Plan Review Details - Permit 17020757
| Plan Review Stops For Permit 17020757 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-03 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-03 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-03-09 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-09 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2017-03-09 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-02-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-02-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-02-24 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-21 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-16 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-21 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2017-03-21 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-21 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-05-09 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-05-09 |
Time |
06:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-15 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-03-14 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2017-03-15 11:21:50 | 1) SHT. A5.1 - WALL FINISHES - 2014 FBC | | | SEC.1210.2.2.WALLS AND PARTITIONS WITHIN 2 FEET OF | | | SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF NOT | | | LESS THAN 4 FEET ABOVE THE FLOOR. THE TABLE NOTES | | | "PAINT". CLARIFY. | | | 2) SHT. A5.1 - DETAIL #7 REFERS TO DETAIL #5 ON A5.1 | | | FOR RIM HEIGHT OF LAVATORY. DETAIL #5 DOES NOT SHOW A | | | LAVATORY. SEE DETAIL #6 ALSO.CLARIFY. | | | 3) SHT. A5.1 - THE HEIGHT OF THE GRAB BARS SHALL BE | | | MEASURED TO THE TOP OF THE GRIPPING SURFACE PER 2014 | | | FBC -ACCESS. SEC.609.4. | | | 4) SHT. A5.1 - DETAIL #2 & #3 - SHOW THE LENGTH AND | | | WIDTH DIMENSIONS OF THE HANDICAP ACCESSIBLE STALLS. | | | COMPLY WITH FL. ACCESS. CODE. | | | 5) THE COVER SHEET C1 LISTS PLUMBING SHEETS P1, P1.1, | | | P2, P3, P3.2, & GP1. THESE SHEETS ARE NOT INCLUDED IN | | | THE PLAN SET. A THOROUGH PLUMBING PLAN REVIEW CANNOT BE | | | DONE WITHOUT THESE SHEETS. SUBMIT ALL REQUIRED SHEETS | | | FOR REVIEW. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
|