 |
Plan Review Details - Permit 17020623
| Plan Review Stops For Permit 17020623 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-27 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-27 |
Time |
06:01 |
Sent To |
|
|
| Notes |
| 2017-06-27 06:30:20 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17020623 CHANGE OF OCCUPANCY!!! | | | ADD: 218 CLEMATIS ST. | | | CONT: MCL CONSTRUCTION INC. | | | TEL: 561-368-2434 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: TUES. JUNE 27/ 2017 | | | ACTION: BUILDING PROVISO | | | | | | | | | 1) BUILDING PROVISO/ DEFERRED SUBMITTAL: 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | CODE105.3.1.2(2) FIRE SPRINKLER DOCUMENTS FOR ANY NEW | | | BUILDING OR ADDITION WHICH INCLUDES A FIRE SPRINKLER | | | SYSTEM WHICH CONTAINS 50 OR MORE SPRINKLER HEADS. A | | | CONTRACTOR I, CONTRACTOR II OR CONTRACTOR IV, CERTIFIED | | | UNDER SECTION 633.521, FLORIDA STATUTES, MAY DESIGN A | | | FIRE SPRINKLER SYSTEM OF 49 OR FEWER HEADS AND MAY | | | DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER | | | SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, | | | ADDITION OR DELETION OF NOT MORE THAN 49 HEADS, NOT | | | WITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER | | | SYSTEM. | | | | | | 2) BUILDING PROVISO/ DEFERRED SUBMITTAL: 2014 FBC-B | | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. 61-41,003 ADMINISTRATION AND | | | DEPARTMENT RESPONSIBILITIES. (4) TESTING & EVALUATION | | | OF PRODUCTS. FL. S. 553.842 PRODUCT EVALUATION AND | | | APPROVAL. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | ROOF TOP VENTILATORS & FANS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 3) BUILDING PROVISO: FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 4) WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS | | | REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & | | | WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN | | | ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF | | | INSPECTION. | | | 2014 FBC-B 2204.1 WELDING | | | 2014 FBC-B 2204.2 BOLTING. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-01 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-01 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-06-01 16:34:07 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17020623 CHANGE OF OCCUPANCY!!! | | | ADD: 218 CLEMATIS ST. | | | CONT: MCL CONSTRUCTION INC. | | | TEL: 561-368-2434 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURS. JUNE 01/ 2017 | | | ACTION: DENIED | | | | | | 1A-B) COMPLIED. | | | | | | 1C) NEW COMMENT WHICH DEALS WITH THE AREA INCREASE | | | TAKEN FOR FIRE SPRINKLERS, NO PLANS WERE SUBMITTED FOR | | | FIRE SPRINKLERS. W. P. B. ADMINISTRATIVE | | | CODE105.3.1.2(2) FIRE SPRINKLER DOCUMENTS FOR ANY NEW | | | BUILDING OR ADDITION WHICH INCLUDES A FIRE SPRINKLER | | | SYSTEM WHICH CONTAINS 50 OR MORE SPRINKLER HEADS. A | | | CONTRACTOR I, CONTRACTOR II OR CONTRACTOR IV, CERTIFIED | | | UNDER SECTION 633.521, FLORIDA STATUTES, MAY DESIGN A | | | FIRE SPRINKLER SYSTEM OF 49 OR FEWER HEADS AND MAY | | | DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER | | | SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, | | | ADDITION OR DELETION OF NOT MORE THAN 49 HEADS, NOT | | | WITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER | | | SYSTEM. | | | | | | 2) 2ND REQUEST. PLEASE NOTE THE ENERGY FORMS STATE | | | RIGHT BY THE SIGNATURE, THIS SIGNATURE IS AN ELECTRONIC | | | SIGNATURE. THE SUBMITTED ENERGY CALS. AND HVAC CALS. | | | ARE PRINTED BUT HAVE A DIGITAL SIGNATURE, BY JOHN | | | LANGFORD P. E. PLEASE SHOW COMPLIANCE WITH FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEES SIGNATURE SHALL NOT BE USED ON ELECTRONICALLY | | | SIGNED AND SEALED ENGINEERING PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS. | | | | | | 3) SHEET A0.3 SHOWS 127 INTERIOR SEATS, 26 EXTERIOR | | | SEATS AND WHAT MAY APPEAR TO BE 30 FEET OF STANDING AT | | | THE BAR, UNDETERMINABLE AMOUNT OF FOOTAGE AND USE? | | | | | | 3A-C) COMPLIED | | | | | | 3D) PLEASE NOTE THE FIRE PLAN REVIEWERS NOTES ON THE | | | FIRE PIT. THE PLANS SHOW IN THE CENTER OF THE PLAN A | | | INDOOR FIRE PIT, PLEASE PROVIDE THE TYPE OF FUEL, | | | AMOUNT OF FUEL AND THE AMOUNT OF BTU?S WILL BE USED PER | | | HOUR. 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4-6) COMPLIED. | | | | | | 7A) SEMI-COMPLIED. IT IS TRUE THE FRONT ENTRY DOOR DOES | | | NOT REQUIRE PANIC HARDWARE BUT THE HARDWARE DOES NEED | | | TO COMPLY WITH : 2014 FBC-B SECTION 1008.1.9.3(2) | | | 2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT | | | LOAD OF 300 OR LESS, GROUPS B, F, M AND S, AND IN | | | PLACES OF RELIGIOUS WORSHIP, THE MAIN EXTERIOR DOOR OR | | | DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED | | | LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: | | | | | | 2.1. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS | | | LOCKED; | | | | | | 2.2. A READILY VISIBLE DURABLE SIGN IS POSTED ON THE | | | EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS | | | DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE | | | SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A | | | CONTRASTING BACKGROUND; AND | | | | | | 2.3. THE USE OF THE KEY-OPERATED LOCKING DEVICE IS | | | REVOKABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. | | | | | | 7B) THE REAR EXIT DOOR NOT LABELED ON SHEET A0.5 AND | | | NOT INCLUDED IN THE DOOR SCHEDULE SHEET A7.1 DOES | | | INDICATE A DOOR 108 TO BE VERIFIED PANIC HARDWARE IS | | | REQUIRED. PLEASE IDENTIFY THE DOOR ON SHEET A0.5. | | | | | | 8) COMPLIED. | | | | | | 8A) NEW COMMENT DEALS WITH A0.5 THE AWNING OVER THE | | | PUBLIC SIDEWALK AND HOW CLOSE THE CURB IS TO THE | | | AWNING. THE CURB IS NOT SHOWN IN THE DEPICTED PLAN. | | | COMPLIANCE WITH 2014 FBC-B SECTION 3202.3.1 CANNOT BE | | | DETERMINED. | | | 3202.3.1 AWNINGS, CANOPIES, MARQUEES AND SIGNS. | | | AWNINGS, CANOPIES, MARQUEES AND SIGNS SHALL BE | | | CONSTRUCTED SO AS TO SUPPORT APPLICABLE LOADS AS | | | SPECIFIED IN CHAPTER 16. AWNINGS, CANOPIES, MARQUEES | | | AND SIGNS WITH LESS THAN 15 FEET (4572 MM) CLEARANCE | | | ABOVE THE SIDEWALK SHALL NOT EXTEND INTO OR OCCUPY MORE | | | THAN TWO-THIRDS THE WIDTH OF THE SIDEWALK MEASURED FROM | | | THE BUILDING. STANCHIONS OR COLUMNS THAT SUPPORT | | | AWNINGS, CANOPIES, MARQUEES AND SIGNS SHALL BE LOCATED | | | NOT LESS THAN 2 FEET (610 MM) IN FROM THE CURB LINE. | | | | | | | | | 9) BUILDING PROVISO: 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. 61-41,003 | | | ADMINISTRATION AND DEPARTMENT RESPONSIBILITIES. (4) | | | TESTING & EVALUATION OF PRODUCTS. FL. S. 553.842 | | | PRODUCT EVALUATION AND APPROVAL. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | ROOF TOP VENTILATORS & FANS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 10) BUILDING PROVISO: FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 11) SEMI-COMPLIED. THE ROOF TOP EXHAUST FAN DOES HAVE A | | | DETAIL FOR ANCHORING OF THE FAN TO THE CURB AND CURB TO | | | THE ROOF FRAMING. THE MECHANICAL REVIEWER REQUEST | | | DETAILS AS WELL FOR THE NEW ROOF TOP CONDENSERS TO THE | | | EXISTING STANDS. | | | ROOF TOP A/C STANDS WILL NEED TO SUPPLY THE FOLLOWING | | | INFORMATION, CALCULATE THE AREA OF THE ROOF TOP | | | COMPRESSORS, THE MEAN ROOF HEIGHT OF THE STAND AND | | | COMPRESSORS, WEIGHT, CIRCLED THE DESIGN PARAMETERS IN | | | THE TABLES , ANCHORS AND UPLIFT VERSES MOMENT. 2014 | | | FBC-B 1604.4 ANALYSIS. | | | | | | 12) WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS | | | REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & | | | WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN | | | ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF | | | INSPECTION. | | | 2014 FBC-B 2204.1 WELDING | | | 2014 FBC-B 2204.2 BOLTING. | | | | | | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-17 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2017-03-17 13:47:10 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17020623 CHANGE OF OCCUPANCY!!! | | | ADD: 218 CLEMATIS ST. | | | CONT: MCL CONSTRUCTION INC. | | | TEL: 561-368-2434 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. MARCH 17/ 2017 | | | ACTION: DENIED | | | | | | 1A) THE COVERSHEET LIST THE FLOOR RATING AS A1.0 HOUR | | | FIRE RATING PER TABLE 601 OF THE 2014 FBC-B. THE | | | COVERSHEET DOES NOT LIST ANY CRITERIA FOR HORIZONTAL | | | ASSEMBLIES OR OCCUPANCY SEPARATION FOR HORIZONTAL | | | ASSEMBLIES SEPARATING THE A2 ASSEMBLY USE AND THE | | | BUSINESS OCCUPANCY ON THE 2ND FLOOR. PLEASE REVIEW | | | TABLE 707.310 OF THE FBC-B THE REQUIREMENT FOR 2 HOUR | | | FIRE SEPARATION BETWEEN THE HORIZONTAL ASSEMBLIES | | | BETWEEN FIRE AREAS. THIS IS A MIXED USE BUILDING PLEASE | | | PROVIDE THE TOTAL SQ. FT. FOR EACH OCCUPANCY PER FLOOR | | | AND 508.4.2 ALLOWABLE BUILDING AREA. IN EACH STORY, THE | | | BUILDING AREA SHALL BE SUCH THAT THE SUM OF THE RATIOS | | | OF THE ACTUAL BUILDING AREA OF EACH SEPARATED OCCUPANCY | | | DIVIDED BY THE ALLOWABLE BUILDING AREA OF EACH | | | SEPARATED OCCUPANCY SHALL NOT EXCEED 1. | | | | | | 1B) IN THE EXISTING BUILDING CODE SECTION 1012.5.1 FIRE | | | WALL ALTERNATIVE FOR HORIZONTAL ASSEMBLIES THERE ARE | | | (3) REQUIREMENTS IF ALL (3) REQUIREMENTS ARE MET THAN | | | THE HORIZONTAL ASSEMBLIES CAN BE REDUCED TO (1) HOUR. | | | PLEASE NOTE THIS TENANT SPACE IS ONLY (1) TENANT SPACE | | | OF THE BUILDING ADDRESSED 230 CLEMATIS WITH 18,317 | | | SQUARE FEET ON THE 1ST FLOOR AND 14,344 ON THE SECOND | | | FLOOR. | | | | | | 2) THE SUBMITTED ENERGY CALS. AND HVAC CALS. ARE | | | PRINTED BUT HAVE A DIGITAL SIGNATURE, BY JOHN LANGFORD | | | P. E. PLEASE SHOW COMPLIANCE WITH FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | 3) SHEET A0.3 SHOWS 127 INTERIOR SEATS, 26 EXTERIOR | | | SEATS AND WHAT MAY APPEAR TO BE 30 FEET OF STANDING AT | | | THE BAR, UNDETERMINABLE AMOUNT OF FOOTAGE AND USE? | | | | | | 3A) PLANS SHOW 8 ACCESSIBLE SEATING AREAS. THE UNKNOWN | | | IS THE USAGE OF THE 30 FEET OF BAR APPEARS TO BE | | | STANDING ROOM? COMPLIANCE WITH FBC-ACCESS. CODE 226.1. | | | WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION | | | OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING | | | SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL | | | COMPLY WITH 902. | | | | | | 3B) SEMI-COMPLIED. THE UNKNOWN IS THE USAGE OF THE 30 | | | FEET OF BAR APPEARS TO BE STANDING ROOM? | | | PLEASE SHOW COMPLIANCE WITH THE 2014 FBC-ACCESS. CODE | | | 226.2 DISPERSION. DINING SURFACES REQUIRED TO COMPLY | | | WITH 902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR | | | FACILITY. | | | | | | 3C) PLEASE SHOW COMPLIANCE WITH THE 2014 FBC-ACCESS. | | | CODE 902.1. DINING SURFACES AND WORK SURFACES SHALL | | | COMPLY WITH 902.2 AND 902.3. | | | 3C)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 3C)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3D) THE PLANS SHOW IN THE CENTER OF THE PLAN A INDOOR | | | FIRE PIT, PLEASE PROVIDE THE TYPE OF FUEL, AMOUNT OF | | | FUEL AND THE AMOUNT OF BTU?S WILL BE USED PER HOUR. | | | 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4)SHEET A0.6 THE DETAIL MOUNTING HEIGHTS SHOWS SIGNAGE | | | LOCATED CENTER LINED AT 60 INCHES. PLEASE SHOW | | | COMPLIANCE WITH ACCESS. CODE 703.4.1 HEIGHT ABOVE | | | FINISH FLOOR OR GROUND. TACTILE CHARACTERS ON SIGNS | | | SHALL BE LOCATED 48 INCHES (1220 MM) MINIMUM ABOVE THE | | | FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES | | | (1525 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND | | | SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST | | | TACTILE CHARACTER. | | | | | | 5) SHEET A0.6 THE RESTROOM DETAILS FOR THE WATER CLOSET | | | GRAB BARS SHOWS THE DIMENSION TAKEN FROM THE FLOOR TO | | | CENTERLINE OF THE GRAB BAR, BE AWARE THE 2014 ACCESS. | | | CODE CHANGED THE DIMENSION TO THE TOP OF THE GRASPING | | | SURFACE, SEE ACCESS. CODE 609.4. | | | | | | 6) DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. PLEASE REVIEW SHEET A0.7 AND | | | M2.1. SHEET A0.7 INDICATES A (1) HOUR FIRE RATING | | | WHEREAS THE M2.1 SHOWS A (2) HR. FIRE RATING. SHAFTS | | | LESS THAN 4 STORIES ONLY REQUIRE A 1 HOUR FIRE RATING, | | | FBC-B 713.4. | | | | | | 7) SEE SHEETS A0.5 FLOOR PLAN ENTRY DOOR 101 AND SHEET | | | A8.3 DETAILS 5&6. SHEET A0.5 SHOWS A SINGLE ENTRY DOOR | | | AND SIDE LIGHT. SHEET A8.3 SHOWS 2 DETAILS OF THE ENTRY | | | DOOR, THE SIDE LIGHT DOESN?T APPEAR IN ANY DETAILS. THE | | | OTHER ISSUE IS IN DETAIL 5 IT IS A SINGLE PAIN OF GLASS | | | WITH PANIC HARDWARE, IN DETAIL # 6 THERE ARE (2) PANES | | | OF GLASS AND NO PANIC HARDWARE. 107.2.1.3 DISCREPANCY | | | IN PLANS AND FBC-B 1008.1.10 PANIC AND FIRE EXIT | | | HARDWARE. | | | | | | 8) SHEET A8.5 DETAIL # 11 SHOWS A PATIO GATE AND DETAIL | | | # 5 A GUARDRAIL. SHEETS A0.3 AND A0.5 BOTH SHOW THE | | | OUTDOOR PATIO BUT PLEASE NOTE THIS AREA IS THE PUBLIC | | | RIGHT OF WAY. FBC-B 3202.1.3 AREAWAYS. | | | AREAWAYS SHALL BE PROTECTED BY GRATES, GUARDS OR OTHER | | | APPROVED MEANS. | | | | | | 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN | | | HEIGHT. | | | ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY ABOVE GRADE | | | AND BELOW 8 FEET (2438 MM) IN HEIGHT SHALL BE | | | PROHIBITED EXCEPT AS PROVIDED FOR IN SECTIONS 3202.2.1 | | | THROUGH 3202.2.3. DOORS AND WINDOWS SHALL NOT OPEN OR | | | PROJECT INTO THE PUBLIC RIGHT-OF-WAY. | | | 3202.2.1 STEPS. | | | 3202.2.2 ARCHITECTURAL FEATURES. | | | 3202.2.3 AWNINGS. | | | | | | 9) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. 61-41,003 | | | ADMINISTRATION AND DEPARTMENT RESPONSIBILITIES. (4) | | | TESTING & EVALUATION OF PRODUCTS. FL. S. 553.842 | | | PRODUCT EVALUATION AND APPROVAL. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE | | | CODE 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | ROOF TOP VENTILATORS & FANS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | 10) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 11) SHEET M103 SHOWS ROOF TOP FANS BUT THE DETAILS DO | | | NOT PROVIDE ANCHORAGE OF THE CURB TO THE ROOF FRAMING | | | NOR THE ROOFTOP FAN TO THE UNIT. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | 2014 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES DETERMINED IN ACCORDANCE WITH THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-12 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-12 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-03-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-03-10 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-03-09 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2017-03-10 10:50:30 | PAGE E101 | | | A) LOAD CACLUATION PER ARTICLE 220 REQUIRED. | | | B) FAULT CURRENT CALCULATION REQUIRED PER 110.24 | | | C) LABELING FOR FAULT CURRENT REQUIRED PER 100.24 | | | D) NEED THE GROUNDING DETAIL SHOWN ON DRAWING FOR THE | | | SERVICE. | | | E) RISER DIAGRAM FEEDER 200 TOO SMALL FOR 400A | | | F) RISER DIAGRAM FEEDER 300 NOT SHOWN ON DRAWINGS | | | G) TIME CLOCK SUBMIT CUT SHEET | | | | | | PAGE E201 | | | A) CIRCUITS AT THE BAR B19,21,23, A48,18,22 REQUIRE | | | GFCI PROTECTION 210.8(B)(5) | | | B) KITCHEN OUTLETS A29,34,53,58,59, B31,33,35,37 | | | REQUIRE GFCI PROTECTION 210.8(B)(2) | | | | | | PAGE E202 | | | A) ROOF NEEDS AN OUTLET WITHIN 25' OF THE EQUIPMENT AND | | | GFCI PROTECTED 210.63, 210.8(B)(3) | | | | | | PAGE E301 | | | A) SUBMIT INTERIOR LIGHTING POWER ALLOWANCES PER FBC EC | | | C405.5.2 | | | B) LIGHTING IN BAR AREA NOT CLEAR ON DRAWINGSS LINES | | | ALL OVER THE AREA NOT CONNECTED TO ANYTHING. | | | C) LIGHT FIXTURE TYPES TO BE LABLELED ON ALL FIXTURES | | | ON DRAWING FOR REVIEW. | | | D) ALL CIRCUITS ARE SHOWN AS TIME CLOCK NEED CIRCUIT | | | NUMBERS ON PLANS FOR LIGHTING. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-06-28 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-06-28 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-05-31 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-05-24 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2017-05-24 12:15:28 | 218 CLEMATIS STREET | | | PERMIT #17020623 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PRODUCT DATA FOR THE FIRE PIT INDICATES IT IS ONLY | | | TO BE INSTALLED OUTDOORS. ADDITIONALLY THIS OFFICE DOES | | | NOT SUPPORT THE USE OF INTERIOR OPEN FLLAME DEVICES. | | | | | | SHEET E301: NO EMERGENCY LIGHTING PROVIDED. | | | | | | NFPA 96 SECTION 14.1.5 WHERE A SOLID FUEL COOKING | | | APPLIANCE ALLOWS EFFLUENT TO ESCAPE FROM THE APPLIANCE | | | OPENING, THIS OPENING SHALL BE COVERED BY A HOOD AND AN | | | EXHAUST SYSTEM THAT MEETS THE REQUIREMENTS OF SECTIONS | | | 14.3, 14.4, AND 14.6.14.7.1 SOLID FUEL COOKING | | | APPLIANCES THAT PRODUCE GREASELADEN VAPORS SHALL BE | | | PROTECTED BY LISTED FIRE-EXTINGUISHING EQUIPMENT. NO | | | TYPE I EXHAUST HOOD WITH SUPPRESSION SYSTEM PROVIDED | | | FOR WOOD FIRED PIZZA OVENS. | | | | | | SOLID COOKING OPERATIONS AND DESIGN SHALL COMPLY WITH | | | NFPA 96. APPLIANCES WITH FIREBOXES OVER 5 FT3 THE WATER | | | SOURCE SHALL BE A FIXED PIPE WATER SYSTEM WITH A HOSE | | | OF ADEQUATE LENGTH TO REACH THE COMBUSTION AND COOKING | | | CHAMBERS OF THE APPLIANCE. ALL OVEN ASH SHALL BE | | | REMOVED FROM THE ASH COMPARTMENT AT LEAST ONCE PER DAY. | | | THE ASH SHALL BE SPRAYED ADEQUATELY WITH WATER BEFORE | | | REMOVAL TO EXTINGUISH ANY HOT ASH OR CINDERS AND TO | | | CONTROL THE DUST WHEN THE ASH IS MOVED. SECTION | | | 14.9.3.8.1 A HEAVY METAL CONTAINER OR CART (MINIMUM 16 | | | GAUGE) WITH A COVER SHALL BE PROVIDED FOR THE REMOVAL | | | OF ASH. THE ASH REMOVAL CONTAINER OR CART SHALL NOT | | | EXCEED A MAXIMUM OF 20 GAL CAPACITY, SHALL BE ASSIGNED | | | FOR THIS ONE PURPOSE, SHALL BE ABLE TO BE HANDLED | | | EASILY BY ANY EMPLOYEE ASSIGNED THE TASK, AND SHALL | | | PASS EASILY THROUGH ANY PASSAGEWAY TO THE OUTSIDE OF | | | THE BUILDING. THE CONTAINER OR CART SHALL ALWAYS BE | | | COVERED WHEN IT IS BEING MOVED THROUGH THE PREMISES. | | | | | | NO FIRE ALARM OR FIRE SPRINKLER SCOPE OF WORK PROVIDED. | | | | | | EXISTING EXIT DOORS: FOR ASSEMBLY OCCUPANCIES WITH AN | | | OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER | | | THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE | | | PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER | | | LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE | | | RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR | | | PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE | | | AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A | | | READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN | | | UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS | | | SHALL BE AT LEAST 1 INCH IN HEIGHT. KEYED LOCK TO BE | | | EQUIPPED WITH AN ?OPEN/LOCKED? INDICATOR WINDOW (SUCH | | | AS ADAMS RITE 4089 OR SIMILAR). A THUMB TURN STYLE LOCK | | | IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED LOCK. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-03-01 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-03-01 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-02-21 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2017-03-01 11:25:59 | 218 CLEMATIS STREET | | | PERMIT #17020623 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | | OF NFPA 241. | | | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | | BE APPROVED AND SUBMITTED IN WRITING TO THE OFFICE OF | | | THE FIRE MARSHAL. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | PROVIDE TACTILE SIGNAGE AT EXIT DOORS. | | | | | | INSUFFICIENT EXIT SIGNS PROVIDED TO IDENTIFY PRIMARY | | | AND SECONDARY EXITS. NO EMERGENCY LIGHTING PROVIDED. | | | | | | PROVIDE MORE INFORMATION AND DETAILS FOR THE FIREPIT. | | | SUBMIT PRODUCT DATA AND UL LISTING (OR EQUAL). | | | | | | PROVIDE UL LISTING (OR EQUAL) DATA FOR THE PIZZA OVENS. | | | SUBMIT PRODUCT DATA FOR WOOD FIRED PIZZA OVENS | | | INDICATING IF A SUPPRESSION SYSTEM IS REQUIRED FOR THIS | | | APPLIANCE. | | | | | | INDICATE THE LOCATION AND QUANTITY OF WOOD FUEL TO BE | | | STORED FOR THE PIZZA OVENS. | | | | | | SOLID COOKING OPERATIONS AND DESIGN SHALL COMPLY WITH | | | NFPA 96. FOR EXAMPLE: PER SECTION 14.9.2.1. FUEL | | | STORAGE SHALL NOT EXCEED A ONE-DAY SUPPLY WHERE STORAGE | | | IS LOCATED IN THE SAME ROOM AS THE SOLID FUELED | | | APPLIANCE, OR IN THE SAME ROOMS AS THE FUEL-LOADING OR | | | CLEAN-OUT DOORS. SECTION14.9.3.7.3 APPLIANCES WITH | | | FIREBOXES OVER 5 FT3 THE WATER SOURCE SHALL BE A FIXED | | | PIPE WATER SYSTEM WITH A HOSE OF ADEQUATE LENGTH TO | | | REACH THE COMBUSTION AND COOKING CHAMBERS OF THE | | | APPLIANCE. ALL OVEN ASH SHALL BE REMOVED FROM THE ASH | | | COMPARTMENT AT LEAST ONCE PER DAY. THE ASH SHALL BE | | | SPRAYED ADEQUATELY WITH WATER BEFORE REMOVAL TO | | | EXTINGUISH ANY HOT ASH OR CINDERS AND TO CONTROL THE | | | DUST WHEN THE ASH IS MOVED. SECTION 14.9.3.8.1 A HEAVY | | | METAL CONTAINER OR CART (MINIMUM 16 GAUGE) WITH A COVER | | | SHALL BE PROVIDED FOR THE REMOVAL OF ASH. THE ASH | | | REMOVAL CONTAINER OR CART SHALL NOT EXCEED A MAXIMUM OF | | | 20 GAL CAPACITY, SHALL BE ASSIGNED FOR THIS ONE | | | PURPOSE, SHALL BE ABLE TO BE HANDLED EASILY BY ANY | | | EMPLOYEE ASSIGNED THE TASK, AND SHALL PASS EASILY | | | THROUGH ANY PASSAGEWAY TO THE OUTSIDE OF THE BUILDING. | | | THE CONTAINER OR CART SHALL ALWAYS BE COVERED WHEN IT | | | IS BEING MOVED THROUGH THE PREMISES. | | | | | | MEP PLANS ARE SIGNED; HOWEVER, THE SEAL IS A COPY OF | | | THE SEAL. | | | | | | NO FIRE ALARM OR FIRE SPRINKLER SCOPE OF WORK PROVIDED. | | | | | | WESLEY JOLIN | | | WEST PALM BEACH FIRE RESCUE | | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-09 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2017-06-09 15:02:19 | 6/9/17 THE GAS HAS BEEN REMOVED FROM PLANS/GPJ |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-17 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-17 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2017-03-17 09:22:30 | GAS COMMENTS: | | | | | | 1. SHOW COMPLIANCE WITH FBC FUEL GAS 404.8.2 CONDUIT | | | WITH BOTH ENDS TERMINATING INDOORS. | | | WHERE THE CONDUIT ORIGINATES AND TERMINATES WITHIN THE | | | SAME BUILDING, THE CONDUIT SHALL ORIGINATE AND | | | TERMINATE IN AN ACCESSIBLE PORTION OF THE BUILDING AND | | | SHALL NOT BE SEALED. THE CONDUIT SHALL EXTEND NOT LESS | | | THAN 2 INCHES (51 MM) BEYOND THE POINT WHERE THE PIPE | | | EMERGES FROM THE FLOOR. | | | | | | 2, SHOW ROUTING FROM METER TO STEP DOWN REGULATOR NOT | | | SHOWN ON SITE PLAN. PER WPB AMEND TO FBC 107,2,1 | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 6. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-06-29 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-16 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-06-15 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-05-17 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-02-14 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-06 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-07-03 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2017-07-06 10:07:17 | PALM BEACH COUNTY IMPACT FEE OFFICE | | | MU-2017-018590-0000 | | | RECEIPT NUMBER: 2017-0705-47 | | | FEES: $244.64 | | 2017-07-03 15:54:41 | GIVEN TO JWITMER |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-27 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-27 |
Time |
06:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-01 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-01 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-06-01 16:34:56 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-03-17 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-03-14 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2017-03-17 10:54:29 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-29 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-28 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-31 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-31 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2017-05-31 14:41:38 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17020623 | | | 5/31/17 | | | | | | RESULTS: DENIED. | | | | | | 1) THE TWO GREASE EXHAUST DUCTS FOR THE PIZZA OVENS | | | MUST BE RUN SEPARATELY BECAUSE THEY ARE SERVING | | | SOLID-FUEL FIRED APPLIANCES- PLEASE SEE SECTION 506.3.5 | | | ITEM #4 AND SEPARATE THE DUCTS. | | | | | | 2) ADVISORY: PLEASE REVIEW PAGE #3 OF THE SUBMITTED | | | INSTALLATION INSTRUCTIONS FOR THE PIZZA OVENS AND | | | SPECIFY ON THE PLANS WHICH OF THE THREE EXHAUST SYSTEMS | | | WILL BE INSTALLED. | | | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | VENTLESS RANGE AND DISHWASHER HOODS AND PROVIDE | | | EQUIPMENT SCHEDULES ON THE PLANS. | | | | | | 4) THE CAPTIVE-AIRE KITCHEN EXHAUST PLANS (SHEETS M102 | | | & M103) ARE NO LONGER APPLICABLE TO THE PROJECT. PLEASE | | | EITHER REMOVE THE SHEETS FROM THE PLAN SETS, OR REVISE | | | THEM TO SHOW THE NEW VENTLESS HOODS PLANS, DETAILS, AND | | | EQUIPMENT SCHEDULES. | | | | | | 5) M101: THE AIR BALANCE DIAGRAM NEEDS TO BE REVISED TO | | | MATCH THE REVISED PLANS AND SYSTEMS. PLEASE NOTE THE | | | FOLLOWING: A) EF02 IS INDICATED TO HAVE A CAPACITY OF | | | 1475 CFMS IN THE AIR BALANCE DIGRARM, BUT ONLY 470 CFMS | | | IN THE FAN SCHEDULE. B) EF04 AND SF03 ARE STILL SHOWING | | | IN THE DIAGRAM HOWEVER THEY HAVE BEEN REMOVED FROM THE | | | PLANS. | | | | | | 6) M101: PLEASE PLACE A NOTE TO INDICATE THE LOCATIONS | | | OF THE AHU ACCESS PANELS AND PROVIDE DIMENSIONS- | | | SECTION 306.1 | | | | | | 7) THE WIND LOAD ENGINEERING FOR INSTALLATION OF THE | | | ROOFTOP EQUIPMENT IS INCOMPLETE: A) PROVIDE DETAILS FOR | | | ANCHORING THE NEW CONDENSERS TO THE EXISTING STANDS. B) | | | PROVIDE DETAILS FOR INSTALLATION OF THE GREASE DUCT | | | SUPPORTS. C) SUBMIT THE NOA FOR THE NEW ROOF STAND WITH | | | SHOP DRAWING APPORVAL STAMP BY THE EOR. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-02-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-23 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-23 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2017-02-23 13:01:05 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17020623 | | | 2/23/17 | | | | | | 1) THE CITY OF WEST PALM BEACH BUILDING DIVISION | | | REQUIRES SEPARATE PERMITS FOR KITCHEN EXHAUST HOODS, | | | FIRE SUPPRESSION SYSTEMS, FIRE SPRINKLERS, AND WALK-IN | | | COOLERS AND FREEZERS- PLACE A NOTE ON THE PLANS | | | ACCORDINGLY. PLEASE NOTE THAT NO DETAILS OR | | | SPECIFICATIONS FOR THE DISHWASHER HOOD HAVE BEEN | | | PROVIDED. | | | | | | 2) SHEET M201: THE MAKEUP AIR DUCT FOR THE KITCHEN | | | HOODS IS PROHIBITED FROM BEING IN THE SAME RATED SHAFT | | | ENCLOSURE WITH THE GREASE EXHAUST DUCT- SECTION | | | 506.3.11. OPTIONS- REMOVE THE MAKEUP AIR DUCT, OR | | | INDICATE THE GREASE DUCT IS TO BE WRAPPED WITH APPROVED | | | LISTED AND LABELED DUCT WRAP PER SECTION 506.3.11.2. | | | | | | 3) ADVISORIES- KITCHEN AND EXHAUST HOODS: | | | | | | A) AN 18" CLEARANCE TO COMBUSTIBLES IS REQUIRED FOR THE | | | GREASE EXHAUST DUCTS- SEE SECTIONS 506.3.6, 506.3.11, | | | 506.3.11.1, & 506.3.11.2. IF A DUCT WRAP IS TO BE | | | INSTALLED, MANUFACTURER'S SPECIFICATIONS SHALL BE | | | SUBMITTED PER SECTION 506.3.11.2, AND THE GREASE DUCT | | | PENETRATIONS INTO AND OUT OF THE RATED SHAFTS SHALL BE | | | PROTECTED WITH A THROUGH-PENETRATION FIRE-STOP SYSTEM | | | CLASSIFIED IN ACCORDANCE WITH ASTM E 814 OR UL 1497. | | | PLEASE NOTE THAT THERE IS NO REQUIREMENT FOR THE FIRE | | | DAMPERS TO BE INSTALLED IN THE GREASE DUCTS AT THE | | | SHAFT PENETRATIONS. | | | | | | B) PLEASE NOTE THAT THE TEMPERATURE DIFFERENTIAL | | | BETWEEN MAKE-UP AIR FOR THE KITCHEN EXHAUST AND THE AIR | | | IN THE CONDITIONED SPACE SHALL NOT EXCEED 10 DEGREES F | | | PER SECTION 508.1.1. MEETING THIS COMPLIANCE MAY | | | REQUIRE PRE-COOLING OF THE MAKE-UP AIR USING AN AC UNIT | | | | | | C) THE NOA'S FOR THE ROOFTOP FANS MUST BE SUBMITTED | | | WITH SHOP DRAWING APPROVAL STAMPS AND SIGNATURES BY THE | | | ENGIEER OF RECORD. THE EOR MUST ALSO CIRCLE, HIGHLIGHT, | | | OR OTHERWISE MARK ALL APPLICABLE INSTALLATION NOTES, | | | DETAILS, DESIGN PRESSURES, AND ANCHORING METHODS ON THE | | | DOCUMENTS. | | | | | | 4) SHEETS M201 & A0.7: THE PLANS ARE CONFLICTING | | | CONCERNING THE HOURLY FIRE-RATINGS OF THE SHAFTS. | | | | | | 5) SHEET M201: INDICATE THE REQUIRED CLEARANCE DISTANCE | | | MEASUREMENTS FOR THE O/A INTAKE LOCATIONS AS REQUIRED | | | BY SECTION 401.4. | | | | | | 6) M201: SHOW THE TERMINATION LOCATION OF THE | | | DISHWASHER HOOD EXHAUST DUCT. | | | | | | 7) M201: REFER TO SECTION 304 FLORIDA FUEL GAS CODE AND | | | PROVIDE COMBUSTION AIR CALCULATIONS FOR THE PIZZA | | | OVENS, THE KITCHEN COOKING APPLIANCES, AND THE GAS | | | WATER HEATER. | | | | | | 8) PROVIDE AN EQUIPMENT SCHEDULE FOR THE GAS WATER | | | HEATER AND MODIFY THE DETAIL ON M101 TO INDICATE THE | | | TYPE AND SIZE OF GAS VENT AND TOTAL RUN FROM THE WH TO | | | THE TERMINATION CAP. | | | | | | 9) M201: INDICATE HOW ACCESS FOR MAINTENANCE AND | | | REPLACEMENT OF THE AIR HANDLERS IN THE SOFFIT WILL BE | | | PROVIDED- SEE SECTION 306.1. | | | | | | 10) M201: PROVIDE CONDENSATE DISPOSAL PLANS FOR THE | | | AHU'S- SECTION 307. | | | | | | 11) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE PIZZA | | | OVENS AND THEIR ASSOCIATED EXHAUST HOODS AND VENTS. SEE | | | COMMENT #2B ABOVE- FIRE DAMPERS MAY NOT BE REQUIRED FOR | | | THE EXHAUST DUCT PENETRATING THE SHAFT ENCLOSURE. | | | | | | 12) WIND LOAD ENGINEERING IS REQUIRED FOR INSTALLATION | | | OF ALL THE ROOF TOP MECHANICAL EQUIPMENT PER SECTION | | | 301.15. PLEASE PROVIDE COMPLETE DETAILS FOR ANCHORING | | | THE UNITS TO THE ROOF STRUCTURE. | | | | | | 13) PLEASE REVIEW CHAPTER 10 OF THE FBC-14 EXISTING | | | BUILDING CODE- THE PROPOSED PROJECT IS A CHANGE OF | | | OCCUPANCY AND SHOULD BE NOTED AS SUCH UNDER THE | | | BUILDING CODE DATA ON SHEET A0.1. | | | | | | 14) PLEASE REVIEW SECTION C101.4.4 AND SECTION C401.2 | | | FBC-14 ENERGY CONSERVATION AND PROVIDE DOCUMENTATION OF | | | ENERGY CONSERVATION COMPLIANCE. THE SUBMITTED ENERGY | | | FORM C402-2014 IS FOR RENOVATED BUILDINGS, AND CANNOT | | | BE USED FOR BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-09 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-09 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-17 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-17 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2017-03-17 09:12:43 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. DOOR ON ACCESSIBLE TOILET STALLS SHALLL NOT SWING | | | INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR | | | ANY FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE | | | REQUIRED TURNING SPACE. PER FBC ACC 603.2.3 | | | | | | 2. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL | | | POSITION, 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 | | | MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP | | | OF THE GRIPPING SURFACE, PER FBC ACC 609.4 | | | | | | 3. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL | | | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES | | | NOT ALLOW CONTINUOUS PAPER FLOW. PER FBC ACC 604.7 | | | | | | 4. DRINKING FOUNTAINS SHALL COMPLY WITH 307 AND 602. | | | PER FBC ACC 602.1 | | | | | | 5. ALL FIXTURE FLOWING THROUGH GREASE INTERCEPTOR SHALL | | | BE INCLUDED ON THE SIZING CALCULATION THE FIXTURES THAT | | | ARE MISSING FROM CALCULATIONS ARE # 4 MOP SINK, #6.1 | | | SINK, #6.2 SINK, #7 PRE RINSE SINK, #8 DISHWASHER , #12 | | | SINK , #32.A TROUGH DRAIN. PER FBC PL 1003.3.1 | | | | | | 6. FIXTURES IN THE BAR AREA SHALL NOT BE ON THE GREASE | | | SYSTEM. PER FBC PL 1003.2 | | | | | | 7. THE THREE COMP SINK SHALL BE INDIRECTLY WASTED. PER | | | FBC PL 802.1 | | | | | | 8. SHT. P101 DETAIL B5 THE FIRST NOTE REQUIRING | | | TEMPERED WATER IS WRONG THE TEMPERATURE FOR TEMPERED | | | WATER SHAL BE BETWEEN 85?F (29?C) AND 110?F (43?C). PER | | | FBC PL 202 | | | | | | 9. SHOW TEMPERATURE LIMITING DEVICE ON WATER RISER | | | DIAGRAM TO SHOW COMPLIANCE WITH FBC PL 416.5 | | | | | | 10. SHOW COMPLIANCE WITH FBC PL 604.9 WATER HAMMER. | | | THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM | | | SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED | | | WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER | | | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER?S INSTRUCTIONS. WATER-HAMMER ARRESTORS | | | SHALL CONFORM TO ASSE 1010. | | | | | | | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-06-29 |
Time |
15:34 |
Sent To |
I |
|
| Notes |
| 2017-06-29 15:35:02 | BASED ON WASTE PRODUCTION CALCULATIONS, THE BUILDING | | | OWNER WILL BE CONTACTED FOR NECESSARY IMPROVEMENTS TO | | | THE WASTE RECEPTACLE AREA. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-06-14 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-06-14 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2017-06-14 15:17:35 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. | | | | | | 1. THIS PERMIT DOES NOT INCLUDE THE AREA IDENTIFIED AS | | | -OUTDOOR PATIO 100- ON SHEET A 0.5. A SEPARATE PROCESS, | | | SIDEWALK CAFE IS REQUIRED. BE ADVISED THAT OUTDOOR | | | FURNITURE SHALL NOT BE FIXED PERMANENTLY. ALL OUTDOOR | | | FURNITURE SHALL BE STORED AFTER OPERATION HOURS. | | | | | | 2. DUMPSTER SHALL BE PROPERLY SCREENED AND LANDSCAPED | | | MEETING THE REQUIREMENTS OF SECTION 94-315. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT KEVIN MARTIN, | | | URBAN DESIGN PLANNER, AT [email protected]. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-03-09 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-03-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-03-08 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2017-03-09 16:07:38 | 1. THIS PERMIT DOES NOT INCLUDE THE AREA IDENTIFIED AS | | | -OUTDOOR PATIO 100- ON SHEET A 0.5. A SEPARATE PROCESS, | | | SIDEWALK CAFE IS REQUIRED. BE ADVISED THAT OUTDOOR | | | FURNITURE SHALL NOT BE FIXED PERMANENTLY. ALL OUTDOOR | | | FURNITURE SHALL BE STORED AFTER OPERATION HOURS. | | | | | | 2. SHOW DUMPSTER ON THE SITE PLAN, ENSURE THAT IT IS | | | PROPERLY SCREENED AND LANDSCAPED MEETING THE | | | REQUIREMENTS OF SECTION 94-444. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT KEVIN MARTIN, | | | URBAN DESIGN PLANNER, AT [email protected]. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |