Plan Review Details - Permit 17011206
Plan Review Stops For Permit 17011206
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-02-28 Cont ID  
Sent By jwitmer Date 2017-02-28 Time 13:18 Rev Time 0.00
Received By jwitmer Date 2017-02-28 Time 11:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-02-03 Cont ID  
Sent By jwitmer Date 2017-02-03 Time 11:42 Rev Time 0.00
Received By jwitmer Date 2017-02-03 Time 10:37 Sent To  
Notes
2017-02-03 11:42:01BUILDING PLAN REVIEW
 W. P. B. REVISION: 17011206
 W. P. B. PERMIT: 16041056
 ADD: 701 VILLAGE BLVD. SUITES: 201-202
 CONT: GREAT PATRIOT CONSTRUCTION
 TEL: 561-241-4765
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. FEB.03/ 2017
 ACTION: DENIED
  
 1) SHEET A2 THE SERVICE COUNTER DOES NOT INDICATE
 COMPLIANCE WITH DISPLAY AND SERVICE COUNTERS BY
 SPECIALIST TO COMPLY WITH ADA CHAPTER 3 REQUIREMENTS AS
 SHEET 05-A. SEE 2014 FBC-ACCESS. CODE:
 904.3.2 COUNTER. THE COUNTER SURFACE HEIGHT SHALL BE 38
 INCHES (965 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND. THE TOP OF THE COUNTER EDGE PROTECTION SHALL BE
 2 INCHES (51 MM) MAXIMUM ABOVE THE TOP OF THE COUNTER
 SURFACE ON THE AISLE SIDE OF THE CHECK-OUT COUNTER.
  
 2) SHEET A2 ON THE RIGHT SIDE OF THE BAR THERE IS A
 STATEMENT ADA AT BAR BUT DOES NOT INDICATE HOW
 COMPLIANCE WILL BE MET. WHERE DINING SURFACES ARE
 PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK
 COMPLIANCE WITH ACCESS. CODE SECTION 902.3 HEIGHT. THE
 TOPS OF DINING SURFACES SHALL BE 28 INCHES MINIMUM AND
 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 3A) SHOW COMPLIANCE WITH ACCESS. CODE SECTION WHERE
 DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF
 FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES
 AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY
 WITH 902.
  
 3B) 2014 ACCESS. CODE 226.2 DISPERSION. DINING SURFACES
 AND WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE
 DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING
 DINING SURFACES AND WORK SURFACES.
  
 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING
 WITH 306 SHALL BE PROVIDED.
  
 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK
 SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34
 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-27 Cont ID  
Sent By vperez Date 2017-02-27 Time 13:27 Rev Time 0.00
Received By vperez Date 2017-02-27 Time 13:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-02-10 Cont ID  
Sent By vperez Date 2017-02-10 Time 12:07 Rev Time 0.00
Received By vperez Date 2017-02-10 Time 12:07 Sent To  
Notes
2017-02-10 12:20:07ALTHOUGH ELECTRICAL IS IN COMPLIANCE, A LETTER
 INDICATING A CHANGE OF DESIGN PROFESSIONAL IS REQUIRED
 TO AHJ. FS 61G15-27.001
  
 V. PEREZ
 *6717

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-02-27 Cont ID  
Sent By pleduc Date 2017-02-27 Time   Rev Time 0.00
Received By pleduc Date 2017-02-24 Time 15:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-02-02 Cont ID  
Sent By pleduc Date 2017-02-02 Time   Rev Time 0.00
Received By pleduc Date 2017-02-02 Time 16:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-07 Cont ID  
Sent By gjohnson Date 2017-03-07 Time 12:53 Rev Time 0.00
Received By gjohnson Date 2017-02-21 Time 14:16 Sent To  
Notes
2017-02-22 14:16:54C09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-02-10 Cont ID  
Sent By gjohnson Date 2017-02-10 Time 14:58 Rev Time 0.00
Received By gjohnson Date 2017-01-31 Time 13:46 Sent To  
Notes
2017-02-01 13:47:09C09

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-03-07 Cont ID  
Sent By gjohnson Date 2017-03-07 Time 12:36 Rev Time 0.00
Received By gjohnson Date 2017-03-06 Time 15:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-02-10 Cont ID  
Sent By gjohnson Date 2017-02-10 Time 14:53 Rev Time 0.00
Received By gjohnson Date 2017-02-10 Time 14:53 Sent To  
Notes
2017-02-10 14:57:521ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE COMPLY WITH FAC 61G15-27.001 PROCEDURES FOR A
 SUCCESSOR PROFESSIONAL ENGINEER ADOPTING AS HIS OWN THE
 WORK OF ANOTHER ENGINEER.
 (1) A SUCCESSOR PROFESSIONAL ENGINEER SEEKING TO REUSE
 ALREADY SEALED CONTRACT DOCUMENTS UNDER THE SUCCESSOR
 PROFESSIONAL ENGINEER'S SEAL MUST BE ABLE TO DOCUMENT
 AND PRODUCE UPON REQUEST EVIDENCE THAT HE HAS IN FACT
 RECREATED ALL THE WORK DONE BY THE ORIGINAL
 PROFESSIONAL ENGINEER. IN OTHER WORDS, CALCULATIONS,
 SITE VISITS, RESEARCH AND THE LIKE MUST BE DOCUMENTED
 AND PRODUCEABLE UPON DEMAND. FURTHER, THE SUCCESSOR
 PROFESSIONAL ENGINEER MUST TAKE ALL PROFESSIONAL AND
 LEGAL RESPONSIBILITY FOR THE DOCUMENTS WHICH HE SEALED
 AND SIGNED AND CAN IN NO WAY EXEMPT HIMSELF FROM SUCH
 FULL RESPONSIBILITY. PLANS NEED NOT BE REDRAWN BY THE
 SUCCESSOR PROFESSIONAL ENGINEER; HOWEVER, JUSTIFICATION
 FOR SUCH ACTION MUST BE AVAILABLE THROUGH WELL KEPT AND
 COMPLETE DOCUMENTATION ON THE PART OF THE SUCCESSOR
 PROFESSIONAL ENGINEER AS TO HIS HAVING RETHOUGHT AND
 REWORKED THE ENTIRE DESIGN PROCESS. A SUCCESSOR
 PROFESSIONAL ENGINEER MUST USE HIS OWN TITLE BLOCK,
 SEAL AND SIGNATURE AND MUST REMOVE THE TITLE BLOCK,
 SEAL AND SIGNATURE OF THE ORIGINAL PROFESSIONAL
 ENGINEER BEFORE REUSING ANY SEALED CONTRACT DOCUMENTS.
 (2) PRIOR TO SEALING AND SIGNING WORK A SUCCESSOR
 PROFESSIONAL ENGINEER SHALL BE REQUIRED TO NOTIFY THE
 ORIGINAL PROFESSIONAL ENGINEER, HIS SUCCESSORS, OR
 ASSIGNS BY CERTIFIED LETTER TO THE LAST KNOWN ADDRESS
 OF THE ORIGINAL PROFESSIONAL ENGINEER OF THE
 SUCCESSOR'S INTENTION TO USE OR REUSE THE ORIGINAL
 PROFESSIONAL ENGINEER'S WORK. THE SUCCESSOR
 PROFESSIONAL ENGINEER WILL TAKE FULL RESPONSIBILITY FOR
 THE DRAWING AS THOUGH THEY WERE THE SUCCESSOR
 PROFESSIONAL ENGINEER'S ORIGINAL PRODUCT.
  
  
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  