2017-03-31 14:50:29BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. RE-SUBMITTAL INCLUDES TWO PLAN PAGES MARKED 7 & 8.
 THESE PAGES HAVE NOT BEEN REVIEWED AND APPROVED BY
 DESIGNER OF RECORD.
 2. OROGINAL SET OF PLANS ALSO HAS PAGES 7 & 8. INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID. - OR -
 RE-DESIGNATE THE TWO NEW PLAN SHEETS AND INCORPORATE
 THEM INTO THE OFFICIAL SETS OF PLANS.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-06 Cont ID  
Sent By cthroop Date 2017-03-06 Time 09:06 Rev Time 0.00
Received By cthroop Date 2017-03-06 Time 08:41 Sent To  
Notes
2017-03-06 09:24:59BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IDENTIFY LOCATION OF STAIR HANDRAIL. REMOVAL OF
 FRAME WALL AT STAIRS SHALL NOT INTERFERE WITH STAIR
 GUARD AND HANDRAIL REQUIREMENTS.
 2. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS.
 3. PROVIDE STRUCTURAL DETAIL FOR EXTERIOR WALLL
 ALTERATIONS FOR NEW WINDOWS AND DOORS.
 4. PROVIDE WELDER CERTIFICATIONS FOR ANY ON-SITE
 WELDING.
 5. MECHANICAL EXHAUST REQUIRED FOR REMOVAL OF BATHROOM
 WINDOW.
 6. PROVIDE WINDOW AND DOOR "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES OR ASSEMBLIES" FOR THE
 "ASTRO GUARD" WIND ABATEMENT SYSTEM.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
 R311.7.8 HANDRAILS.
 HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF
 EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR
 MORE RISERS. R311.7.8.1 HEIGHT.
 FBCR312.1.1 GUARDS SHALL BE LOCATED ALONG OPEN-SIDED
 WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS,
 THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
 VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT
 WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF
 THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED
 AS A GUARD.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW, AND
 DOOR SUBMITTALS.
  
 PROVIDE COMPLETED CITY OF WEST PALM BEACH - SCHEDULE
 FOR INSTALLATION OF OPENING PROTECTIVE DEVICES AND
 ASSEMBLIES
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-05-02 Cont ID  
Sent By jleahy Date 2017-05-02 Time 14:51 Rev Time 0.00
Received By jleahy Date 2017-05-02 Time 14:51 Sent To  
Notes
2017-05-02 15:19:11JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
  
 THE FOLLOWING SHALL BE SUBMITTED FOR REVIEW PRIOR TO
 THE FINAL ELECTRICAL INSPECTION.
  
  
 1. FBC-RE 3601: SERVICE DISCONNECT SHALL BE SHOWN ON
 FLOORPLAN. IT SHALL BE MARKED AS REQUIRED.
 2. FBC-RE 3609: THE INTERSYSTEM BONDING TERMINAL SHALL
 BE INCLUDED AND SHOW ON THE SERVICE DIAGRAM.
 3. FBC-RE 3704: A SERVICE LOAD DIAGRAM SHALL BE
 PROVIDED AND A SERVICE DIAGRAM IS REQUIRED TO DETERMINE
 PROPER SIZING OF FEEDER CONDUCTORS.
 4. FBC-RE 3705: THE LOCATION OF ALL ELECTRICAL PANELS
 SHALL BE MARKED ON THE FLOORPLANS.
 5. FBC-RE 3901: TO COMPLY WITH THE OUTLET SPACING
 REQUIREMENTS OF THIS SECTION THERE IS AN OUTLET MISSING
 IN THE MASTER BEDROOM AND IN BEDROOM #2.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-04-06 Cont ID  
Sent By vperez Date 2017-04-06 Time 09:07 Rev Time 0.00
Received By vperez Date 2017-04-05 Time 11:42 Sent To  
Notes
2017-04-06 09:09:25PLEASE SEE PRIOR COMMENTS 5,6,7,9,10. SEE MARKUP ON
 PLANS SUBMITTED FOR ELECTRICAL APPROVAL COMPLIANCE. FBC
 107.3.5
  
 V. PEREZ
 *6717

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-02-06 Cont ID  
Sent By albarran Date 2017-02-06 Time 13:21 Rev Time 0.00
Received By albarran Date 2017-02-06 Time 11:29 Sent To  
Notes
2017-02-06 13:21:29ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH:
 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC)
  
 PROJECT NAME:
 JOB ADDRESS: 306 MARLBORO PL
 DESCRIPTION: COMPLETE INTERIOR REMODEL
 MASTER PERMIT: 17020082
  
 BELOW PLEASE FIND A LIST OF REQUIRED CORRECTIONS.
 ADDITIONAL CORRECTIONS MAY BE REQUIRED AFTER REVIEW OF
 SUBMITTED CORRECTIONS.
 1. ELECTRICAL SUB PERMIT REQUIRED.
 2. A SITE PLAN INDICATING THE LOCATION OF THE ELECTRIC
 SERVICE UTILITY POLE AND ELECTRICAL METERS SHALL BE
 SUBMITTED.
 3. FBC-RE 3601: SERVICE DISCONNECT SHALL BE SHOWN ON
 FLOORPLAN. IT SHALL BE MARKED AS REQUIRED.
 4. FBC-RE 3602: SERVICE LOAD SHALL BE CALCULATED AS
 INSTRUCTED AND SHOWN ON PLANS.
 5. FBC-RE 3609: THE INTERSYSTEM BONDING TERMINAL SHALL
 BE INCLUDED AND SHOW ON THE SERVICE DIAGRAM.
 6. FBC-RE 3704: A SERVICE LOAD DIAGRAM SHALL BE
 PROVIDED AND A SERVICE DIAGRAM IS REQUIRED TO DETERMINE
 PROPER SIZING OF FEEDER CONDUCTORS.
 7. FBC-RE 3705: THE LOCATION OF ALL ELECTRICAL PANELS
 SHALL BE MARKED ON THE FLOORPLANS.
 8. FBC-RE 3902: ARC-FAULT REQUIREMENTS EXTEND BEYOND
 THE BEDROOMS AS MENTIONED ON PLANS. CORRECT
 ACCORDINGLY.
 9. FBC-RE 3901: TO COMPLY WITH THE OUTLET SPACING
 REQUIREMENTS OF THIS SECTION THERE IS AN OUTLET MISSING
 IN THE MASTER BEDROOM AND IN BEDROOM #2.
 10. FBC-RE 3901: YOU SHALL MARK ON THE FLOORPLAN THE
 LOCATION OF ALL HVAC EQUIPMENT AND SHOW THE REQUIRED
 SERVICE OUTLETS AND ILLUMINATION.
 11. FBC-RE 3905: CEILING BOXES FOR THE SUPPORT OF
 PADDLE FANS SHALL BE LISTED FOR THE PURPOSE AND MARKED
 ACCORDINGLY.
 12. FBC-RE4001: THE GROUNDED CONDUCTOR SHALL BE
 PROVIDED AT THE SWITCH AS REQUIRED.
 13. FBC-RE4002: TAMPER-RESISTANT RECEPTACLES SHALL BE
 PROVIDED THROUGHOUT THE RESIDENCE.
 14. FBC-RE4003: RECESSED INCANDESCENT LUMINAIRES SHALL
 HAVE THERMAL PROTECTION AND SHALL BE LISTED AS
 THERMALLY PROTECTED.
 15. FBC-ER404.1 A MINIMUM OF 75% OF THE LAMPS IN
 PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE
 HIGH-EFFICACY LAMPS OR A MINIMUM OF 75% OF THE
 PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN
 ONLY HIGH EFFICIENCY LAMPS.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-03-31 Cont ID  
Sent By destabro Date 2017-03-31 Time 10:45 Rev Time 0.00
Received By destabro Date 2017-03-31 Time 10:45 Sent To B
Notes
2017-03-31 10:48:103/31/2017 - SPOKE W/APPLICANT - HISTORIC WINDOWS ARE TO
 BE RESTORED AND LATER PROTECTED WITH HURRICANE FABRIC;
 A 2ND STORY BATHROOM WINDOW WILL BE INFILLED; FRONT
 ENTRY WILL HAVE SLIDING GLASS DOORS REMOVED FOR A
 SINGLE FRONT DOOR; PAIRED WINDOWS ON THE EAST
 ELEVATION, GROUND FLOOR, WILL BE CHANGED TO FRENCH
 DOORS; AND LASTLY, ONE KITCHEN WINDOW WILL BE RAISED TO
 MATCH THE HEIGHT OF THE ADJACENT EXISTING WINDOW. HOUSE
 WILL BE RESTORED TO ITS ORIGINAL APPEARANCE. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By destabro Date 2017-03-22 Time 09:21 Rev Time 0.00
Received By destabro Date 2017-03-22 Time 09:21 Sent To B
Notes
2017-03-22 09:25:163/22/0217 - APPLICANT CONTACTED 3/14/2017 - NO
 RESPONSE. THIS IS A CONTRIBUTING PROPERTY TO THE
 PROSPECT PARK/SOUTHLAND PARK HISTORIC DISTRICT. A COA
 (FOUND HERE ON OUR WEBSITE) IS REQUIRED FOR THE
 PROPOSED WORK. SPECIFICALLY, THE APPLICANT MUST SPECIFY
 WHICH WINDOWS ARE TO BE RESTORED/REPLACED, AND ANY
 OTHER WORK THAT WILL MATERIALLY AFFECT THE EXTERIOR
 ENVELOPE. QUESTIONS MAY BE DIRECTED TO DESIREE
 ESTABROOK, HISTORIC PRESERVATION PLANNER AT
 561.822.1428.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-04-11 Cont ID  
Sent By hmoser Date 2017-04-11 Time 16:03 Rev Time 0.00
Received By hmoser Date 2017-03-28 Time 10:44 Sent To  
Notes
2017-03-29 10:45:08R19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-22 Cont ID  
Sent By hmoser Date 2017-03-22 Time 15:38 Rev Time 0.00
Received By hmoser Date 2017-02-02 Time 14:35 Sent To  
Notes
2017-02-02 14:35:33R11

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-05-02 Cont ID  
Sent By hmoser Date 2017-05-02 Time 15:51 Rev Time 0.00
Received By hmoser Date 2017-05-02 Time 15:30 Sent To  
Notes
2017-05-02 15:51:08PASS PROVISO
 1) PROVIDE EXHAUST FAN IN MASTER BATHROOM.
 2) PROVIDE INFORMATION ON KITCHEN EXHAUST HOOD
 AT FIRST INSPECTION
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-04-11 Cont ID  
Sent By hmoser Date 2017-04-11 Time 16:03 Rev Time 0.00
Received By hmoser Date 2017-04-11 Time 12:52 Sent To  
Notes
2017-04-11 16:03:15PLAN DENIED
 1) PROVIDE INFORMATION ON RANGE HOOD SECTION M1301.3
 2) REFER TO SECTION R303.3 BATHROOMS. YOU HAVE A
 EXHAUST FAN IN TOILET ROOM.
 NEED ONE IN BATHROOM.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By hmoser Date 2017-03-22 Time 15:38 Rev Time 0.00
Received By hmoser Date 2017-03-22 Time 14:46 Sent To  
Notes
2017-03-22 15:38:31PLAN DENIED
 1) PLEASE PROVIDE INFORMATION ON THE RANGE HOOD
 PER SECTION M1301.3 INSTALLATION OF MATERIALS.
 2014 RESIDENTIAL CODE.
 2) PROVIDE BATH EXHAUST FOR MASTER BATH
 R303.3 BATHROOMS 2014 FRC.
 3) PLEASE MAKE PLAN MORE LEGIBLE
 PER SECTION 107.2.1.4 QUALITY OF PLAN.
 2014 FBC .
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-04-11 Cont ID  
Sent By gjohnson Date 2017-04-11 Time 10:26 Rev Time 0.00
Received By gjohnson Date 2017-04-11 Time 10:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-02-10 Cont ID  
Sent By gjohnson Date 2017-02-10 Time 11:24 Rev Time 0.00
Received By gjohnson Date 2017-02-10 Time 10:11 Sent To  
Notes
2017-02-10 11:24:311ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHOW THE DIMENSION FOR THE GUEST BATHROOM SHOWER.
 PER WPB AMEN TO FBC 107.2.1
  
 2. THE WASHING MACHINE DRAIN SHALL CONNECT TO BUILDING
 DRAIN DOWN STEAM OF THE BATHROOM GROUP. PER FBC PL
 912.1
  
 3. SHT. 8 THE VENT FOR THE WC AND SHR IN GUEST BATHROOM
 IS SHOWN BEFORE THE WATER CLOSET ON THE PLAN VIEW IT
 SHALL CONNECT BETWEEN THE WC AND SHR AS REFLECTED ON
 THE RISER DIAGRAM. PER FBC PL 912.1
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved