Plan Review Details - Permit 17011210
Plan Review Stops For Permit 17011210
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-04-13 Cont ID  
Sent By jgomez Date 2017-04-13 Time 16:12 Rev Time 0.00
Received By jgomez Date 2017-04-13 Time 15:31 Sent To P
Notes
2017-04-13 15:37:28 
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-03-31 Cont ID  
Sent By jgomez Date 2017-03-31 Time 17:49 Rev Time 0.00
Received By jgomez Date 2017-03-31 Time 14:13 Sent To  
Notes
2017-03-31 15:00:53RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- REVISED ENERGY CALCULATIONS FORM R405-2014
 SUBMITTED:
 A) OWNER DIDN'T CERTIFIED CODE COMPLIANCE AT THE BOTTOM
 OF FORM AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 NOTE: IT WAS DONE ON THE ORIGINAL SUBMITTAL BUT NOT ON
 THE REVISED ONE. PERMIT CAN NOT BE ISSUED WITHOUT THE
 OWNER'S CERTIFICATION.
  
 B) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED
 BY SEC. R405.4.3 FBC-ENERGY CONSERVATION.
 RESPONSE: REPEAT COMMENT. EPL DISPLAY CARD WAS NOT
 COMPLETED BY THE BUILDER. BUILDER NEEDS TO FILL THIS
 FORM. SEE EPL DISPLAY CARD IN THE ENERGY CALCULATIONS
 PACKAGE.
  
 C) INFORMATION ON TOP OF FORM SUBMITTED IS INCORRECT.
 PROVIDE THE CORRECT BUILDER'S NAME. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 RESPONSE: BUILDER'S NAME IS INCORRECT AGAIN.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION DIDN'T
 INCLUDE THE DESIGN PROFESSIONAL FEES AS REQUIRED BY
 SEC. 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED TO
 INCLUDE THE DESIGN FEES OF ALL DESIGN PROFESSIONALS.
 VALUATION WAS ROUNDED TO $50,000 +/- TO INCLUDE THE
 DESIGN FEES OF ALL ENGINEERS INVOLVED IN THIS PROJECT.
 THE PERMIT FEE BALANCE IS $1235.88.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-03-09 Cont ID  
Sent By jgomez Date 2017-03-09 Time 18:01 Rev Time 0.00
Received By jgomez Date 2017-03-09 Time 07:46 Sent To  
Notes
2017-03-08 19:00:36RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- ALTERATION LEVEL SPECIFIED ON SHEET T-1 UNDER THE
 DESIGN CRITERIA IS INCORRECT. ACCORDING TO THE SCOPE OF
 WORK SHOWN ON PLAN SUBMITTED, THIS IS ALTERATION LEVEL
 3 NOT 2. REVISE AS REQUIRED. SEC. 505 FBC-EXISTING
 BUILDING, 5TH EDITION (2014).
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS
 REQUIRED BY SEC. 109.3 CITY AMENDMENTS. PROVIDE COPY OF
 SIGNED CONTRACT THAT INCLUDES ALL THE SCOPE OF WORK.
  
 3- SPECIFY SELF CLOSING DEVICE FOR GARAGE DOOR LEADING
 TO THE FAMILY ROOM AREA AS REQUIRED BY SEC. R302.5.1
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 4- REVISE ENERGY CALCULATIONS FORM R405-2014 SUBMITTED;
 A) INFORMATION ON TOP OF FORM SUBMITTED IS INCORRECT.
 PROVIDE THE CORRECT OWNER AND BUILDER NAME. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 B) ITEM #1 IS INCORRECT. THIS IS NOT NEW CONSTRUCTION.
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 C) NUMBER OF BEDROOMS SPECIFIED ON ITEM #4 IS
 INCORRECT. REVISE AS REQUIRED TO MATCH PROPOSED PLANS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 D) PROVIDE THE INFORMATION FOR THE HOT WATER ON ITEM
 #14. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 E) ENGINEER WHO PREPARED THE ENERGY CALCULATIONS TO
 PROVIDE HIS INFORMATION AS REQUIRED BY FAC 61G15-23.002
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 F) ROOF INFORMATION ON PAGE 3 OF 5 IS INCORRECT. THIS
 HOUSE DOESN'T HAVE SHINGLES. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 G) ATTIC INFORMATION ON PAGE 3 OF 5 SPECIFIES 1/300
 VENT RATIO. THE MINIMUM VENT RATIO REQUIRED BY SEC.
 R806.2 FBC-RESIDENTIAL IS 1/150. PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS SHOWING HOW THE EXISTING
 HOUSE COMPLIES WITH THE 1/300 VENT RATIO AS REQUIRED BY
 THE EXCEPTION OF SEC. R806.2. OTHERWISE REVISE THE
 SPECIFIED VENT RATIO.
  
 H) THE ORIENTATION OF THE WALLS AND WINDOWS DON'T MATCH
 ACTUAL BUILDING ORIENTATION. REVISE AS REQUIRED TO
 MATCH THE ACTUAL ORIENTATION OF THE BUILDING. SEE
 SURVEY AND REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 I) REVISE THE WINDOWS OVERHANG DEPTH ON PAGE 4 OF 5 TO
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 J) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED
 BY SEC. R405.4.3 FBC-ENERGY CONSERVATION.
  
 5- A) IT'S NOT CLEAR WHICH WINDOWS ARE GOING TO BE
 REPLACED. CLARIFY WHY SUBMITTING NOA 16-0714.06 FOR
 SINGLE HUNG WINDOWS?. CLEARLY SPECIFY ON PLANS WHICH
 DOORS AND WINDOWS ARE GOING TO BE REPLACED. SEC.
 107.2.1 CITY AMENDMENTS. NOTE: WINDOW "G" FOR PROPOSED
 BEDROOM #2 DOESN'T SEEM TO COMPLY WITH THE EGRESS
 REQUIREMENTS. CLARIFY IF THIS WINDOW IS GOING TO BE
 REPLACED. IF SO, THEN SPECIFY TYPE AND SIZE OF EXISTING
 WINDOW AND TYPE AND SIZE OF PROPOSED WINDOW TO VERIFY
 COMPLIANCE WITH SEC 704 FBC-EXISTING BUILDING, 5TH
 EDITION (2014).
  
 B) NOA 16-0218.03 SUBMITTED FOR MULLIONS. PLANS DON'T
 SHOW ANY WINDOW AND MULLION REPLACEMENT. CLARIFY WHERE
 IS THE HIGHLIGHTED MULLION SIZE SHOWN ON SHEET 5 OF 25
 GOING TO BE INSTALLED. SEC. 107.2.1 CITY AMENDMENTS.
 COORDINATE WITH ITEM #5(A) ABOVE.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) INSWING ENTRY DOORS AS SHOWN ON PROPOSED PLAN
 SUBMITTED. NOA 16-0629.16 SUBMITTED IS FOR "OUTSWING"
 DOORS ONLY.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-03-29 Cont ID  
Sent By vperez Date 2017-03-29 Time 10:04 Rev Time 0.00
Received By vperez Date 2017-03-29 Time 10:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-02-15 Cont ID  
Sent By vperez Date 2017-02-15 Time 13:20 Rev Time 0.00
Received By vperez Date 2017-02-15 Time 13:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-13 Cont ID  
Sent By jgomez Date 2017-04-13 Time 16:12 Rev Time 0.00
Received By jgomez Date 2017-04-07 Time 11:21 Sent To  
Notes
2017-04-10 11:22:05JGOMEZ'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-31 Cont ID  
Sent By jgomez Date 2017-03-31 Time 19:06 Rev Time 0.00
Received By jgomez Date 2017-03-24 Time 13:59 Sent To  
Notes
2017-03-27 13:59:32R29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-03-10 Cont ID  
Sent By jgomez Date 2017-03-10 Time 11:23 Rev Time 0.00
Received By jgomez Date 2017-01-31 Time 13:50 Sent To  
Notes
2017-02-01 13:50:42R29

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-03-31 Cont ID  
Sent By jgomez Date 2017-03-31 Time 19:02 Rev Time 0.00
Received By jgomez Date 2017-03-31 Time 18:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-03-10 Cont ID  
Sent By jgomez Date 2017-03-10 Time 08:39 Rev Time 0.00
Received By jgomez Date 2017-03-10 Time 08:38 Sent To  
Notes
2017-03-10 08:46:03RESIDENTIAL (R3) ALTERATION, MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 1- EQUIPMENT SIZING CALCULATIONS SUBMITTED:
 A) THE DESIGN INFORMATION OF THE PROJECT SUMMARY
 CALCULATIONS SUBMITTED SPECIFIES MIAMI INTERNATIONAL
 AIRPORT. THIS IS NOT THE CORRECT LOCATION FOR THIS
 HOUSE. REVISE AS REQUIRED. SEC. R403.6 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 B) ONLY THE PROJECT SUMMARY SHEET WAS SUBMITTED.
 PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS FOR THE
 ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED BY SEC.
 R403.6 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 NOTE: SEE SURVEY FOR CORRECT HOUSE ORIENTATION. ALSO,
 COORDINATE EQUIPMENT SIZING CALCULATIONS WITH THE
 REQUIRED REVISED ENERGY CALCULATIONS.
  
 C) ENGINEER WHO PREPARED THE ENERGY CALCULATIONS TO
 PROVIDE HIS INFORMATION AS REQUIRED BY FAC 61G15-23.002
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 2- TRANSFER DUCT SIZE SPECIFIED ON SHEET M-1 FOR THE
 MASTER BEDROOM DOESN'T COMPLY WITH THE BALANCED RETURN
 AIR SEC. M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014).
 DUCT NEEDS TO BE SIZED BASED ON ALL THE SUPPLY AIR
 GOING INTO THE MASTER BEDROOM. SEE EXCEPTION #3 ON SEC.
 M1602.4. REVISE AS REQUIRED.
  
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-04-14 Cont ID  
Sent By gjohnson Date 2017-04-14 Time 13:30 Rev Time 0.00
Received By gjohnson Date 2017-04-14 Time 13:30 Sent To  
Notes
2017-04-13 16:32:06NEW DRAWING P-2 SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-03-09 Cont ID  
Sent By gjohnson Date 2017-02-16 Time 11:59 Rev Time 0.00
Received By gjohnson Date 2017-02-16 Time 10:18 Sent To  
Notes
***NONE***