE EQUIPMENT
 SIZING CALCULATIONS, THE PLANS AND ENERGY FORM
 R405-2014. THE FORM R405-2014 HAS 17,000 BTU OF HEAT
 FOR THE #2 SYSTEM AND THE ENERGY CALCULATIONS HAS
 25,500 BTU. THE PLANS SPECIFY 10 KW FOR THE HEAT ON
 SYSTEM #2 AND THE ENERGY CALCULATIONS SPECIFY 7.5 KW.
 THE MODEL NUMBERS FOR THE EQUIPMENT ON THE PLANS DO NOT
 MATCH THE ONES LISTED ON THE ENERGY CALCULATIONS. FBC
 ENERGY CONSERVATION R-403.6
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-18 Cont ID  
Sent By rmcdouga Date 2017-04-18 Time 06:55 Rev Time 0.00
Received By rmcdouga Date 2017-04-18 Time 06:42 Sent To  
Notes
2017-04-18 06:54:48PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC - 107.3.5.3 PROVIDE TWO SETS OF A MECHANICAL
 PLAN TO SHOW EQUIPMENT, EQUIPMENT LOCATION AND DUCT
 SYSTEMS PER FBC-R M16 & BATH EXHAUST PER FBC-R M15.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-05-08 Cont ID  
Sent By gjohnson Date 2017-05-08 Time 08:28 Rev Time 0.00
Received By gjohnson Date 2017-05-05 Time 13:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-03-15 Cont ID  
Sent By gjohnson Date 2017-03-15 Time 15:15 Rev Time 0.00
Received By gjohnson Date 2017-03-15 Time 14:53 Sent To  
Notes
2017-03-15 15:20:141ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. MASTER BATH TUB IS MISSING ON PLUMBING RISER. PER
 WPB AMEND TO FBC 107.2.1
  
 2. BAR SINK IN GREAT ROOM IS MISSING ON THE RISER. PER
 WPB AMEND TO FBC 107.2.1
  
 3. THE WASHING MACHINE CAN NOT CONNECT TO THE BATHROOM
 GROUP IT SHALL CONNECT TO BUILDING DRAIN DOWN STREAM OF
 THE BATHROOM GROUP. PER FBC RES P3108.1
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-05-12 Cont ID  
Sent By njwira Date 2017-05-12 Time 13:56 Rev Time 0.00
Received By njwira Date 2017-05-12 Time 09:18 Sent To I
Notes
2017-05-12 13:57:555/12/17- PASSED
  
 LANDSCAPE PERMIT REQUIRED PRIOR TO CO
 DRIVEWAY PERMIT IS SEPORATE
 POOL PERMIT IS SEPORATE
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-03-10 Cont ID  
Sent By njwira Date 2017-03-10 Time 17:26 Rev Time 0.00
Received By njwira Date 2017-03-10 Time 17:26 Sent To  
Notes
2017-03-10 17:27:593/10/17- FAILED
 IBIS RESIDENTIAL PLANNED DEVELOPMENT
 FAILED
 LANDSCAPE PLAN REQUIRED
 PLEASE INDICATE SETBACKS ON A SITE PLAN OR SURVEY
 PLEASE INCLUDE ELEVATION DRAWINGS
  
 PASSED
  
 ONE KITCHEN ONE UNIT
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved