Plan Review Details - Permit 17021129
Plan Review Stops For Permit 17021129
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-03-07 Cont ID  
Sent By jgomez Date 2017-03-07 Time 11:58 Rev Time 0.00
Received By jgomez Date 2017-03-07 Time 11:28 Sent To  
Notes
2017-03-07 11:45:04BUILDING REVIEW APPROVED WITH PROVISO:
 1- GARAGE DOOR STRUCTURAL BUCK: PROVIDE COMPLETE DETAIL
 AND SPECIFICATIONS FOR THE ATTACHMENT OF THE STRUCTURAL
 BUCK TO THE SUPPORTING STRUCTURE. SPECIFY BUCK SIZE,
 FASTENER TYPE, SIZE AND SPACING. DETAIL #11 ON SHEET
 12ABCD DOESN'T PROVIDE THIS INFORMATION.
 2- ARROW ORIENTATION SHOWN ON SHEET 2 OF 2 OF SURVEY
 SUBMITED IS INCORRECT. REVISE AS REQUIRED.
 3- TRUSS PACKAGE SUBMITTED: THERE IS NO NEED TO SUBMIT
 TRUSS PACKAGE FOR SINGLE FAMILY RESIDENCES (R3). THE
 TRUSS PACKAGE NEEDS TO BE REVIEWED AND APPROVED IN
 WRITING BY THE ARCHITECT OF RECORD. THEN, DELIVER THE
 TRUSS PACKAGE TO THE BUILDING INSPECTOR AT TIME OF
 FRAMING INSPECTION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-10 Cont ID  
Sent By vperez Date 2017-03-10 Time 08:14 Rev Time 0.00
Received By vperez Date 2017-03-10 Time 08:14 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2017-03-15 Cont ID  
Sent By gjohnson Date 2017-03-15 Time 12:49 Rev Time 0.00
Received By gjohnson Date 2017-03-15 Time 12:49 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-03-10 Cont ID  
Sent By gjohnson Date 2017-03-10 Time 09:27 Rev Time 0.00
Received By gjohnson Date 2017-03-10 Time 09:27 Sent To  
Notes
2017-03-10 10:20:361ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 1. PLEASE PROVIDE COMBUSTION AIR CALCULATIONS FOR WATER
 HEATER AND DRYER. PER THE FBC-2014 FUEL GAS CODE SEC.
 304
  
 2.THE FIRST SECTION OF CSST UPSTREAM OF THE DRYER
 SHOULD BE EHD OF 37 OR 11/4 CSST . PER FBC FUEL GAS
 TABLE 402.4(15)
  
 3. THE SECOND SECTION OF CSST BETWEEN DRYER AND COOK
 TOP SHOULD BE EHD OF 31 OR 1" CSST . PER FBC FUEL GAS
 TABLE 402.4(15)
  
 4.THE NOTE ON THE PLAN UNDER NAT. GAS @ 12-14" WC
 STATES TOTAL BTU 568M THE RISER AND APPLIANCE SCHEDULE
 SHOWS TOTAL BTU LOAD AT 168M PLEASE CLARIFY. PER WPB
 AMEND TO FBC 107.2.1
  
 5. PLEASE PROVIDE SIZING TABLES USED TO SIZE SYSTEM.
 PER WPB AMEND TO FBC 107.2.1
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-10 Cont ID  
Sent By gjohnson Date 2017-03-10 Time 10:20 Rev Time 0.00
Received By gjohnson Date 2017-02-27 Time 13:07 Sent To  
Notes
2017-02-28 13:07:48R24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-03-07 Cont ID  
Sent By jgomez Date 2017-03-07 Time 16:04 Rev Time 0.00
Received By jgomez Date 2017-03-07 Time 16:04 Sent To  
Notes
2017-03-07 16:05:00$10,003.08 PAID. MU-2017-005174.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-03-07 Cont ID  
Sent By jgomez Date 2017-03-07 Time 12:20 Rev Time 0.00
Received By jgomez Date 2017-03-07 Time 12:08 Sent To  
Notes
2017-03-07 12:21:21PROVIDE COPY OF PAID IMPACT FEES RECEIPT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-03-07 Cont ID  
Sent By jgomez Date 2017-03-07 Time 11:58 Rev Time 0.00
Received By jgomez Date 2017-03-07 Time 11:58 Sent To  
Notes
2017-03-07 12:00:54MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 1- DEN ROOM NEEDS TO COMPLY WITH THE BALANCED RETURN
 AIR SEC. M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014).

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-10 Cont ID  
Sent By gjohnson Date 2017-03-10 Time 09:15 Rev Time 0.00
Received By gjohnson Date 2017-03-10 Time 09:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-03-07 Cont ID  
Sent By jgomez Date 2017-03-07 Time 12:38 Rev Time 0.00
Received By jgomez Date 2017-03-07 Time 12:08 Sent To  
Notes
2017-03-07 12:38:29A) ROOF TILE NOA 16-0314.08
 B) ROOF TILE UNDERLAYMENT NOA 15-0410.04.
 C) ROOF VENTS FL16588-R1 AND NOA 13-0122.07
 D) ROOF TILE ADHESIVE FL6332-R5.

Review Stop Z ZONING
Rev No 1 Status P Date 2017-03-03 Cont ID  
Sent By njwira Date 2017-03-03 Time 12:02 Rev Time 0.00
Received By njwira Date 2017-03-03 Time 10:22 Sent To  
Notes
2017-03-03 12:08:253/3/17- PASSED
  
 IBIS RESIDENTIAL PLANNED DEVELOPMENT ZERO LOT LINE
 LANDSCAPE PLAN APPROVED
 ONE KITCHEN ONE UNIT
 BUILDING HEIGHT 14FT. 8IN. MEETS HEIGHT LIMITS
 ZERO SIDE SETBACK IS 8FT. MEETING 0FT. REQUIREMENT
 SIDE SETBACK IS 15.69FT. MEETING 8FT. REQUIREMENT
 A/C UNIT DOESN'T PROJECT INTO A REQUIRED SETBACK
 FRONT SETBACK IS 45.47FT. MEETING 10FT. REQUIREMENT
 REAR SETBACK IS 45.07FT. MEETING 10FT. REQUIREMENT
 DRIVEWAY IS 18FT. WIDE MEETING 20FT. LIMIT
 5FT. 2IN SIDE SETBACK MEETS 3FT. REQUIREMENT
 REQUIRED PERVIOUS SURFACE IN THE FRONT SETBACK IS
 577.5SQFT.
 PROPOSED 590SQFT.
 SCREEN ENCLOSURE HAS A 15.69SQFT. SIDE SETBACK MEETING
 3FT. REQUIREMENT
 REAR SETBACK FOR A SCREEN ENCLOSURE IS 38.85FT. MEETING
 3FT. REQUIREMENT
  
  
 PLEASE CONTACT
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved