| Plan Review Stops For Permit 17030013 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-27 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-27 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2017-03-27 12:30:30 | SEE SHEET A2-1, PERMIT #00080861 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-02 |
Time |
08:29 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2017-02-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-03-02 08:29:44 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17030013 | | | ADD: 700 S. ROSEMARY AVE. SUITE : 117 | | | CONT: TBD | | | TEL: 561-856-6655 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. MARCH 02/ 2017 | | | ACTION: DENIED | | | | | | 1) SHEET A2.0 TENANT REQUESTED CHANGE THE OFFICE AREA | | | WAS CHANGED TO A DRESSING ROOM. OCCUPANTS CAN NOT PASS | | | THROUGH A STORAGE ROOM. 2014 FBC-B 1014.1(4) | | | EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, | | | CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. | | | | | | 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | 2017-03-02 08:05:55 | REVIEWED UNDER PERMIT APP. 16040524. (REVOKED, SEE NEW | | | PERMIT APP. 17030013) SAME SET OF PLANS THAT WERE | | | STAMPED. JW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-03-14 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-03-14 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2017-03-14 11:06:27 | PROVISO! | | | INFORMATION REQUIRED PRIOR TO FINAL INSPECTION. | | | 1) NEED A LIGHTING CONTROL DIAGRAM. | | | 2) SMALL SPACES REQUIRE OCCUPANY SENSORS. | | | | | | | | | JAKE LEAHY | | | 561-805-6713 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-23 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-02-24 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-02-24 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2017-02-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-03-02 08:05:22 | REVIEWED UNDER PERMIT APP. 16040524. (REVOKED, SEE NEW | | | PERMIT APP. 17030013) SAME SET OF PLANS THAT WERE | | | STAMPED. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-03-28 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2017-03-21 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-03-14 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2017-02-21 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2017-03-02 08:02:32 | NEW PERMIT TRACKING # 17030013 WITH FEES. PERMIT | | | 16040524 REVOKED. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-02 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-02 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-29 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-29 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-28 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-28 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2017-03-28 07:37:07 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030013 | | | 3/28/17 | | | | | | 1) THE DRESSING ROOM HAS BEEN REMOVED FROM THE | | | ARCHITECTURAL PLANS, HOWEVER THE ELECTRICAL PLANS ARE | | | STILL SHOWING IT- SEE SHEETS E1.1 & E2.1. EITHER REVISE | | | THE SHEETS OR PROVIDE THE EXHAUST SYSTEM AS PREVIOUSLY | | | NOTED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-14 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-14 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2017-03-14 14:01:12 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17030013 | | | 3/14/17 | | | | | | 1) THE NEW DRESSING ROOM REQUIRES AN EXHAUST SYSTEM | | | WITH AN AIRFLOW RATE OF .25 CFM'S PER SQ FT.- SEE TABLE | | | 403.3. REVISE THE PLANS ACCORDINGLY | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-28 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-28 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-06 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-06 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2017-03-06 10:11:14 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SINK IN BRAKE-ROOM SHALL COMPLY WITH FBC ACC 606.3 | | | HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | 606.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR | | | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-03-28 |
Time |
17:59 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-03-28 |
Time |
17:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-03-14 |
Time |
16:29 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-03-14 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2017-03-14 16:45:17 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) THE NEW PLANS SHOW THE AREA WHERE THE EXISTING | | | NORTHERN DOOR IS AS BEING ENCLOSED WITH A SOLID WALL. | | | THE PREVIOUS PLAN SHOWED THIS AS STOREFRONT GLAZING. | | | STAFF DOES NOT SUPPORT THIS CHANGE AND FINDS THAT IT | | | DOES NOT COMPLY WITH THE REQUIREMENT OF THE MASTER | | | DESIGN GUIDELINES THAT THE REQUIRE BUILDING FACADES TO | | | BE WINDOWED. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|