Plan Review Details - Permit 17020076
Plan Review Stops For Permit 17020076
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-06-21 Cont ID  
Sent By shill Date 2017-06-21 Time 12:34 Rev Time 0.00
Received By shill Date 2017-06-21 Time 12:34 Sent To  
Notes
2017-06-21 12:35:43VERIFIED THAT SHEET A003, REVIEWED BY THE COUNTY, IS
 THE SAME VERSION AS THE ONE IN PROJECTDOX
 NO CHANGES TO THE DIGITAL PLANS SINCE LAST REVIEW
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-04-14 Cont ID  
Sent By shill Date 2017-04-14 Time 17:03 Rev Time 0.00
Received By shill Date 2017-04-14 Time 16:47 Sent To  
Notes
2017-04-14 17:03:28PROVISOS
  
 LOCKING HARDWARE NOT PERMITTED ON THE NORTH AND SOUTH
 GATES. FBC 1008.1.10, 1008.2.
  
 LOCKERS TO COMPLY WITH FBC A 803; DETAILS SHOWING
 COMPLIANCE TO BE PROVIDED AT INSPECTION. SUBJECT TO
 FIELD INSPECTOR'S DISCRETION, A SUBMITTAL OR REVISION
 MAY BE REQUIRED.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By shill Date 2017-03-22 Time 14:38 Rev Time 0.00
Received By shill Date 2017-03-21 Time 17:00 Sent To  
Notes
2017-03-22 14:40:12****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FOURTH FLOOR, RESTAURANT AND WINE VAULT, REVISED
 PLAN SHOWS SEATING. IS ANY OF THIS TO BE FIXED SEATING?
 FBC A 226, 902, REVISE PLAN TO CLARIFY AND PROVIDE
 DETAILS IF APPLICABLE.
  
 2. A050, J3-A107, IT APPEARS THAT OCCUPANTS OF THE
 FOURTH FLOOR A2 OCCUPANCY EXIT THROUGH THE STAIRS, THEN
 THR0UGH THE NORTH AND SOUTH GATES. FBC 1008.1.10,
 1008.2, REVISE TO INCLUDE THE FIRE EXIT OR PANIC
 HARDWARE REQUIRED, OR CLARIFY EXIT DISCHARGE FOR
 ASSEMBLY OCCUPANCY.
  
 3. 1ST FLOOR, REVISE PLAN TO CLARIFY USE OF LOCKERS. IT
 IS NOT CLEAR WHETHER OR NOT ACCESSIBILITY APPLIES; FBC
 A 803. IF ACCESSIBILITY APPLIES, THIS REVISION CAN BE
 ISSUED (UPON REQUEST) WITH A PROVISO THAT DETAILS BE
 PROVIDED PRIOR TO INSTALLATION.
  
 BREAKROOM 123 SHOWS LOCKERS. LOCKERS ARE TO BE
 ACCESSIBLE, FBC A 803; THIS REVISION WILL BE ISSUED
 WITH PROVISO THAT A DETAILS SHOWING COMPLIANCE BE
 PROVIDED AT INSPECTION. SUBJECT TO FIELD INSPECTOR'S
 DISCRETION, A SUBMITTAL OR REVISION MAY BE REQUIRED.
  
 HTTPS://WWW.ACCESS-BOARD.GOV/GUIDELINES-AND-STANDARDS/R
 ECREATION-FACILITIES/GUIDES/SPORTS-FACILITIES/DRESSING,
 -FITTING,-OR-LOCKER-ROOMS
  
 4. A120A AND OTHER SHEETS, WOMENS WC 471, DOOR 471.3
 APPEARS TO OBSTRUCT THE MANEUVERING CLEARANCE FOR DOOR
 471.2, REVISE, FBC A 404.2.4.
  
 5. IT APPEARS THAT THERE IS AN ADDITION OF SQUARE FOOT
 AREA. REVISE PLAN TO CLARIFY OLD TOTAL, NEW TOTAL.
 BUILDING DATA NEEDS TO BE UPDATED, BOTH ON THE PLAN AND
 IN OUR SYSTEM FOR RECORDKEEPING AND CO, AND ADDITIONAL
 IMPACT FEES MAY BE DUE. SEE IMPACT FEE REVIEW.
  
 6. THE ARCHITECTURAL SHEETS HAVE AN ERROR THAT
 "CERTIFICATION IS INVALID", BUT THE SIGNATURE SHOWS
 THAT IT WAS SIGNED BY WILLIAM HOBBS. PLEASE CONTACT
 ISSUER AND PROVIDE INFORMATION REGARDING THIS ERROR.
 PLEASE DO NOT UPLOAD NEW SHEETS UNLESS THEY ARE REVISED
 TO ADDRESS PLAN REVIEW COMMENTS, OR IF THE ISSUER OF
 DIGITAL SEAL/SIGNATURE ADVISES THAT SHEETS NEED TO BE
 RE-SIGNED/SEALED. FAC61G15-30, FS481.
  
 7. D3-A422 (AND POSSIBLY OTHER LOCATIONS) SPECS PT
 PLYWOOD. THIS IS A TYPE II BUILDING; SEE FBC B 603.1.
 IF DOR FEELS THIS FALLS UNDER AN EXCEPTION, REVISE
 DETAIL TO INCLUDE EXCEPTION AND SQUARE FOOT AREA
 AFFECTED. SEND VIA EMAIL FOR PRELIMINARY REVIEW AND
 ACCEPTANCE PRIOR TO RESUBMITTAL.
  
 8. MANY SHEETS REVIEWED APPEAR TO AFFECT OTHER PERMITS.
 FOR INSTANCE, THE HARDSCAPE REVIEWED UNDER THIS
 REVISION APPEARS TO AFFECT THE HARDSCAPE PERMIT
 16010525. AFTER THIS REVISION IS REVIEWED, COORDINATE
 WITH STEVE KENNEDY (OR WITH ME IF HE IS NOT AVAILABLE)
 TO HAVE THE OTHER PERMITS UPDATED. ADDITIONAL REVISIONS
 ARE NOT REQUIRED.
  
 9. PRIOR TO RESUBMITTAL, OR SUBMITTAL OF OTHER PERMITS
 AND/OR REVISIONS, CONTACT STEVE KENNEDY TO COORDINATE
 FEES.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-03-13 Cont ID  
Sent By vperez Date 2017-03-13 Time 12:03 Rev Time 0.00
Received By vperez Date 2017-03-13 Time 12:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-03-06 Cont ID  
Sent By pleduc Date 2017-03-06 Time   Rev Time 0.00
Received By pleduc Date 2017-03-06 Time 08:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-06-23 Cont ID  
Sent By lmarchan Date 2017-06-23 Time 15:37 Rev Time 0.00
Received By lmarchan Date 2017-06-16 Time 13:48 Sent To  
Notes
2017-06-19 13:48:51IMPACT FEES ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-04-17 Cont ID  
Sent By ccole Date 2017-04-17 Time 11:04 Rev Time 0.00
Received By ccole Date 2017-04-11 Time 09:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-22 Cont ID  
Sent By shill Date 2017-03-22 Time 14:40 Rev Time 0.00
Received By shill Date 2017-02-13 Time 16:03 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2017-06-21 Cont ID  
Sent By shill Date 2017-06-21 Time 12:44 Rev Time 0.00
Received By shill Date 2017-06-21 Time 12:25 Sent To  
Notes
2017-06-21 12:58:26MU-2015-019031
 MU-2017-015087
  
 TOTAL DUE $76,517.23
 ALL FEES DUE WERE PAID PER WILLIE SWOPE VIA EMAIL
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-04-14 Cont ID  
Sent By shill Date 2017-04-14 Time 17:04 Rev Time 0.00
Received By shill Date 2017-04-14 Time 17:04 Sent To  
Notes
2017-04-14 17:04:22IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
 REVISE PLAN TO CLARIFY ADDITIONAL UNDER AIR SQUARE
 FOOTAGE ADDED AND CONTACT 561-233-5025. THE PLAN IS TO
 BE STAMPED AND THE RECEIPT SHOWING THAT FEES DUE HAVE
 BEEN PAID (IF APPLICABLE) IS TO BE PROVIDED.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-03-22 Cont ID  
Sent By shill Date 2017-03-22 Time 09:18 Rev Time 0.00
Received By shill Date 2017-03-22 Time 09:18 Sent To  
Notes
2017-03-22 09:21:04IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
 REVISE PLAN TO CLARIFY ADDITIONAL UNDER AIR SQUARE
 FOOTAGE ADDED AND CONTACT 561-233-5025. THE PLAN IS TO
 BE STAMPED AND THE RECEIPT SHOWING THAT FEES DUE HAVE
 BEEN PAID (IF APPLICABLE) IS TO BE PROVIDED.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-04-17 Cont ID  
Sent By ccole Date 2017-04-17 Time 11:03 Rev Time 0.00
Received By ccole Date 2017-04-14 Time 15:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-03-03 Cont ID  
Sent By ccole Date 2017-03-03 Time 09:31 Rev Time 0.00
Received By ccole Date 2017-03-03 Time 07:14 Sent To  
Notes
2017-03-03 09:35:411ST REVIEW FBC-2014 MECHANICAL
 REVISION PERMIT #17020076
 3/3/17
  
 1) SHEET M-101: PLEASE REVISE KEY NOTE #9 TO INDICATE A
 DRAIN PAN UNDER THE UNIT WILL BE EQUIPPED WITH A
 ?WATER-LEVEL DETECTION DEVICE CONFORMING TO UL 508?
 ?SECTION 307.2.3 FBC-14 MECHANICAL.
  
 2) M-101, M-102, M-103: CLARIFY WHY THE MAIN RETURN
 DUCT AT EACH FLOOR LEVEL AND THE RISER IN GENERAL HAS
 BEEN REDUCED IN SIZE AND SHOW BOTH THE TOTAL RETURN AND
 SUPPLY CFMS AT EACH FLOOR LEVEL.
  
 3) M-101: THE NEW LOCKER ROOM REQUIRES AN EXHAUST
 SYSTEM SIZED AT .25 CFMS PER SQ. FT.
  
 4) M-102: INDICATE HOW AIR WILL BE RETURNED FROM THE
 NEW SWATCH ROOM. PLEASE REVIEW ALL LEVELS TO VERIFY ALL
 ENCLOSED ROOMS ARE EQUIPPED WITH RETURNS WHERE
 REQUIRED.
  
 5) M-102: PLEASE CLOUD THE LOCATION OF THE JANITOR?S
 CLOSET AND PROVIDE AN EXHAUST SYSTEM PER TABLE 6-4
 ASHRAE 62.1-2010.
  
 6) M-103: INDICATE THE SIZES OF THE SUPPLY DUCT RISERS
 FROM VRV 52 & 53.
  
 7) M-104: PROVIDE THE BRANCH DUCT SIZES SUPPLYING THE
 REGISTERS IN THE RESTAURANT.
  
 8) M-301: PLEASE NOTE THAT TABLE 6-4 ASHRAE 62.1-2010
 REQUIRES AN EXHAUST SYSTEM SIZED AT 1.00 CFM PER SQ.
 FT. FOR THE TRASH ROOM. ASHRAE 62.1 IS REFERENCED IN
 THE FBC-14 MECHANICAL CODE
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-13 Cont ID  
Sent By tlarge Date 2017-03-13 Time 10:34 Rev Time 0.00
Received By gjohnson Date 2017-03-10 Time 16:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2017-04-14 Cont ID  
Sent By shill Date 2017-04-14 Time 17:14 Rev Time 0.00
Received By shill Date 2017-04-14 Time 17:14 Sent To  
Notes
2017-04-17 11:05:35MECHANICAL DIG/SIGS GOOD.
 CCOLE 4/17/17
2017-04-14 17:06:524/14 VERIFIED ALL TRADES
  
  
  
  
2017-03-22 09:46:353/22 SEE BUILDING REVIEW REGARDING ARCH SHEETS
 (CERTIFICATION NOT VALID ERROR); S SHEETS OK
  
  
  
  
2017-03-13 10:36:563/13/17 DIG SIGNATURES ON PLUMBING PAGES OK GPJ

Review Stop Z ZONING
Rev No 2 Status P Date 2017-06-23 Cont ID  
Sent By eschneid Date 2017-06-23 Time 14:46 Rev Time 0.50
Received By eschneid Date 2017-06-23 Time 14:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-03-07 Cont ID  
Sent By eschneid Date 2017-03-07 Time 14:08 Rev Time 2.00
Received By eschneid Date 2017-03-07 Time 09:45 Sent To  
Notes
2017-03-07 14:11:13PASSED
  
 1) PLEASE NOTE THAT AN AS BUILT MINOR AMENDMENT IS
 REQUIRED PRIOR TO C.O. THE PLANS NEED TO CALL OUT THE
 ADDITIONAL SQUARE FOOTAGE ON THE 4TH FLOOR.
  
  
 2) IN ACCORDANCE WITH RESOLUTION NO. 206-16, PRIOR TO
 THE ISSUANCE OF THE C.O., THE FOLLOWING SHALL OCCUR:
  
 A. RECORD A PUBLIC ACCESS EASEMENT FOR ANY PUBLIC
 SIDEWALKS OR UTILITIES ON THE SITE. THE EASEMENT
 LANGUAGE SHALL BE APPROVED BY THE CITY ATTORNEY'S
 OFFICE.
 B. ABANDON THE UNUSED FPL EASEMENT ON THE NORTH
 PROPERTY LINE.
 C. CONSTRUCT THE PEDESTRIAN CROSSING OF WESTBOUND
 OKEECHOBEE BOULEVARD FROM THE CITYPLACE OFFICE PARCEL
 TO THE RESTORATION HARDWARE PARCEL IN ACCORDANCE WITH A
 FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY
 PERMIT APPROVAL AND TIE IT INTO THE SIDEWALK NETWORK ON
 THE EAST SIDE OF THE RESTORATION HARDWARE SITE. A COPY
 OF THE FLORIDA DEPARTMENT OF TRANSPORTATION
 RIGHT-OF-WAY PERMIT SHALL BE PROVIDED TO THE PLANNING
 DIVISION.
 D. CONSTRUCT THE MODIFICATIONS TO THE PEDESTRIAN
 CROSSING OF OKEECHOBEE BOULEVARD AT ROSEMARY AVENUE
 (EAST SIDE) TO BE IN COMPLIANCE WITH PLANS APPROVED BY
 THE FLORIDA DEPARTMENT OF TRANSPORTATION AND THE CITY.
 A COPY OF THE FLORIDA DEPARTMENT OF TRANSPORTATION
 RIGHT-OF-WAY PERMIT SHALL BE PROVIDED TO THE PLANNING
 DIVISION.
 E. RECORD A RESTRICTIVE COVENANT, APPROVED BY THE CITY
 ATTORNEY?S OFFICE, REQUIRING THAT THE TANDEM PARKING
 CONFIGURATION OF THE SURFACE PARKING LOT BE MAINTAINED
 AS A VALET ONLY FACILITY.
  


Account Summary | Usage Policy | Privacy Policy