Plan Review Details - Permit 17021032
Plan Review Stops For Permit 17021032
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-02-20 Cont ID  
Sent By cthroop Date 2018-02-20 Time 10:39 Rev Time 0.00
Received By cthroop Date 2018-02-20 Time 07:41 Sent To Z
Notes
2018-02-20 10:40:37SENT TO ZONING (LL). CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-10-05 Cont ID  
Sent By cthroop Date 2017-10-05 Time 15:56 Rev Time 0.00
Received By cthroop Date 2017-10-03 Time 08:24 Sent To P
Notes
2017-10-05 16:17:31BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IT IS RECOMMENDED THAT A SEPERATE PERMIT BE ISSUED
 FOR THE GUEST HOUSE. THIS IS NOT MANDATORY BUT MAY
 ASSIST IN OBTAINING A CERTIFICATE OF OCCUPANCY FOR THE
 PRIMARY RESIDENCE.
 2. OWNER/AGENT TO SIGN ENERGY SUBMITTALS.
 3. PROVIDE FOUNDATION PLAN FOR GENERATOR, INCLUDE AN
 ATTACHMENT DETAIL. ALSO PROVIDE THE MANUFACTURERS
 INSTALLATION INSTRUCTIONS FOR THE SPECIFIC GENERATOR TO
 BE INSTALLED.
 4. PROVIDE ICC-ES REPORT FOR THE ICYNENE INSULATION.
 IDENTIFY WHICH PRODUCT WILL BE INSTALLED. MANUFACTURERS
 INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT TIME OF
 INSTALLATION.
 5. PROVISOS FOR PRODUCT APPROVALS ARE ALLOWED. PLEASE
 PROVIDE A LIST, REVIEWED AND APPROVED BY DESIGN
 PROFESSIONAL OF ALL PRODUCTS TO BE DEFFERRED. THESE
 DOCUMENTS SHALL BE REVIEWED AND APPROVED PRIOR TO
 INSTALLATION. ALL OTHER SUBMITTAL DOCUMENTS SHALL BE
 INCLUDED AT TIME OF PERMIT.
 6. PROVIDE ELEVATION CERTIFICATE.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 8.0 FEET NGVD.
  
 AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 RECOMMENDED.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-04-17 Cont ID  
Sent By cthroop Date 2017-04-17 Time 07:28 Rev Time 0.00
Received By cthroop Date 2017-04-13 Time 16:41 Sent To  
Notes
2017-04-17 07:53:57BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 2. NFIP - PROJECT IS LOCATED IN FLOOD ZONE A5.
 3. PROVIDE SITE PLAN WITH SITE DRAINAGE.
 4. ROOFING - SEPERATE PERMIT REQUIRED.
 5. PROVIDE SHORING PLAN FOR C.I.P. 2ND FLOOR AND ROOF.
 6. PROVIDE PRODUCT APPROVALS FOR THE FOLLOWING:
 SKYLIGHTS, ROOFTOP GLASS RAILING, OVERHEAD DOORS.
 7. PROVIDE SHOP DRAWINGS/ SPECIFICATIONS AND/OR
 MANUFACTURERS INSTALLATION INSTRUCTIONS FOR THE
 FOLLOWING:
 SPIRAL STAIRCASE, FIREPLACES, ALUMINUM EYBROWS,
 ELEVATOR, SOLAR PV PANELS, SOLAR WATER HEATER, 2ND
 FLOOR LIFT, FIRE PITS, GLASS STAIR RAILS/GUARDS, BBQ
 GRILL, WATER PROOF MEMBRANE FOR ELEVATOR PIT AND CAR
 LIFTS.
 8. PLAN SHEET A-5.6 INDICATES A 4 CAR GARAGE, PLAN
 SHEET A-2.1 INDICATES A 3 CAR GARAGE. PLEASE CLARIFY.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7FT. 6 INCHES.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE)
 REQUIRES AN ADDITIONAL 6 INCHES OF FREEBOARD REQUIRING
 THE DESIGN FLOOD ELEVATION (DFE) TO BE 8. 0 FEET.
 PLEASE INSERT THIS INFORMATION ON YOUR PLANS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING,
 WINDOW, AND DOOR SUBMITTALS.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-10-03 Cont ID  
Sent By jleahy Date 2017-10-03 Time 12:30 Rev Time 0.00
Received By jleahy Date 2017-10-03 Time 12:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-09 Cont ID  
Sent By jleahy Date 2017-03-09 Time 10:18 Rev Time 0.00
Received By jleahy Date 2017-03-09 Time 10:18 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2017-11-29 Cont ID  
Sent By shill Date 2017-11-29 Time 08:57 Rev Time 0.00
Received By shill Date 2017-11-29 Time 08:57 Sent To  
Notes
2017-11-29 08:58:49OK PER EMAIL FROM VINCE NOEL DATED 11/29/17
 CREATED PDF OF EMAIL CHAIN AND SENT TO FILENET
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2017-11-28 Cont ID  
Sent By shill Date 2017-11-28 Time 06:34 Rev Time 0.00
Received By shill Date 2017-11-28 Time 06:34 Sent To  
Notes
2017-11-28 06:34:52FAILED PENDING RESPONSE FROM ENGINEERING RE: UNITY OF
 TITLE, CONSTRUCTION IN UTILITY EASEMENT
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2018-03-01 Cont ID  
Sent By gjohnson Date 2018-03-01 Time 12:06 Rev Time 0.00
Received By gjohnson Date 2018-03-01 Time 11:27 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2017-10-06 Cont ID  
Sent By gjohnson Date 2017-10-06 Time 14:00 Rev Time 0.00
Received By gjohnson Date 2017-10-06 Time 14:00 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-03-14 Cont ID  
Sent By gjohnson Date 2017-03-14 Time 10:55 Rev Time 0.00
Received By gjohnson Date 2017-03-14 Time 10:55 Sent To  
Notes
2017-03-14 10:59:461ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 1. SHOW DISTANCE FROM REG. TO APPLIANCE. PER FBC 2014
 FUEL GAS CODE SEC. 402.4.1.
  
 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND
 TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE
 SEC. 502 THRU 505.
  
 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-01 Cont ID  
Sent By gjohnson Date 2018-03-01 Time 12:07 Rev Time 0.00
Received By gjohnson Date 2018-02-15 Time 09:50 Sent To  
Notes
2018-02-16 09:50:13RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-28 Cont ID  
Sent By shill Date 2017-11-28 Time 06:34 Rev Time 0.00
Received By shill Date 2017-09-07 Time 07:39 Sent To  
Notes
2017-09-07 12:44:03R41

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-17 Cont ID  
Sent By cthroop Date 2017-04-17 Time 07:28 Rev Time 0.00
Received By cthroop Date 2017-02-23 Time 13:48 Sent To  
Notes
2017-02-24 13:49:07R30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2017-04-14 Cont ID  
Sent By cthroop Date 2017-04-14 Time 07:35 Rev Time 0.00
Received By cthroop Date 2017-04-13 Time 16:41 Sent To  
Notes
2017-04-14 07:36:26FEES PAID 1/20/17

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-11-16 Cont ID  
Sent By rmcdouga Date 2017-11-16 Time 18:32 Rev Time 0.00
Received By rmcdouga Date 2017-11-16 Time 17:39 Sent To I
Notes
2017-11-16 19:06:25PROVIDE ROOF STAND PRODUCT APPROVALS TO THE INSPECTOR
 IN THE FIELD.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-12 Cont ID  
Sent By hmoser Date 2017-04-12 Time 15:52 Rev Time 0.00
Received By hmoser Date 2017-04-11 Time 16:12 Sent To  
Notes
2017-04-12 15:52:23PLAN DENIED
 1) AHU # 2 REFER TO SECTION M1602.2 PROHIBITED
 SOURCES # 1 RETURN AIR IN KITCHEN MUST BE 10 FT.
 FROM ANY APPLIANCE.2014 FRC
 2) PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS
 ON THE KITCHEN HOOD AT FIRST INSPECTION.
 3) AHU # 3 PROVIDE SIZE OF GRILL IN FOYER ON THE PLAN.
 4) SHOW LOCATION OF ALL 6 CONDENSERS ON THE PLAN
 SECTION 107-FBC.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2018-02-20 Cont ID  
Sent By cthroop Date 2018-02-20 Time 10:39 Rev Time 0.00
Received By cthroop Date 2018-02-20 Time 08:27 Sent To  
Notes
2021-03-27 11:08:47NFIP REVIEW COMMENTS:
 PROVIDE BUILDING UNDER CONSTRUCTION ELEVATION
 CERTIFICATE AT PLACEMENT OF 1ST FLOOR.
 PROVIDE FINISHED CONSTRUCTION ELEVATION CERTIFICATE
 PRIOR TO C/O.
 CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2017-10-05 Cont ID  
Sent By cthroop Date 2017-10-05 Time 15:53 Rev Time 0.00
Received By cthroop Date 2017-10-03 Time 10:12 Sent To  
Notes
2017-10-05 15:55:30BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ELEVATION CERTIFICATE REQUIRED PRIOR TO ISSUANCE OF
 PERMIT.
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET NGVD 29.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4658-16 (EFF. DATE 9-12-2016), REQUIRES AN ADDITIONAL 2
 FEET OF FREEBOARD REQUIRING THE DESIGN FLOOD ELEVATION
 (DFE) TO BE 9.0 FEET NGVD 29. PLEASE NOTE THIS
 INFORMATION ON YOUR PLANS.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 9.0 FEET NGVD 29.
  
 AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 RECOMMENDED.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2017-04-14 Cont ID  
Sent By cthroop Date 2017-04-14 Time 09:21 Rev Time 0.00
Received By cthroop Date 2017-04-13 Time 16:41 Sent To  
Notes
2017-04-14 09:52:13BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). THE SPECIFIC ZONE DESIGNATION FOR THIS SITE IS
 A5 WITH A BASE FLOOD ELEVATION (BFE) OF 7 FEET, NGVD
 29. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4658-16, (EFF. DATE 9-12-2016), REQUIRES AN ADDITIONAL
 2 FEET OF FREEBOARD REQUIRING THE DESIGN FLOOD
 ELEVATION (DFE) TO BE 9. 0 FEET NGVD 29. PLEASE INSERT
 THIS INFORMATION ON YOUR PLANS.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
 NOTE: ALL EQUIPMENT SERVICING THE BUILDINGS ON THIS
 SITE ARE REQUIRED TO BE AT OR ABOVE 9.0 FEET NGVD.
  
 AN UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 RECOMMENDED.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 1612.1 GENERAL.
 WITHIN FLOOD HAZARD AREAS AS ESTABLISHED IN SECTION
 1612.3, ALL NEW CONSTRUCTION OF BUILDINGS, STRUCTURES
 AND PORTIONS OF BUILDINGS AND STRUCTURES, INCLUDING
 SUBSTANTIAL IMPROVEMENT AND RESTORATION OF SUBSTANTIAL
 DAMAGE TO BUILDINGS AND STRUCTURES, SHALL BE DESIGNED
 AND CONSTRUCTED TO RESIST THE EFFECTS OF FLOOD HAZARDS
 AND FLOOD LOADS. FOR BUILDINGS THAT ARE LOCATED IN MORE
 THAN ONE FLOOD HAZARD AREA, THE PROVISIONS ASSOCIATED
 WITH THE MOST RESTRICTIVE FLOOD HAZARD AREA SHALL
 APPLY.
  
 1612.4 DESIGN AND CONSTRUCTION.
 THE DESIGN AND CONSTRUCTION OF BUILDINGS AND STRUCTURES
 LOCATED IN FLOOD HAZARD AREAS, INCLUDING COASTAL HIGH
 HAZARD AREAS, SHALL BE IN ACCORDANCE WITH CHAPTER 5 OF
 ASCE 7 AND WITH ASCE 24.
  
 FBC 107.3.5.3 RESIDENTIAL (ONE AND TWO-FAMILY) &
 R322.2.1 ELEVATION REQUIREMENTS. BUILDINGS AND
 STRUCTURES IN FLOOD HAZARD AREAS NOT DESIGNATED AS
 COASTAL A ZONES SHALL HAVE THE LOWEST FLOORS ELEVATED
 TO OR ABOVE THE DESIGN FLOOD ELEVATION. PROVIDE FLOOD
 DESIGN INFORMATION ON THE PROPOSED SURVEY AND PROVIDE
 FLOOD ELEVATION CERTIFICATE.
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-03-01 Cont ID  
Sent By gjohnson Date 2018-03-01 Time 12:06 Rev Time 0.00
Received By gjohnson Date 2018-03-01 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-10-06 Cont ID  
Sent By gjohnson Date 2017-10-06 Time 14:00 Rev Time 0.00
Received By gjohnson Date 2017-10-05 Time 16:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-03-14 Cont ID  
Sent By gjohnson Date 2017-03-14 Time 10:51 Rev Time 0.00
Received By gjohnson Date 2017-03-13 Time 15:33 Sent To  
Notes
2017-03-14 10:54:571ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE A WATER RISER DIAGRAM. PER WPB AMEND
 TO FBC 107.3.5.3(11)
  
 2. THE DRAIN FOR THE JACUZZI ON ROOF NOT SHOWN PLEASE
 CLARIFY. WPB AMEND TO FBC 107.2.1
  
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-10-05 Cont ID  
Sent By cthroop Date 2017-10-05 Time 15:52 Rev Time 0.00
Received By cthroop Date 2017-10-05 Time 15:52 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-04-14 Cont ID  
Sent By cthroop Date 2017-04-14 Time 13:28 Rev Time 0.00
Received By cthroop Date 2017-04-13 Time 16:41 Sent To  
Notes
2017-04-14 13:30:10BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM
 COMPONENTS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-02-22 Cont ID  
Sent By llouie Date 2018-02-22 Time   Rev Time 0.00
Received By llouie Date 2018-02-21 Time   Sent To P
Notes
2018-02-22 15:24:14SEPERATE PERMITS REQUIRED FOR: LANDSCAPING, SWIMMING
 POOL, DRIVEWAY AND WALKWAYS/PAVERS.
  
 NOTES:
  
 - SEE ATTACHMENTS FOR SUPPORTING EMAILS.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2017-10-23 Cont ID  
Sent By llouie Date 2017-10-23 Time   Rev Time 0.00
Received By llouie Date 2017-10-20 Time   Sent To  
Notes
2017-10-23 13:03:51** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE SURVEY PROVIDED SHOWS THAT THERE ARE UTILITY
 EASEMENTS RUNNING THROUGH THE PROPERTY. STRUCTURES
 CANNOT BE BUILT OVER ANY UTILITY EASEMENTS.
  
 2.) THE SURVEY SHOWS THAT THERE ARE TWO (2) PARCELS
 ASSOCIATED WITH THE PROPERTY. A UNITY OF TITLE MAY BE
 REQUIRED. A STOP HAS BEEN ADDED FOR THE ENGINEERING
 SERVICES DEPARTMENT TO REVIEW THE PLANS.
  
 3.) THE PLANS SHOW A KITCHEN IN THE GUEST BEDROOM ON
 THE SECOND FLOOR. NO MORE THAN ONE (1) KITCHEN FACILITY
 SHALL BE PROVIDED FOR THE OVERALL PROJECT. ALL PLANS
 SHOULD BE CORRECTED FOR CONSISTENCY.
  
 4.) PROVIDE ADDITIONAL INFORMATION ON THE ARCHITECTURAL
 FEATURES THAT ARE LOCATED ABOVE THE MAXIMUM ALLOWABLE
 HEIGHT IN THE DISTRICT. THE ARCHITECTURAL FEATURES SEEM
 TO BE ENCLOSED SPACES, WHICH DOES NOT QUALIFY AS AN
 ARCHITECTURAL FEATURES.
  
 5.) DETAILS AND DIMENSIONS OF THE PROPOSED MOTORIZED
 GATE ALONG FOREST HILL BOULEVARD NOT PROVIDED WITH THE
 RESUBMITTAL. PLEASE PROVIDE.
  
  
 NOTES:
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENT.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  
 * SURVEY SUBMITTED WITH RESUBMITTAL #2. ENGINEERING
 REVIEW STOP ADDED FOR ENGINEERING DEPT. TO REVIEW
 SURVEY AND PROPOSED DEVELOPMENT.
  
 * NO KITCHEN FACILITY SHALL BE PERMITTED IN THE GUEST
 ROOM LOCATED ON THE SECOND FLOOR. THIS SHALL BE
 CORRECTED ON ALL PLAN SHEETS FOR CONSISTENCY.
  

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2017-03-03 Time   Rev Time 0.00
Received By llouie Date 2017-03-02 Time 15:52 Sent To  
Notes
2017-03-03 13:27:00** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) A SURVEY OF THE PROPERTY IS REQUIRED.
  
 2.) SITE PLAN SHOULD CLEARLY ILLUSTRATE/PROVIDE THE
 FOLLOWING INFORMATION:
 - NORTH ARROW.
 - DATA TABLE SUPPLING THE FOLLOWING INFORMATION: ZONING
 OF THE PROPERTY; TOTAL ACRES OF THE PROJECT; TOTAL
 GROSS BUILDING SQUARE FOOTAGE; AMOUNT OF OPEN SPACE,
 LANDSCAPING, BUILDING COVERAGE AND IMPERMEABLE SURFACE
 IN PERCENTAGES AND IN SQUARE FEET; PARKING COMPUTATIONS
 (PARKING REQUIRED, PROVIDED, ETC.)
 - LOT DIMENSIONS AS PROVIDED IN THE SURVEY OF THE
 PROPERTY.
 - DIMENSIONS OF ALL DRIVEWAYS
 - SETBACK DIMENSION FROM ALL PROPOSED STRUCTURES TO THE
 PROPERTY LINE.
  
 3.) THE PROPOSED RESIDENTIAL STRUCTURE SEEMS TO BE
 ENCROACHING INTO THE 5 FT. SIDE SETBACK ALONG THE NORTH
 PROPERTY LINE. PLEASE ADDRESS. [ZLDR S.94-72(A)(2)]
  
 4.) THE MAXIMUM HEIGHT OF THE PROPOSED RESIDENTIAL
 STRUCTURE FROM THE GROUND TO THE TOP OF THE STRUCTURE
 IS 30 FT. THE ELEVATIONS INDICATE THAT THE HEIGHT OF
 THE STRUCTURE EXCEEDS THE MAXIMUM ALLOWABLE HEIGHT (>33
 FT.). PLEASE ADDRESS. [ZLDR S.94-72(A)(3)]
  
 5.) THE PLAN SHOWS MULTIPLE KITCHENS PROPOSED ON
 DIFFERENT LEVELS OF THE RESIDENTIAL STRUCTURE; HOWEVER,
 THE SF7 ZONING DISTRICT ALLOWS ONLY ONE (1) KITCHEN IN
 THE PROPOSED RESIDENTIAL STRUCTURE.
  
 6.) PROVIDE DETAILS AND DIMENSIONS OF THE PROPOSED
 MOTORIZED GATE ALONG FOREST HILL BOULEVARD.
  
 7.) MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO
 THE POOL EQUIPMENT AND GENERATOR, MAY NOT PROJECT MORE
 THAN 4 FT. INTO A SETBACK. [ZLDR S.94-305(A)(4)]
  
 8.) PROVIDE VISIBILITY TRIANGLES IN ACCORDANCE WITH
 ZLDR S.94-305(E) TO ENSURE THAT INTERSECTION VISIBLE IS
 NOT OBSCURED BY THE PROPOSED WALL.
  
 9.)THE SITE PLAN (SHEET A1.1) SHOWS TWO DRIVEWAYS ON
 FOREST HILL BOULEVARD. THIS IS NOT PERMITTED. ONLY ONE
 (1) DRIVEWAY WITH A WIDTH OF NO GREATER THAN 20 FT. AT
 THE PROPERTY LINE SHALL BE PROVIDED ON FOREST HILL
 BOULEVARD. ALTERNATIVELY, ONE (1) 10 FT. WIDE DRIVEWAY
 ON FOREST HILL BOULEVARD AND ONE (1) 10 FT. WIDE
 DRIVEWAY ON FLAGLER DRIVE CAN BE PROVIDED. [ZLDR
 S.94-313(1)C.]
  
 10.) A SEPARATE PERMIT FOR LANDSCAPING IS REQUIRED AND
 SHALL BE SUBMITTED CONCURRENTLY WITH THIS PERMIT.
  
 REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458
 IF THERE ARE QUESTIONS.