Plan Review Details - Permit 17021235
Plan Review Stops For Permit 17021235
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-05-23 Cont ID  
Sent By jwitmer Date 2017-05-23 Time 16:59 Rev Time 0.00
Received By jwitmer Date 2017-05-23 Time 16:17 Sent To  
Notes
2017-05-23 16:59:45BUILDING PROVISO:
 2014 FBC-BUILDING CODE/ BUILDING WELDED OR BOLTED
 CONNECTIONS
 THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2014 FBC-B 2204.1 WELDING
 2014 FBC-B 2204.2 BOLTING.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By jwitmer Date 2017-03-22 Time 15:19 Rev Time 0.00
Received By jwitmer Date 2017-03-22 Time 09:55 Sent To  
Notes
2017-03-22 15:19:43BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17021235
 ADD: 931 VILLAGE BLVD. EXT. RENOVATION/ BUILD OUT
 EXTERIOR DECK
 CONT: TBD/ TO BE DETERMINED
 TEL: EXPEDITOR: 289-0276
 E-MAIL: ?????????
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MARCH 22/ 2017
 ACTION: DENIED
  
 1) SHEET A-LS1 THE SQUARE FOOTAGE FOR THE NEW OUTDOOR
 SEATING AREA 2073 SQ. FT. + 2092 SQ. FT. = 4165 SQ. FT.
 IN AREA. THIS IS A DISCREPANCY OF THE APPROVED SQ. FT.
 OF 3969 SQ. FT. UNDER THE ZONING RESOLUTION SHEET LP-2.
 ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.3.
  
 2) SHEET S-3 PROVIDES THE WIND DESIGN CRITERIA. UNDER
 THE HEADING FOR WIND EXPOSURE THE TERM N4 IS USED.
 PLEASE REFER TO THE 2014 FBC-B 1609.4.2 SURFACE
 ROUGHNESS CATEGORY C WOULD APPLY. THIS SURFACE
 ROUGHNESS SHALL ALSO APPLY TO ANY BUILDING LOCATED
 WITHIN SURFACE ROUGHNESS B TYPE TERRAIN WHERE THE
 BUILDING IS WITHIN 100 FEET (30 M) HORIZONTALLY IN ANY
 DIRECTION OF OPEN AREAS OF SURFACE ROUGHNESS C OR
 D-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET IN THE
 UPWIND DIRECTION AND A WIDTH GREATER THAN 150 FEET.
 PLEASE UPDATE THE PLANS.
  
 3) SHEET S-3 PROVIDES THE WIND DESIGN CRITERIA. THE
 WIND DESIGN CRITERIA LIST A INTERNAL PRESSURES
 COEFFICIENT THAT IS FOR AN ENCLOSED BUILDING. IT WOULD
 APPEAR THAT THE DESIGNER OF RECORD WOULD NEED TO SUPPLY
 (2) DESIGN CRITERIA. THE FIRST FOR THE WORK TO BE
 COMPLETED FOR THE ENCLOSED BUILDING WHERE IS WORK BEING
 COMPLETED IN MODIFYING THE ROOF STRUCTURE AND THE
 ASSOCIATED PRESSURES 2014 FBC-B 1609.1.1. THE SECOND
 SET OF DESIGN CRITERIA FOR WHAT APPEARS TO BE AN OPEN
 CANOPY STRUCTURE. THESE DESIGN CRITERIA WOULD BE
 REQUIRED FOR THE DELEGATE ENGINEER WHO WILL ULTIMATELY
 PROVIDE DRAWINGS FOR THE LOUVERED ROOF CANOPY SYSTEM.
  
 4) THE DESIGNER OF RECORD HAS NOT PROVIDED ENOUGH
 INFORMATION ON THE ARCADIA LOUVERED ROOF SYSTEM BY
 ABSOLUTE ALUMINUM TO DO A CODE REVIEW .
 4A) DEFINITION OF ROOF. ROOF ASSEMBLY (FOR APPLICATION
 TO CHAPTER 15 ONLY). A SYSTEM DESIGNED TO PROVIDE
 WEATHER PROTECTION AND RESISTANCE TO DESIGN LOADS. THE
 SYSTEM CONSISTS OF A ROOF COVERING AND ROOF DECK OR A
 SINGLE COMPONENT SERVING AS BOTH THE ROOF COVERING AND
 THE ROOF DECK. A ROOF ASSEMBLY INCLUDES THE ROOF DECK,
 VAPOR RETARDER, SUBSTRATE OR THERMAL BARRIER,
 INSULATION, VAPOR RETARDER AND ROOF COVERING.
  
 4B) SINCE THE CANOPY ROOF SYSTEM IS A MECHANIZED LOUVER
 SYSTEM THAT ALSO HAS AN INTEGRAL GUTTER SYSTEM, AND A
 SINGLE COMPONENT SERVING AS DECK/ ROOF COVERING THIS
 SYSTEM WILL NEED TO MEET THE FOLLOWING REQUIREMENTS:
 4B)(1) 2014 FBC-B 1506.3 MATERIAL SPECIFICATIONS AND
 PHYSICAL CHARACTERISTICS. ROOF-COVERING MATERIALS SHALL
 CONFORM TO THE APPLICABLE STANDARDS LISTED IN THIS
 CHAPTER. IN THE ABSENCE OF APPLICABLE STANDARDS OR
 WHERE MATERIALS ARE OF QUESTIONABLE SUITABILITY,
 TESTING BY AN APPROVED AGENCY SHALL BE REQUIRED BY THE
 BUILDING CODE OFFICIAL TO DETERMINE THE CHARACTER,
 QUALITY AND LIMITATIONS OF APPLICATION OF THE
 MATERIALS.
  
 4B)(2) 2014 1506.4 PRODUCT IDENTIFICATION.
 ROOF-COVERING MATERIALS SHALL BE DELIVERED IN PACKAGES
 BEARING THE MANUFACTURER?S IDENTIFYING MARKS AND
 APPROVED TESTING AGENCY LABELS REQUIRED IN ACCORDANCE
 WITH SECTION 1505.
  
 4B)(3) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31(D) ROOFING PRODUCTS AND ASSEMBLIES.
  
 5) SHEET A-LS1 THE CODE ANALYSIS INDICATES THIS
 BUILDING IS A BUILDING TYPE IIB. THE SHEETS A-3.02,
 A-3.03, S-3 AND S-4 ALL SHOW WOOD TRUSSES, THE
 ARCHITECTURAL PLANS INDICATE SHEATHING BUT NOT
 SPECIFIED. THE STRUCTURAL SHEET S-4 INDICATES ? INCH
 WOOD SHEATHING. PLEASE SEE THE REQUIREMENTS FOR
 COMBUSTIBLE MATERIALS IN TYPE II CONSTRUCTION 603.1.1
 FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN:
 1.3. ROOF CONSTRUCTION, INCLUDING GIRDERS, TRUSSES,
 FRAMING AND DECKING.
  
 6) SHEET S2 DOES SHOW THE INSTALLATION OF NEW W10X20
 STEEL BEAMS. SHEET S-3SHOWS A TYPICAL BOX BEAM DETAIL,
 SHEET S-4 SHOWS AN SIMPSON H8 TIE DOWN. THE PLANS DO
 NOT PROVIDE WHAT MATERIAL IS ON THE EXTERIOR SIDE OF
 THE W10X20 STEEL BEAM, THICKNESS AND HOW IS THIS
 MATERIAL TO BE ATTACHED TO THE STEEL BEAM? SHEET S4
 SHOWS THE SIMPSON H8 TIE DOWN BUT DOES NOT PROVIDE THE
 LOADS TO BE RESISTED FOR UPLIFT NOR THE LATERAL LOADS.
 THE SIMPSON H8 IS DESIGNED TO FASTEN WITH (5) 1 ? INCH
 # 10D NAILS TO BOTH THE TRUSS AND TOP PLATE. HOW WILL
 THE 1 ? INCH NAILING BIT BE ACCOMPLISHED WHEN THE SIDE
 WALL MATERIAL SURROUNDING THE STEEL BEAM IS UNKNOWN AND
 THE THICKNESS OF THE MATERIAL TO BE INSTALLED?
  
 7) THE CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2014 FBC-B 2204.1 WELDING
 2014 FBC-B 2204.2 BOLTING.
  
 8) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, INCLUDING
 ROOF TOP INSULATION
  
 9) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 10) BUILDING PROVISO: THE EXISTING ROOF STRUCTURE SHALL
 BE SHORED PRIOR TO THE REMOVAL OF THE EXISTING BEAM.
 SHORING SYSTEMS SHALL BE DESIGNED BY THE CONTRACTORS
 DELEGATE ENGINEER. THE DELEGATED ENGINEER SHALL FORWARD
 THE DELEGATED ENGINEERING DOCUMENTS TO THE ENGINEER OF
 RECORD FOR REVIEW PRIOR TO SUBMISSION TO THE BUILDING
 DEPARTMENT. FL 61G-15-30.006 (3).
  
 11) THE LIFE SAFETY SHEET DOES NOT SHOW COMPLIANCE WITH
 THE 2014 FBC-ACCESSIBILITY CODE;
  
 11A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 11B) 226.2 DISPERSION. DINING SURFACES AND WORK
 SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 11C) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3.
 ADVISORY 902.1 GENERAL. DINING SURFACES INCLUDE, BUT
 ARE NOT LIMITED TO, BARS, TABLES, LUNCH COUNTERS, AND
 BOOTHS. EXAMPLES OF WORK SURFACES INCLUDE WRITING
 SURFACES, STUDY CARRELS, STUDENT LABORATORY STATIONS,
 BABY CHANGING AND OTHER TABLES OR FIXTURES FOR PERSONAL
 GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ABA
 SCOPING PROVISIONS, EMPLOYEE WORK STATIONS.
  
 11C)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR
 FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 11C)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND
 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 12) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY.
 THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-06-05 Cont ID  
Sent By jpearson Date 2017-06-05 Time 12:30 Rev Time 0.00
Received By jpearson Date 2017-06-05 Time 12:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-09 Cont ID  
Sent By rlecky Date 2017-03-09 Time 14:50 Rev Time 0.00
Received By rlecky Date 2017-03-09 Time 13:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-05-12 Cont ID  
Sent By pleduc Date 2017-05-12 Time   Rev Time 0.00
Received By pleduc Date 2017-05-12 Time 12:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-03-07 Cont ID  
Sent By pleduc Date 2017-03-07 Time   Rev Time 0.00
Received By pleduc Date 2017-03-07 Time 17:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-05 Cont ID  
Sent By jpearson Date 2017-06-05 Time 12:31 Rev Time 0.00
Received By jpearson Date 2017-05-10 Time 11:48 Sent To  
Notes
2017-05-11 11:48:16C08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-22 Cont ID  
Sent By jwitmer Date 2017-03-22 Time 15:33 Rev Time 0.00
Received By jwitmer Date 2017-02-28 Time 16:00 Sent To  
Notes
2017-03-01 16:00:50C08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2018-01-08 Cont ID  
Sent By jwitmer Date 2018-01-08 Time 14:04 Rev Time 0.00
Received By jwitmer Date 2018-01-08 Time 14:04 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-05-23 Cont ID  
Sent By jwitmer Date 2017-05-23 Time 16:17 Rev Time 0.00
Received By jwitmer Date 2017-05-23 Time 16:17 Sent To  
Notes
2017-05-23 16:17:25BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By jwitmer Date 2017-03-22 Time 15:20 Rev Time 0.00
Received By jwitmer Date 2017-03-22 Time 10:01 Sent To  
Notes
2017-03-22 15:20:20BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2017-05-18 Cont ID  
Sent By eschneid Date 2017-05-18 Time 11:03 Rev Time 0.25
Received By eschneid Date 2017-05-17 Time 17:13 Sent To  
Notes
2017-05-18 11:04:04SEPARATE PERMITS ARE REQUIRED FOR:
  
 A. LANDSCAPE
 B. SIGNAGE - PLEASE NOTE THAT THIS WILL BE REVIEWED ON
 AN INDIVIDUAL BASIS FOR EACH BUSINESS BASED ON THEIR
 FACADE AREA. THE SQUARE FOOTAGE SHOWN ON THE PARAPET
 PLANS DOES NOT ESTABLISH THE PERMITTED AMOUNT OF
 SIGNAGE FOR EACH BUSINESS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-03-16 Cont ID  
Sent By eschneid Date 2017-03-16 Time 10:14 Rev Time 0.75
Received By eschneid Date 2017-03-15 Time 10:42 Sent To  
Notes
2017-03-16 10:14:15FAILED
  
 PROVIDE WRITTEN RESPONSE.
  
 1) THE AMOUNT OF OUTDOOR SEATING APPROVED BY RESOLUTION
 NO. 358-16 IS 3,969 SQUARE FEET. THE PERMIT SHOWS 4,165
 SQUARE FEET OF OUTDOOR SEATING. EITHER REDUCE THE
 AMOUNT OF OUTDOOR SEATING BY 196 SQUARE FEET, OR SHOW
 ON THE DEMOLITION PLAN THE REMOVAL OF 196 SQUARE FEET
 OF THE EXISTING BUILDING.
  
 2) THE PLANS MUST SHOW THE DIMENSION BETWEEN THE NEW
 CURBLINE AT THE PARKING LOT SIDE OF THE OUTDOOR SEATING
 AND THE EXISTING TERMINAL LANDSCAPE ISLANDS IN THE
 PARKING LOT. THIS DIMENSION MUST BE A MINIMUM OF 20
 FEET.
  
 3) SEPARATE PERMITS ARE REQUIRED FOR:
  
 A. LANDSCAPE
 B. SIGNAGE - PLEASE NOTE THAT THIS WILL BE REVIEWED ON
 AN INDIVIDUAL BASIS FOR EACH BUSINESS BASED ON THEIR
 FACADE AREA. THE SQUARE FOOTAGE SHOWN ON THE PARAPET
 PLANS DOES NOT ESTABLISH THE PERMITTED AMOUNT OF
 SIGNAGE FOR EACH BUSINESS.
 C. THE OPERABLE ALUMINUM LOUVER SYSTEM
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]