| Plan Review Stops For Permit 17020696 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-09 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-09 |
Time |
14:12 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-25 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-25 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2017-04-25 07:49:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LIST: | | | | | | 4. FBC 1609, PROVIDE WIND DESIGN CRITERIA FBC 1603.1.4. | | | | | | 5. OK | | | | | | 6. FBC 107, WHEN RESUBMITTING APPLICANT IS TO PREPARE | | | TWO IDENTICAL COLLATED SETS OF PERMIT DOCUMENTS FOR | | | PERMIT ISSUANCE. | | | | | | OLD SHEETS ARE TO BE RETAINED IN THE SUBMITTAL, REMOVED | | | FROM THE TWO PERMIT ISSUE SETS, AND THOSE DOCUMENTS | | | SHOULD BE MARKED "VOID" OR "OLD SHEETS". | | | | | | THE TWO COLLATED PERMIT SETS ARE TO INCLUDE ANY | | | DOCUMENTS PREVIOUSLY SUBMITTED AND REVIEWED AS WELL AS | | | THE NEW DOCUMENTS WHICH SHOULD ADDRESS ALL COMMENTS. | | | | | | A RESPONSE LETTER STATING HOW EACH ITEM WAS ADDRESSED | | | WILL HELP TO EXPEDITE YOUR PLAN REVIEW. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-23 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-23 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2017-03-23 17:47:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LIST: | | | | | | 1. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, FBC | | | 109. THE VALUE IS TO INCLUDE LABOR, MATERIALS, OVERHEAD | | | AND PROFIT, EVEN IF PROVIDED BY OTHERS. IF THIS IS A | | | LABOR ONLY CONTRACT, PROVIDE THE INVOICES FOR THE | | | MATERIALS AS WELL AS THE CONTRACT. | | | | | | 2-3. OK | | | | | | 4. FBC 1609, PROVIDE A STRUCTURAL DETAIL FOR THE | | | INSTALLATION, INCLUDING WIND DESIGN CRITERIA FBC | | | 1603.1.4. | | | | | | SEE MECHANICAL COMMENTS REGARDING ADDITIONAL | | | INFORMATION REQUIRED FOR A COMPLETE STRUCTURAL DETAIL. | | | | | | I WAS NOT ABLE TO LOCATE WIND SPEED ON THE PLAN; EITHER | | | ADD OR ADVISE WHERE THIS CAN BE FOUND. | | | | | | 5. OK | | | | | | 6. FBC 107, WHEN RESUBMITTING APPLICANT IS TO PREPARE | | | TWO IDENTICAL COLLATED SETS OF PERMIT DOCUMENTS FOR | | | PERMIT ISSUANCE. | | | | | | OLD SHEETS ARE TO BE RETAINED IN THE SUBMITTAL, REMOVED | | | FROM THE TWO PERMIT ISSUE SETS, AND THOSE DOCUMENTS | | | SHOULD BE MARKED "VOID" OR "OLD SHEETS". | | | | | | THE TWO COLLATED PERMIT SETS ARE TO INCLUDE ANY | | | DOCUMENTS PREVIOUSLY SUBMITTED AND REVIEWED AS WELL AS | | | THE NEW DOCUMENTS WHICH SHOULD ADDRESS ALL COMMENTS. | | | | | | A RESPONSE LETTER STATING HOW EACH ITEM WAS ADDRESSED | | | WILL HELP TO EXPEDITE YOUR PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-03 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2017-03-03 09:11:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB, FBC | | | 109. THE VALUE IS TO INCLUDE LABOR, MATERIALS, OVERHEAD | | | AND PROFIT, EVEN IF PROVIDED BY OTHERS. IF THIS IS A | | | LABOR ONLY CONTRACT, PROVIDE THE INVOICES FOR THE | | | MATERIALS AS WELL AS THE CONTRACT. | | | | | | 2. ADVANCED FBC COURSE IS REQUIRED FOR ALL ENGINEERS | | | DESIGNING USING THE FLORIDA BUILDING CODE, FS 471.0195 | | | BY JUNE 30, 2016. EVIDENCE THAT THE COURSE HAS BEEN | | | COMPLETED IS TO BE SENT TO FBPE AND THE WEBSITE | | | (WWW.MYFLORIDALICENSE.COM) IS TO BE UPDATED. | | | | | | THIS COMMENT WILL NOT PREVENT THE PERMIT FROM BEING | | | ISSUED. | | | | | | 3. FBC 1601, REVISE PLAN TO INCLUDE WEIGHT OF EXISTING | | | UNIT, PROPOSED NEW UNIT. IT IS NOT CLEAR WHETHER THE | | | LOAD ONTO THE EXISTING STRUCTURE WILL BE THE SAME, | | | MORE, OR LESS THAN THE EXISTING. | | | | | | 4. FBC 1609, PROVIDE A STRUCTURAL DETAIL FOR THE | | | INSTALLATION, INCLUDING WIND DESIGN CRITERIA FBC | | | 1603.1.4. | | | | | | 5. AN AREA IS LABELED "EQUIPMENT ROOM". IT IS NOT CLEAR | | | WHETHER THIS IS EXISTING OR PROPOSED, AND IS THIS A | | | ROOM AND CONSIDERED ANOTHER STORY AND INTEGRAL TO THE | | | BUILDING, OR IS THIS IS AN EQUIPMENT SHELTER, PREFAB, | | | FBC 1509? NOT ENOUGH INFORMATION PROVIDED TO DETERMINE | | | CODE COMPLIANCE. | | | | | | 6. FBC 107, WHEN RESUBMITTING APPLICANT IS TO PREPARE | | | TWO IDENTICAL COLLATED SETS OF PERMIT DOCUMENTS FOR | | | PERMIT ISSUANCE. | | | | | | OLD SHEETS ARE TO BE RETAINED IN THE SUBMITTAL, REMOVED | | | FROM THE TWO PERMIT ISSUE SETS, AND THOSE DOCUMENTS | | | SHOULD BE MARKED "VOID" OR "OLD SHEETS". | | | | | | THE TWO COLLATED PERMIT SETS ARE TO INCLUDE ANY | | | DOCUMENTS PREVIOUSLY SUBMITTED AND REVIEWED AS WELL AS | | | THE NEW DOCUMENTS WHICH SHOULD ADDRESS ALL COMMENTS. | | | | | | A RESPONSE LETTER STATING HOW EACH ITEM WAS ADDRESSED | | | WILL HELP TO EXPEDITE YOUR PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-03-21 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-21 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-21 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-03-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-06 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-06 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2017-03-06 10:18:40 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. ADD A GENERAL NOTE TO PROVIDE PER FBC EC 405.7.4- | | | COMPLETION DOCUMENTS PER CODE SECTION. FBC EC 405.7.3- | | | VOLTAGE DROP NEW FEEDERS AND BRANCH CIRCUITS. | | | 2. PROVIDE GENERAL NOTES TO ELECTRICAL RISER DIAGRAM TO | | | INDICATE NEC 110.24- AVAILABLE FAULT CURRENT- FIELD | | | MARKINGS; MODIFICATIONS SEE VERBIAGE IN CODE. | | | 3. PROVIDE ACTUAL REVISED CALCULATIONS FOR THE PANEL | | | BOARDS SHOWN WITH CHANGES, DP, A, B. | | | 4. PLEASE ADDRESS BUILDING, FIRE AND MECHANICAL | | | COMMENTS RELATED TO ELECTRICAL. | | | 5. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-04-26 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2017-04-26 12:12:53 | PASSED AND RETURNED TO B19, CONTACTED RACHAEL, | | | APPLICANT. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-03-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-20 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-02-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-02-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-02-23 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2017-02-23 17:33:51 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE CONSTRUCTION AND INSPECTION OF THE WATER COOLING | | | TOWER SHALL COMPLY WITH NFPA 214, STANDARD ON | | | WATER-COOLING TOWERS, 2011 EDITION. | | | | | | THERE IS INSUFFICIENT DETAIL PROVIDED TO COMPLETE A | | | REVIEW. | | | | | | | | | 2) | | | CHAPTER 4 LOCATION OF WATER-COOLING TOWERS | | | 4.1 CONSTRUCTION MATERIALS OF WATER-COOLING TOWERS. | | | 4.1.1 WHERE THE COOLING TOWER?S STRUCTURE, FAN, | | | DISTRIBUTION SYSTEM, LOUVERS, AND FILL AND DRIFT | | | ELIMINATOR MATERIALS ARE ALL OF NONCOMBUSTIBLE | | | MATERIALS, A FIRE PROTECTION SYSTEM SHALL NOT BE | | | REQUIRED. | | | 4.1.2 IF ANY OF THE CONSTRUCTION MATERIALS ARE | | | COMBUSTIBLE AND THE FACTORS IN SECTION 4.2 NECESSITATE | | | IT, FIRE PROTECTION SHALL BE PROVIDED IN ACCORDANCE | | | WITH CHAPTER 5, AND TOWERS SHALL BE LOCATED IN | | | ACCORDANCE WITH CHAPTER 4. | | | | | | | | | | | | 3) | | | 4.8 SCREENING. | | | 4.8.1 OPEN AREAS OR SPACE BETWEEN A COMBUSTIBLE | | | COLD-WATER BASIN AND THE GROUND OR ROOF OF A BUILDING | | | UPON WHICH IT IS LOCATED SHALL BE EFFECTIVELY SCREENED | | | TO PREVENT THE ACCUMULATION OF WASTE COMBUSTIBLE | | | MATERIAL UNDER THE TOWER AND TO | | | PREVENT THE USE OF SUCH AREAS OR SPACE UNDER THE TOWER | | | FOR THE STORAGE OF COMBUSTIBLE MATERIAL. | | | 4.8.2 FIRE PROTECTION SHALL BE PERMITTED TO BE | | | INSTALLED IN LIEU OF SCREENING. | | | | | | | | | 4) | | | 5.2.9 PROTECTION FOR FAN DRIVE MOTOR. | | | 5.2.9.1 A SPRINKLER OR SPRAY NOZZLE SHALL BE PROVIDED | | | OVER EACH FAN DRIVE MOTOR WHERE THE MOTOR IS LOCATED SO | | | THAT IT IS NOT WITHIN THE PROTECTED AREA OF THE TOWER. | | | | | | | | | 5) | | | 5.2.10 EXPOSURE PROTECTION. | | | 5.2.10.1 WHERE ANY COMBUSTIBLE EXTERIOR SURFACES OF A | | | TOWER, INCLUDING THE FAN DECK AND DISTRIBUTION BASINS, | | | ARE LESS THAN 100 FT (30.5 M) FROM SIGNIFICANT | | | CONCENTRATIONS OF COMBUSTIBLES SUCH AS STRUCTURES OR | | | PILED MATERIAL, THE COMBUSTIBLE EXPOSED SURFACES OF THE | | | TOWER SHALL BE PROTECTED BY AN AUTOMATIC WATER SPRAY | | | SYSTEM. | | | 5.2.10.2 SYSTEMS FOR EXTERIOR PROTECTION SHALL BE | | | DESIGNED WITH THE SAME ATTENTION AND CARE AS INTERIOR | | | SYSTEMS. | | | 5.2.10.2.1 PIPE SIZING SHALL BE BASED ON HYDRAULIC | | | CALCULATIONS. | | | 5.2.10.2.2 WATER SUPPLY AND DISCHARGE RATE SHALL BE | | | BASED ON A MINIMUM 0.15 GPM/FT2 (6.11 MM/MIN) FOR ALL | | | PROTECTED SURFACES | | | | | | | | | 6) | | | 5.7* LIGHTNING PROTECTION. LIGHTNING PROTECTION, WHERE | | | PROVIDED, SHALL BE INSTALLED IN ACCORDANCE WITH THE | | | PROVISIONS OF NFPA 780. | | | | | | | | | 7) | | | CHAPTER 6 ELECTRICAL EQUIPMENT AND WIRING | | | 6.1 INSTALLATION. INSTALLATION OF ALL ELECTRICAL | | | EQUIPMENT AND WIRING PERTAINING TO WATER-COOLING TOWERS | | | SHALL BE IN ACCORDANCE WITH NFPA 70. | | | 6.2* OVERCURRENT PROTECTION. ELECTRIC MOTORS THAT ARE | | | DRIVING FANS SHALL BE PROVIDED WITH OVERCURRENT | | | PROTECTION DEVICES AS MANDATED BY NFPA 70. | | | | | | | | | 8) | | | 6.3 STOP FAN. A REMOTE FAN MOTOR SWITCH SHALL BE | | | PROVIDED TOSTOP THE FAN IN CASE OF FIRE. | | | 6.4 INTERLOCK. WHEN A FIRE PROTECTION SYSTEM IS | | | INSTALLED, PROVISIONS SHALL BE MADE TO INTERLOCK THE | | | FAN MOTORS WITH THE FIRE PROTECTION SYSTEM AS SET FORTH | | | IN CHAPTER 5. | | | 6.5 VIBRATION-CONTROLLED SWITCH. A LISTED, AUTOMATIC, | | | VIBRATIONCONTROLLED SWITCH SHALL BE PROVIDED TO | | | AUTOMATICALLY SHUT DOWN FAN MOTORS. | | | | | | | | | 9) | | | 8.7 ACCESS. | | | 8.7.1 ACCESS TO THE TOPS OF WATER-COOLING TOWERS FOR | | | FIRE FIGHTING AND MAINTENANCE SHALL BE PROVIDED BY AN | | | APPROVED STAIRWAY OR LADDER. | | | | | | 10) | | | WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION | | | CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | | | | 11) | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | PLEASE ENSURE COMPLIANCE, MAKE ANY NECESSARY CHANGES | | | AND PROVIDE AN APPLICABLE NOTE OF COMPLAINCE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-09 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-09 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-27 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-27 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2017-03-27 14:35:52 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. SHT. M2A IS SHOWING A 1.5" MOTORIZED GAS VALVE THE | | | THE GAS INLET FOR THE BOILER IS 2" PER MANUFACTURE THE | | | VALVE S SHOULD BE THE SAME SIZE OR LARGER THAN THE | | | INLET. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 3. THE 12" VENT IS UNDERSIZED SHOULD BE 14" FOR 20' | | | VENT. PER FBC FUEL GAS TABLE 504.2(1) | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-02 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2017-05-09 14:13:33 | 5/9 ON SH DESK PENDING RESPONSE FROM LL | | | | | | | | 2017-05-09 07:48:57 | 5/9 TO CC DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-13 |
Time |
17:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-27 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-16 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-06 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-09 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-09 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-04-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-19 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-19 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2017-04-19 14:00:41 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17020696 | | | 4/19/17 | | | | | | 1) THE REVISED PLANS ARE STILL INDICATING THE EXISTING | | | 14" BOILER FLUE VENT IS STILL UNDERSIZED. PLEASE REFER | | | TO TABLE 504.2 (1) FBC-14 FUEL GAS WHICH INDICATES A | | | 14" FLUE AT 15' HEIGHT AND 5' LATERAL CAN ADEQUATELY | | | VENT UP TO 1,327 MBH BASED ON APPLIANCE INPUT RATING. | | | THIS NUMBER WILL DECREASE USING A 12' FLUE LENGTH AND | | | ALSO USING A 12" CONNECTOR AS INDICATED ON THE PLANS- | | | SEE SECTION 504.2.8 : | | | | | | 504.2.8 VENT AREA AND DIAMETER. | | | WHERE THE VERTICAL VENT HAS A LARGER DIAMETER THAN THE | | | VENT CONNECTOR, THE VERTICAL VENT DIAMETER SHALL BE | | | USED TO DETERMINE THE MINIMUM VENT CAPACITY, AND THE | | | CONNECTOR DIAMETER SHALL BE USED TO DETERMINE THE | | | MAXIMUM VENT CAPACITY. THE FLOW AREA OF THE VERTICAL | | | VENT SHALL NOT EXCEED SEVEN TIMES THE FLOW AREA OF THE | | | LISTED APPLIANCE CATEGORIZED VENT AREA, FLUE COLLAR | | | AREA OR DRAFT HOOD OUTLET AREA UNLESS DESIGNED IN | | | ACCORDANCE WITH APPROVED ENGINEERING METHODS. | | | | | | 2) COMMENTS #5 & 6 FROM THE PREVIOUS REVIEW STILL | | | EXIST. PLEASE REVISE SHEET M-5 TO SHOW THE DETAILS AND | | | DIMENSIONS THAT ARE INDICATED IN THE NARRATIVE REPONSE. | | | PLEASE NOTE THAT THE 8-1/2 X 11" SUBMITTAL DOES NOT | | | PROVIDE: A) ATTACHMENT DETAILS FOR THE COOLING TOWER TO | | | THE STRUCTURE. B) THE CLEARANCE DISTANCE HEIGHT FROM | | | THE ROOF SURFACE. C) DOES NOT BEAR THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL WHO DREW THE PLAN. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-21 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-21 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2017-03-21 13:59:05 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17020696 | | | 3/21/17 | | | | | | 1) SHEET M-1: SHOW THE LOCATION OF EF-11. | | | | | | 2) M-1: INDICATE HOW THE CURB ADAPTERS WILL BE ATTACHED | | | TO THE CURBS, AND INDICATE THE LENGTH OF THE #10 | | | FASTENERS USED TO MOUNT THE FANS. | | | | | | 3) M-2A: INDICATE HOW COMBUSTION AIR IS BEING PROVIDED | | | FOR THE BOILER AND PROVIDE A CALCULATION- SEE SECTION | | | 304 FBC-14 FUEL GAS. | | | | | | 4) M-2A & M5: REFER TO TABLE 504.2.(1): THE 12" BOILER | | | FLUE IS UNDERSIZED FOR THE TOTAL 1435 MBTU INPUT. | | | PLEASE INDICATE THE TOTAL LENGTH OF THE FLUE FROM THE | | | BOILER VENT OUTLET TO THE TERMINATION CAP. A 12" | | | DOUBLE-WALL FLUE AT 20' RUN LENGTH WITH A 0" LATERAL | | | CAN ADEQUATELY VENT GAS-FIRED EQUIPMENT UP TO1350 MBTU | | | INPUT CAPACITY. | | | | | | 5) M-5: AS PREVIOUSLY REQUESTED PROVIDE STRUCTURAL | | | DETAILS FOR ANCHORING THE COOLING TOWER TO THE EXISTING | | | SUPPORT BASE, | | | | | | 6) M-5: REFER TO TABLE 1509.6.5 FBC-14 BUILDING AND | | | INDICATE CLEARANCE HEIGHT BELOW THE COOLING TOWER | | | SUPOPORT BASE TO THE FINISHED ROOF SURFACE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-02-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-21 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2017-02-21 10:12:20 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17020696 | | | 2/21/17 | | | | | | 1) PLEASE ADD THE REPLACEMENT OF THE 14 EXHAUST FANS TO | | | THE WORK DESCRIPTION ON THE APPLICATION, AND ADJUST THE | | | VALUE ACCORDINGLY- SECTION 109.3 WPB AMENDMENTS TO THE | | | FBC. | | | | | | 2) I AM CHALLENGING THE $250,000 JOB VALUE FOR THE | | | PROPOSED PROJECT BASED ON COST VALUATION TABLES | | | PUBLISHED BY MARSHALL & SWIFT VALUATION SERVICE. AS | | | LISTED IN THE TABLES THE THE REPLACEMENT OF THE HEAT | | | PUMPS AND DUCTWORK ALONE WOULD AMOUNT TO APPROXIMATELY | | | $250,000- SEE SECTION 53 PAGE 4. PLEASE PROVIDE AN | | | ITEMIZED COST BREAKDOWN THAT INCLUDES THE COOLING | | | TOWER, THE PUMPS, THE BOILER, THE DUCTWORK, THE PIPING | | | AND CONTROLS, THE EXHAUST FANS, AND THE COOLING TOWER | | | SUPPORT STRUCTURE, STAIRS AND CATWALK. | | | | | | 3) PROVIDE THE WIND LOAD DESIGN CRITERIA FOR | | | INSTALLATION OF ALL THE ROOFTOP FANS AND THE COOLING | | | TOWER, AND ENGINEERED DRAWINGS AND DETAILS FOR | | | INSTALLATION OF THE COOLING TOWER AND SUPPORT | | | STRUCTURE- SECTION 301.15. | | | | | | 4) PROVIDE A LIST OF CODES AND STANDARDS USED IN THE | | | DESIGN OF THE PROJECT. | | | | | | 5) NEW BOILER: A) PROVIDE A COMPLETE EQUIPMENT SCHEDULE | | | FOR THE BOILER INCLUDING BTUH CAPACITY. B) PROVIDE AN | | | ENLARGED DRAWING SHOWING THE REQUIRED WORKING | | | CLEARANCES AND LENGTH OF THE NEW 10'' FLUE. C) PROVIDE | | | THE TOTAL RUN LENGTH OF THE FLUE AND EXISTING VENT FROM | | | THE BOILER OUTLET TO THE TERMINATION ON THE ROOF. D) | | | SHOW THE VENT TERMINATION ON SHEET M-1. | | | | | | 6) COMMISSIONING FOR THE REPLACED COOLING TOWER AND | | | HEAT PUMPS IS REQUIRED PER SECTION C408.2 FBC-14 ENERGY | | | CONSERVATION. PLEASE SUBMIT A COMMISSIONING PLAN AS | | | OUTLINED IN SECTION C408.2.1. | | | | | | 7) PROVIDE A MECHANICAL DEMOLITION PLANS FOR THE | | | EQUIPMENT ROOM. | | | | | | 8) PROVIDE DUCT HANGING AND CONNECTION DETAILS PER | | | SMACNA HVAC CONSTRUCTION STANDARDS 2005. | | | | | | 9) SUBMIT TWO COPIES OF A FL. PRODUCT APPROVAL AND/OR | | | MIAMI-DADE NOA FOR THE GREENHECK LOUVERS. | | | | | | 10) PLEASE CLARIFY IF THE THE REPLACED HEAT PUMPS (O/A | | | UNITS) ARE PART OF THE SMOKE CONTROL SYSTEM AND ARE | | | BEING USED FOR PRESSURIZATION OF CORRIDORS IN THE EVENT | | | OF FIRE. PLEASE NOTE IF THEY ARE SERVING THAT FUNCTION, | | | THEN SPECIAL INSPECTION OF THE SYSTEMS IS REQUIRED AS | | | NOTED IN SECTION 909.3 FBC-14 BUILDING. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-09 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-09 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-04-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-24 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-21 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2017-04-24 09:50:31 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. IN BOTH PLAN SETS THERE ARE TWO M-2A AND M-5 SHTS | | | ONE SHOULD BE MARKED AS VOID OR THE BEST PRACTICE IS TO | | | REMOVE THE OLD SHEET. | | | | | | 2. PROVIDE ON THE PLAN THE BTU LOAD OF EXISTING BOILER. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. SHOW SIZE OF EXISTING GAS LINE. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 4. SHT. M-5 SHOWS RECONNECTION OF EXISTING POTABLE | | | WATER SUPPLY TO TOWER SHOW TYPE OF BACK FLOW IF IT IS A | | | DEVISE AND NOT AN AIR GAP IT SHALL BE CERTIFIED . FBC | | | PL 608.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-27 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-27 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-02 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-02 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2017-03-02 06:59:44 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. M-2 IS THE HEATING BOILER NEW OR EXISTING. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. IF THE BOILER IS BEING REPLACEMENT IS IT SAME FOR | | | SAME , IS THE BTU LOAD ON THE GAS THE SAME. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 3. PLEASE PROVIDE DETAIL FOR POTABLE WATER CONNECTION. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. THE EXISTING BACKFLOW FOR THE POTABLE WATER | | | CONNECTION SHALL BE RECERTIFIED BY A LICENSE CERTIFIED | | | BACKFLOW PREVENTION TESTER. PER CITY OF WPB CROSS | | | CONNECTION CONTROL MANUAL. PROVIDE NOTE ON PLAN. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | A NARRATIVE LISTING THE ORIGINAL REVIEW COMMENT NUMBER | | | WITH A DESCRIPTION OF THE CHANGES MADE AND IDENTIFYING | | | THE SHEET OR SPECIFICATION PAGE WHERE THE CHANGE CAN BE | | | FOUND WILL HELP EXPEDITE THE REVIEW. | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-05-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-05-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-05-09 15:37:27 | * HEIGHT OF THE BUILDING WITH NEW COOLING TOWER IS 126 | | | FT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-04-20 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-04-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-04-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-04-20 12:08:41 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) THE HEIGHT OF THE COOLING TOWER SEEMS TO BE 17 FT. | | | (AT ITS HIGHEST POINT). PLEASE VERIFY THE HEIGHT BY | | | PROVIDING DIMENSIONS TO THE TALLEST POINT OF THE | | | COOLING TOWER. | | | | | | 2.) WHAT IS THE HEIGHT OF THE OTHER EXISTING EQUIPMENT | | | TO BE REPLACED? | | | | | | 3.) PROVIDE ARCHITECTURAL ELEVATIONS SHOWING THE | | | DIMENSIONED HEIGHT OF THE RESIDENTIAL BUILDING. | | | ILLUSTRATIONS SHOWING THE EXISTING BUILDING AND | | | BUILDING WITH THE PROPOSED NEW ROOFTOP EQUIPMENT SHALL | | | BE PROVIDED TO DETERMINE ANY HEIGHT DIFFERENCES, AND | | | CONFORMANCE WITH THE HEIGHT REQUIREMENT OF THE CURRIE | | | MIXED USE DISTRICT (CMUD) TRANSITIONAL SUB-DISTRICT. | | | | | | NOTES: | | | | | | * PROPERTY IS ZONED CMUD (TRANSITION SUB-DISTRICT): | | | HEIGHT LIMITATION IS TEN (10) STORIES/135 FT. | | | | | | * ROOFTOP EQUIPMENT SHALL BE REPLACED AT THE SAME | | | HEIGHT AS THE EXISTING EQUIPMENT OR COMPLY WITH THE | | | HEIGHT REGULATIONS OF THE CMUD TRANSITIONAL | | | SUB-DISTRICT. | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-02-27 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-02-27 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|