| 2017-04-13 10:28:06 | ** FAILED ** |
| | |
| | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE |
| | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE |
| | APPLICABLE: |
| | |
| | 1.) 3/23/17 REPEAT COMMENT: SURVEY MUST BE SIGNED AND |
| | SEALED. |
| | |
| | 2.) 3/23/17 REPEAT COMMENT: THE MODIFIED CURB CUTS ON |
| | PERSHING WAY AND THE ALLEY REQUIRES A ROW PERMIT FROM |
| | THE ENGINEERING SERVICES DEPARTMENT. PLEASE PROVIDE. |
| | |
| | 3.) 3/23/17 REPEAT COMMENT: HOW FAR DOES THE STRUCTURAL |
| | CANOPY PROJECT INTO THE ROW ALONG SOUTH DIXIE HIGHWAY |
| | AND PERSHING WAY? ROW PERMIT FROM FDOT IS REQUIRED FOR |
| | THE STRUCTURAL OVERHANG OVER SOUTH DIXIE HIGHWAY. ALSO, |
| | PLEASE DIMENSION THE ENCROACHMENT. |
| | |
| | 4.) 3/23/17 REPEAT COMMENT: PROVIDE ALL SETBACK |
| | DIMENSIONS FROM THE PROPERTY LINE FOR EACH OF THE |
| | DUMPSTERS PROPOSED IN THE SITE PLAN. |
| | |
| | 5.) THE BICYCLE RACKS SHALL BE MOUNTED ON A CONCRETE |
| | PAD. PLEASE ILLUSTRATE IN THE SITE PLAN AND PROVIDE |
| | DIMENSIONAL INFORMATION IN THE BICYCLE PARKING DETAIL |
| | ON SHEET A-8.0. ALSO, THE LOCATION OF THE BICYCLE RACK |
| | SEEMS TO CONFLICT WITH THE REQUIREMENTS OF PROVIDING |
| | LANDSCAPE ISLANDS. |
| | |
| | 6.) PROVIDE BICYCLE PARKING CALCULATIONS IN THE "ZONING |
| | DATA" TABULAR IN SHEET A-1.0. |
| | |
| | 7.) THE MINIMUM SETBACK REQUIREMENT FOR LIGHT FIXTURES |
| | IS 5 FT. FROM THE PROPERTY LINE. PLEASE DEMONSTRATE |
| | COMPLIANCE BY PROVIDING DIMENSIONS IN THE SITE PLAN. |
| | |
| | 8.) PLEASE DIMENSION THE LOADING ZONE. THE LOADING ZONE |
| | SHALL BE A MINIMUM OF 10 FT. WIDE BY 25 FT. LONG. [ZLDR |
| | S.94-485] |
| | |
| | 9.) 3/23/17 REPEAT COMMENT: THE PHOTOMETRIC PLAN MUST |
| | DEMONSTRATE THAT ALL LIGHT FIXTURES WILL NOT CAUSE |
| | ILLUMINATION IN EXCESS OF 0.5 FOOT CANDLES WHEN |
| | MEASURED IN A RESIDENTIAL ZONING DISTRICT. PLEASE SHOW |
| | LIGHT OVERFLOW BEYOND THE NORTH AND EAST PROPERTY LINE |
| | WHERE THERE ARE RESIDENTIAL UNITS IN THE PHOTOMETRIC |
| | PLAN. ALL LIGHT FIXTURES MUST BE ARRANGED TO REFLECT |
| | LIGHT AWAY FROM ALL RESIDENTIAL ZONING DISTRICTS. [ZLDR |
| | S.94-309 AND S.94-310(D)] |
| | |
| | 10.) ALL ROOFTOP MECHANICAL EQUIPMENT SHALL NOT BE |
| | VISIBLE FROM VIEW. THIS SHALL BE NOTATED IN THE PLANS. |
| | |
| | NOTES: |
| | |
| | * ANY CHANGES TO THE PROJECT SHALL BE REFLECTED IN ALL |
| | PLANS FOR CONSISTENCY. |
| | |
| | * REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |