Plan Review Details - Permit 17020752
| Plan Review Stops For Permit 17020752 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2017-12-07 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-12-07 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-12-07 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-12-07 14:00:47 | PROVISO: SUPPLY A TEST PORT (MINI MANHOLE OR LARGE | | | CLEANOUT) | | | | | | | | | MANNY GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-02-28 |
|
|
Cont ID |
|
| Sent By |
MGONZALE |
Date |
2017-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2017-02-28 |
Time |
12:29 |
Sent To |
I |
|
| Notes |
| 2017-02-28 12:32:13 | ADDRESS PLANNING COMMENTS: | | | | | | 1. LOCATION OF THE GREASE SEPARATOR UNKNOWN. | | | YOU MAY SUPPLY A SURVEY OR LOCATION SKETCH | | | | | | MGONZALEZ | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-12-07 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-11-07 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2017-11-08 13:36:20 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-02-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-02-28 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-02-16 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2017-02-17 09:35:23 | ROUTED TO PLUMB<5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-16 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-16 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-02-18 |
Time |
03:35 |
Rev Time |
0.00 |
| Received By |
mgonzale |
Date |
2017-02-18 |
Time |
03:14 |
Sent To |
|
|
| Notes |
| 2017-02-18 03:35:27 | 1) SUBMIT SIZING CALCULATIONS FOR THE INTERCEPTOR. | | | COMPLY WITH F.A.C. 64E-6 OR PDI STANDARD G101. | | | 2) GREASE INTERCEPTOR CAPACITY SHALL COMPLY WITH 2014 | | | FBC-PLUMBING SEC.1003.3.4.1 & TABLE 1003.3.4.1. | | | 3) INDICATE ON THE SUBMITTED SPECIFICATION SHEET WHICH | | | MODEL OF THE GREASE TRAP IS BEING INSTALLED. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 4) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF THE | | | INTERCEPTOR.WPB AMEND. TO FBC SEC. 107.2.1. | | | 5) SUBMIT A SANITARY RISER DIAGRAM SHOWING HOW THIS | | | WILL BE CONNECTED TO THE SANITARY SYSTEM. | | | 6) IS THIS REPLACING AN EXISTING UNIT OR IS THIS A NEW | | | INSTALLLATION. INDICATE SUCH ON THE REQUIRED FLOOR | | | PLAN. | | | 7) WHAT TYPE OF FIXTURE(S) IS DISCHARGING INTO THIS | | | INTERCEPTOR? SHOW ON THE REQUIRED FLOOR PLAN. | | | 8) SINKS USED FOR THE WASHING, RINSING OR SANITIZING OF | | | UTENSILS,DISHES, POTS, PANS OR SERVICE WARE USED IN THE | | | PREPARATION, SERVING OR EATING OF FOOD SHALL DDISCHARGE | | | INDIRECTLY THROUGH AN AIR GAP OR AIR BREAK TO THE | | | DRAINAGE SYSTEM. 2014 FBC-PLUMBING SEC.802.1.8. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
|