| Plan Review Stops For Permit 17010953 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-13 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2017-04-13 17:04:42 | BUILDING PROVISO | | | | | | 1) THE (3) EXISTING WINDOWS AND STORM PANELS THAT WERE | | | INSTALLED UNDER PERMIT #02030400 WERE REMOVED AND | | | RE-INSTALLED IN THE RE-BUILT WALLS. THE CONTRACTOR | | | SHALL PROVIDE THE INSTALLATION INSTRUCTIONS TO THE | | | FIELD INSPECTOR. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-31 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-31 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2017-01-31 14:48:37 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ALL OF THE CHANGES SHOULD BE CLOUDED AND HAVE THE | | | REVISION NUMBER TAG. THE LENGTH DIMENSION OF THE | | | ADDITION, THE DIMENSION BETWEEN THE TWO DOORS, THE | | | KITCHEN DIMENSION, THE NEW A/C AREA, THE NEW TOTAL AREA | | | AND THE NOTE TO FRAME IN THE BATHROOM WINDOW WERE ALL | | | CHANGES TO THE APPROVED DRAWINGS. FBC 107.2.1 | | | | | | 2) PROVIDE A WINDOW INFILL DETAIL ON THE PLANS. FBC | | | 107.2.1.3 | | | | | | 3) ON SHEET 02 AN EXTRA WINDOW IS SHOWN IN THE EXISTING | | | BEDROOM THAT IS NOT SHOWN ON THE FLOOR PLAN OR THE | | | RIGHT ELEVATION ON SHEET 01. PLEASE CLARIFY. FBC | | | 107.2.1 | | | | | | 4) THE APPROVED REVISIED PLANS WILL BE REQUIRED TO HAVE | | | ANOTHER IMPACT FEE REVIEW BY PALM BEACH COUNTY PER | | | PHONE CALL TO WILLIE SWOOPE AT PBC. | | | | | | 5) THE REVISION FORM STATES THAT THERE IS NO INCREASE | | | IN THE VALUE OF THE WORK. SPECIFY THE ADDITIONAL COST | | | FOR THE ADDED SQUARE FOOTAGE ON THE REVISION | | | APPLICATION AND INFORM THE PERMIT CLERK SO THAT THE | | | ADJUSTMENT CAN BE MADE. FBC 109.3 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-04-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-04-10 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-04-10 |
Time |
15:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-01-30 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-30 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-30 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
| 2017-01-30 15:41:33 | 1ST REVISION 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] PLEASE SHOW RECEPTACLE OUTLET SPACING IN NEW DINING | | | ROOM PER FBC-R SECTION E3901.2.1. | | | | | | 2] ADD A GFCI RECEPTACLE OUTLET NEXT TO KITCHEN SINK | | | COUNTERTOP SPACE PER FBC-R SECTION E3901.4. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-07 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2017-04-07 11:37:48 | SENT TO RMCDOUGA DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-31 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-25 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2017-01-27 10:14:40 | REVISION ROUTED TO MVALDES |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-13 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2017-04-13 15:22:52 | MU 2017 -8276, NO FEES WERE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-31 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-31 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2017-01-31 15:41:00 | THE REVISION ADDS SQUARE FOOTAGE TO THE ADDITION. THE | | | REVISED PLANS REQUIRE AN IMPACT FEE REVIEW BY PALM | | | BEACH COUNTY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-13 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2017-04-13 16:57:12 | MECHANICAL WORK CONSISTS OF INSTALLATION OF EXHAUST | | | VENT IN BATHROOM AND KITCHEN. NO OTHER MECHANICAL WORK | | | IS SHOWN ON THE PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-01-31 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-31 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2017-01-31 13:54:30 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R303.3 REQUIRES BATHROOMS TO HAVE A WINDOW WITH | | | NOT LESS THAN 3 SQFT OF GLAZED AREA ONE-HALF OF WHICH | | | IS OPENABLE OR ARTIFICAL LIGHT AND A LOCAL EXHAUST PER | | | SECTION M1507. | | | |
|
|