| Plan Review Stops For Permit 17011191 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-29 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-29 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2018-03-29 09:33:23 | 03/29/18 TALKED TO ABRAHAM RAYMOND (OWNER). HE | | | CONFIRMED THAT EXISTING BEDROOM #2 AND BEDROOM #3 HAD | | | 25SH WINDOWS INSTALLED. WHILE TALKING TO HIM OVER THE | | | PHONE I ASKED HIM TO MEASURE THE WINDOW OPENINGS. HE | | | SAID CLEAR OPENING HEIGHT WAS 26" AND CLEAR OPENING | | | WIDTH WAS 33". | | | | | | | | | | | | | | | BUILDING REVIEW APPROVED WITH PROVISO (NO FEES, UNLESS | | | ANY APPROVED PRODUCT APPROVAL IS CHANGED): | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: HURRICANE | | | SHUTTERS FOR DOORS. FRENCH DOORS NOA 16-0629.15 | | | SUBMITTED IS FOR NON-IMPACT DOORS. AND, PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | 2- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE | | | PRODUCT APPROVALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-29 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-29 |
Time |
12:49 |
Sent To |
E |
|
| Notes |
| 2017-08-29 12:54:00 | BUILDING REVIEW APPROVED WITH PROVISO (NO FEES, UNLESS | | | ANY APPROVED PRODUCT APPROVAL IS CHANGED): | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: HURRICANE | | | SHUTTERS FOR DOORS. FRENCH DOORS NOA 16-0629.15 | | | SUBMITTED IS FOR NON-IMPACT DOORS. AND, PROVIDE | | | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | 2- ENGINEER OF RECORD TO APPROVE IN WRITING ABOVE | | | PRODUCT APPROVALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-26 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-26 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2017-05-26 11:01:39 | RESIDENTIAL (R3) ADDITION, THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO ONCE THE | | | ENERGY CALCULATIONS ARE SIGNED BY THE OWNER AND THE | | | PLANS ARE SUBMITTED WITH THE COUNTY IMPACT FEES STAMP | | | AND COPY OF PAID RECEIPT IF FEES ARE DUE. PROVISO MEANS | | | THAT OWNER MAY PROVIDE THE REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED AND BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | | OWNER/BUILDER TO ADVICE IN WRITING IF PROVISO OPTION IS | | | PREFERRED AT THIS TIME. (RESPONSE MAY BE DONE BY | | | RESPONDING TO THIS E-MAIL). | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | | | | ORIGINAL COMMENT: | | | 2- ENERGY CALCULATIONS SUBMITTED: | | | A) OWNER TO CERTIFY COMPLIANCE AT THE BOTTOM OF THE | | | FORM AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | B) PROVIDE THE NAME OF THE PERSON COMPLETING THE | | | CALCULATIONS A REQUIRED BY SEC. R405.4.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | C)PROVIDE CORRECT INFORMATION ON TOP OF FORM. ON TARGET | | | IS NOT THE BUILDER. REVISE AS REQUIRED BY SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | D) BUILDER (OWNER/BUILDER) TO COMPLETE THE ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD AS REQUIRED BY | | | SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | ORIGINAL COMMENT: | | | A) NEW ROOF RIDGE VENTS AS SPECIFIED ON PLANS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | B) EXTERIOR DOORS AS SHOWN ON PLANS. | | | RESPONSE: PROVIDE FLORIDA PRODUCT APPROVAL COVER SHEET | | | THAT CORRESPONDS TO DRAWINGS SUBMITTED AND PROVIDE | | | COMPLETE AND CLEAR DRAWINGS. DRAWINGS SUBMITTED ARE CUT | | | OFF. NEED COMPLETE DRAWINGS. UNCUT DRAWINGS. | | | REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | RESPONSE: PROVIDE FLORIDA PRODUCT APPROVAL COVER SHEET | | | THAT CORRESPONDS TO DRAWINGS SUBMITTED AND PROVIDE | | | COMPLETE AND CLEAR DRAWINGS. DRAWINGS SUBMITTED ARE CUT | | | OFF. NEED COMPLETE DRAWINGS. UNCUT DRAWINGS. | | | REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | ORIGINAL COMMENT: | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | | | | NOTE: | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | | SHEETS. DON'T STAPLE OLD SHEETS. SUBMIT OLD SHEETS FOR | | | REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-10 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-10 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2017-05-10 14:55:15 | RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO ONCE THE | | | ENERGY CALCULATIONS ARE SIGNED BY THE OWNER AND THE | | | COUNTY IMPACT FEES ARE PAID. PROVISO MEANS THAT OWNER | | | MAY PROVIDE THE REQUIRED INFORMATION AFTER THE PERMIT | | | IS ISSUED AND BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | | OWNER/BUILDER TO ADVICE IN WRITING ( RESPONDING TO THIS | | | E-MAIL) IF PROVISO OPTION IS PREFERRED AT THIS TIME. | | | | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | | | | 2- ENERGY CALCULATIONS SUBMITTED: | | | A) OWNER TO CERTIFY COMPLIANCE AT THE BOTTOM OF THE | | | FORM AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | B) PROVIDE THE NAME OF THE PERSON COMPLETING THE | | | CALCULATIONS A REQUIRED BY SEC. R405.4.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | C) PROVIDE CORRECT INFORMATION ON TOP OF FORM. ON | | | TARGET IS NOT THE BUILDER. REVISE AS REQUIRED BY SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | D) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | | (EPL) DISPLAY CARD AS REQUIRED BY SEC. R405.4.3 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) NEW ROOF RIDGE VENTS AS SPECIFIED ON PLANS. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | B) EXTERIOR DOORS AS SHOWN ON PLANS. | | | RESPONSE: PROVIDE FLORIDA PRODUCT APPROVAL COVER SHEET | | | THAT CORRESPONDS TO DRAWINGS SUBMITTED AND PROVIDE | | | COMPLETE AND CLEAR DRAWINGS. DRAWINGS SUBMITTED ARE CUT | | | OFF. NEED COMPLETE DRAWINGS. UNCUT DRAWINGS. | | | | | | C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | RESPONSE: PROVIDE FLORIDA PRODUCT APPROVAL COVER SHEET | | | THAT CORRESPONDS TO DRAWINGS SUBMITTED AND PROVIDE | | | COMPLETE AND CLEAR DRAWINGS. DRAWINGS SUBMITTED ARE CUT | | | OFF. NEED COMPLETE DRAWINGS. UNCUT DRAWINGS. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | | SHEETS. DON'T STAPLE OLD SHEETS. SUBMIT OLD SHEETS FOR | | | REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-03-08 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-03-08 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2017-03-07 18:57:48 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014) | | | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | 3- ENGINEER OF RECORD TO PROVIDE SPECIFICATIONS SHOWING | | | COMPLIANCE WITH THE HEATING REQUIREMENTS OF SEC. R303.9 | | | FBC-RESIDENTIAL, 5TTH EDITION (2014). | | | | | | 4- ACCORDING TO PLANS SUBMITTED THE PROPOSED SCOPE OF | | | WORK IS NOT ALTERATION LEVEL 2. THIS IS AND ADDITION. | | | SEC. 507 FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | REVISE AS REQUIRED INFORMATION ON SHEET 1 AND 2 OF 8. | | | | | | 5- SHEET 3 OF 8: | | | A) NEED TO PROVIDE A LANDING AT THE NEW EXTERIOR DOOR | | | LOCATED ON THE EAST SIDE AS REQUIRED BY SEC. R311.3 | | | FBC-RESIDENTIAL. SPECIFY LANDING AND DIMENSIONS. | | | | | | B) NEED TO SPECIFY THE RISER AND TREAD DIMENSIONS FOR | | | THE NEW STAIRS LOCATED ON THE EAST SIDE SHOWING | | | COMPLIANCE WITH SEC. R311.7.5 FBC-RESIDENTIAL. | | | | | | C) WINDOW ADJACENT TO THE NEW BATHROOM NEEDS TO HAVE | | | SAFETY GLAZING AS REQUIRED BY SEC. R308.4 | | | FBC-RESIDENTIAL IF THE WINDOW DOESN'T HAVE IMPACT | | | GLASS. | | | | | | NOTE: FLOOR PLAN SHOWS EXISTING BEDROOMS #2 AND #3 WITH | | | 24SH WINDOWS. THIS HOUSE WAS BUILT IN 2006. THESE | | | WINDOWS DON'T COMPLY WITH THE EGRESS HEIGHT | | | REQUIREMENTS OF SEC. R310.1.2 FBC-RESIDENTIAL (2014). | | | THIS HOUSE WAS APPROVED UNDER PERMIT #05050247 WITH THE | | | CONDITION THAT BEDROOM WINDOWS WILL NEED TO BE REVISED | | | TO COMPLY. THIS ISSUE WILL BE BROUGHT TO THE ATTENTION | | | OF THE BUILDING OFFICIAL FOR REQUIRED ACTION ON THIS | | | ISSUE SINCE THERE ARE 2 OTHER HOUSES THAT WERE APPROVED | | | WITH THE SAME CONDITION AND APPARENTLY WAS NOT DONE. | | | | | | | | | 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING | | | COMPLIANCE WITH THE VENTILATION REQUIREMENTS OF SEC. | | | R806 FBC-RESIDENTIAL. CLEARLY SPECIFY VENT SIZE AND | | | LOCATIONS IN ROOF FRAMING PLAN. | | | | | | 7- WINDOW AND DOOR STRUCTURAL BUCK DETAIL ON SHEET 6 OF | | | 8: CLEARLY SPECIFY SIZE OF TAPCONS TO BE USED. SPECIFY | | | HOW MUCH EMBEDMENTS IS REQUIRED. PROVIDE CALCULATIONS | | | SHOWING THAT THE SPECIFIED DIAMETER OF THE TAPCONS IS | | | ADEQUATE TO RESIST THE WIND LOADS. SEC. R301.1 | | | FBC-RESIDENTIAL. COORDINATE WITH WINDOWS AND DOORS | | | PRODUCT APPROVALS SUBMITTED. | | | ALSO, NOTE LOCATED BELOW THE WINDOW/DOOR BUCK DETAIL IS | | | NOT CLEAR. CLARIFY WHAT MEANS "DOORS/WINDOWS TO BE | | | INSTALLED TO 1" P.T. BUCK W/3/16" DIA. TAPCONS WITH A | | | MINIMUM EMBEDMENT OF 1-1/2" @ MANUFACTURER'S SUPPLIED | | | HOLES". SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ROOF SHINGLES AS SPECIFIED ON PLANS. | | | | | | B) ROOF RIDGE VENTS AS SPECIFIED ON PLANS. | | | | | | C) EXTERIOR DOORS AS SHOWN ON PLANS. | | | | | | D) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | | | E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | "IMPACT" GLASS. AND PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | | | | F) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | 9- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 10- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT (EVEN IF OWNER IS | | | ACTING AS A CONTRACTOR) AND ALL DESIGN PROFESSIONAL | | | FEES AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. | | | VALUATION WAS UPDATED TO $35,000 +/-. THE PERMIT FEE | | | BALANCE IS $809.56. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | | SHEETS. DON'T STAPLE OLD SHEETS. SUBMIT OLD SHEETS FOR | | | REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-29 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-29 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-02 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-02 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2017-06-02 07:19:08 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | 3RD REVIEW: | | | | | | 1. PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL QUALIFIER. THE SIGNATURE | | | ON THE ELECTRICAL PLAN IS DIFFICULT TO READ AND THERE | | | IS NO LICENSE INFORMATION WITH THE SIGNATURE. I WAS NOT | | | ABLE TO FIND ANY LICENSE INFORMATION FOR THE COMPANY | | | "ON TARGET DESIGN", OR BY TRYING TO SEARCH THE NAME OF | | | THE SIGNER. PROVIDE CORRECTION. FS 471.003(2)(H), | | | 471.025 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-05-01 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-05-01 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-05-01 |
Time |
18:33 |
Sent To |
P |
|
| Notes |
| 2017-05-01 18:35:34 | PLEASE HAVE DESIGNER OF RECORD SIGN AND SEAL ELECTRICAL | | | SHEET #8. PLANS HAVE BEEN STAMPED. BEFORE RELEASING | | | APPROVAL, SEAL IS REQUIRED. FBC 107.3.5 | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-02-15 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-15 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-15 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2017-02-15 11:00:15 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | | | | ADDRESS ZONING COMMENTS AND HAVE DESIGNER OF RECORD | | | SIGN AND SEAL PLANS SUBMITTED, FBC 107.3.5 | | | | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-03-29 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-03-29 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2018-03-29 09:34:42 | 03/29/18 OVER THE PHONE CONVERSATION WITH OWNER TO | | | CLARIFY EGRESS WINDOWS ISSUE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-25 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2017-08-29 12:50:37 | MARC RE-SUBMITTED PLANS AND PRODUCT APPROVALS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-05 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-12 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-10 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-04-20 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-03-08 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-31 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-29 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-29 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2017-08-29 13:09:21 | NO FEES DUE. MU-2017-24536. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-26 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-26 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-10 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-10 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2017-05-10 17:57:22 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY | | | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT | | | CODE. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-03-08 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-03-08 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2017-03-08 07:49:09 | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. | | | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF | | | THE UNIFIED LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-10 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-10 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-03-08 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-03-08 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2017-03-08 15:48:26 | RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014) | | | | | | 1- NO INFORMATION SUBMITTED FOR REVIEW. IF ADDITION IS | | | GOING TO HAVE AIR CONDITIONING, THEN PROVIDE COMPLETE | | | EQUIPMENT SIZING CALCULATIONS AND COMPLETE MECHANICAL | | | PLANS LISTING EQUIPMENT REFERENCED IN THE EQUIPMENT | | | SIZING CALCULATIONS AS REQUIRED BY SEC. R403.6.1 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED SHEET AND REMOVE OLD | | | SHEETS. DON'T STAPLE OLD SHEETS. SUBMIT OLD SHEETS FOR | | | REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-09-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-01 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-01 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-05 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-05 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2017-06-05 12:59:40 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: I SUGGEST A MEETING BE SCHEDULED TO | | | CLARIFY COMMENTS IN ORDER TO EXPEDITE AN APPROVAL FOR | | | PLUMBING. | | | | | | 1. PROVIDE CODE COMPLIANT SANITARY RISER THE NEW TUB , | | | TOILET AND LAVATORY ARE NOT VENTED. PER FBC RES | | | P3101.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | PREVIOUS COMMENT COMMENT: | | | | | | 1. THE PLUMBING AND ELECTRICAL SHEET SHALL BE SIGN AND | | | SEALED BY THE DESIGNER OF RECORD. PER FAC 61G15-23.001 | | | ( SEE ELECTRICAL COMMENT) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-03 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-03 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2017-05-03 08:53:26 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS HAVE NOT BEEN | | | COMPLIED WITH. | | | | | | 1. THE LAVATORY STACKS SHOULD CONNECT TO THE WC BRANCH | | | DRAIN NOT THE BUILDING DRAIN. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE TUBS SHOULD CONNECT TO HORIZONTAL DRAIN FOR THE | | | BATHROOM GROUP NOT THE VERTICAL STACK. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | NEW COMMENT: | | | | | | 1. THE PLUMBING AND ELECTRICAL SHEET SHALL BE SIGN AND | | | SEALED BY THE DESIGNER OF RECORD. PER FAC 61G15-23.001 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-15 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-15 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2017-02-15 17:32:09 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE LAVATORY STACKS SHOULD CONNECT TO THE WC BRANCH | | | DRAIN NOT THE BUILDING DRAIN. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE TUBS SHOULD CONNECT TO HORIZONTAL DRAIN FOR THE | | | BATHROOM GROUP NOT THE VERTICAL STACK. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2017-08-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-29 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-29 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2017-08-29 15:07:40 | | | | SHINGLES NOA 14-1022.16 IS OK. | | | RIDGE VENT NOA 14-1224.18 IS OK. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-26 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-26 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2017-05-26 13:27:41 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ROOF RIDGE VENTS AS SPECIFIED ON PLANS. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | | | | NOTE: | | | SHINGLES NOA 14-1022.16 IS OK. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-10 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-10 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2017-05-10 18:00:07 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ROOF RIDGE VENTS AS SPECIFIED ON PLANS. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | | | | NOTE: SHINGLES NOA 14-1022.16 IS OK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-03-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-03-08 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-03-08 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-04-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-04-25 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-07 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-02-07 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2017-02-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-02-07 12:51:38 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PROVIDE AN UPDATED SURVEY OF THE PROPERTY (<1 YEAR | | | OLD). | | | | | | 2.) PROVIDE A SITE PLAN ILLUSTRATING THE PROPOSED | | | ADDITION TO THE EXISTING STRUCTURE. THE SITE PLAN SHALL | | | INCLUDE SETBACK DIMENSIONS FROM THE PROPERTY LINE. | | | | | | REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 | | | IF THERE ARE QUESTIONS. | | | | | | | | | NOTE: | | | | | | - VALUE OF SCOPE DOES NOT EXCEED 50% OF THE BUILDING | | | VALUE. | | | |
|
|