Plan Review Details - Permit 17010911
| Plan Review Stops For Permit 17010911 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-02 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-23 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-02 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-02 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2017-06-02 13:51:38 | OLD ADDRESS: 3200 N CONGRESS | | | NEW PROPOSED ADDRESS: 2020 BANYAN RESORT WAY | | | CHANGE ADDRESS PRIOR TO PERMIT ISSUANCE | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2018-07-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-19 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-19 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2018-07-19 13:25:25 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | BANYAN CAY FOUR STORY HOTEL **FOUNDATION ONLY** | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - JORGE E. REYES, PE54904 | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS HAVE BEEN VOIDED AS THEY ARE NOT | | | CORRECT AND ARE INCOMPLETE. SUBMIT WITH VERTICAL | | | BUILDING PERMIT. | | | | | | F. PRIOR TO COMMENCEMENT, SCHEDULE A PRE-CONSTRUCTION | | | MEETING WITH KEN CONRAD, CHIEF BUILDING INSPECTOR. | | | SCHEDULE A 143 BUILDING MISC INSPECTION AND ADVISE THAT | | | IT IS A PRE-CON MEETING. THE CONTRACTOR AND ON SITE | | | INSPECTOR SHOULD ATTEND TO DISCUSS PROCEDURE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-11 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-11 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2018-07-11 17:57:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | BANYAN CAY FOUR STORY HOTEL **FOUNDATION ONLY** | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - JORGE E. REYES, PE54904 | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | 1-3. OK | | | | | | 4. SEE SIGNATURE REVIEW. THE STRUCTURAL SHEETS | | | PREVIOUSLY SUBMITTED WERE DIGITALLY SIGNED AND SEALED; | | | THE SHEETS SUBMITTED THIS REVIEW CYCLE ARE NOT | | | DIGITALLY SIGNED AND SEALED. | | | | | | 5-13. OK | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS HAVE BEEN VOIDED AS THEY ARE NOT | | | CORRECT AND ARE INCOMPLETE. SUBMIT WITH VERTICAL | | | BUILDING PERMIT. | | | | | | F. SHORING/RESHORE ENGINEERING IS TO BE SUBMITTED TO | | | THE CITY, REVIEWED AND ISSUED PRIOR TO INSTALLATION. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-12 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2018-05-13 09:29:08 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | BANYAN CAY FOUR STORY HOTEL **FOUNDATION ONLY** | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - JORGE E. REYES, PE54904 | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | 1. SEE THRESHOLD REVIEW. A 100% COMPLETE SI AGREEMENT | | | WILL BE ACCEPTED VIA EMAIL; THREE ORIGINALS REQUIRED | | | AFTER PRELIMINARY REVIEW. | | | | | | 2. SEE IMPACT REVIEW. IF YOU WOULD LIKE TO SUBMIT A | | | REQUEST TO HAVE IMPACT FEES COLLECTED PRIOR TO ISSUANCE | | | OF VERTICAL CONSTRUCTION, SEND THE REQUEST (ADDRESSED | | | TO ROBERT BROWN, BUILDING OFFICIAL) VIA EMAIL TO | | | [email protected]. THE BUILDING OFFICIAL IS REQUIRED TO | | | MAKE THIS REQUEST OF PALM BEACH COUNTY AND IT IS NOT | | | GUARANTEED TO BE GRANTED. | | | | | | 3. FROM PREVIOUS REVIEWS, SEOR IS TO REVIEW THE SOILS | | | REPORT. RESPONSE LETTER STATES THAT STRUCTURAL DRAWINGS | | | HAVE BEEN REVISED TO REFERENCE THE REPORT FROM | | | UNIVERSAL. SEE SHEET S0.00, 310000-FOUNDATIONS, REVISE | | | TO INCORPORATE GEOTECHNICAL REPORT (CURRENTLY "XXXX"), | | | OR ADVISE WHERE THIS REVISION HAS BEEN MADE (PAGE | | | NUMBER). | | | | | | 4. SEE SIGNATURE REVIEW. | | | | | | 5. DISTANCE TO PROPERTY LINES - OK; PLEASE ADVISE, WHEN | | | WILL REPLAT BE FINALIZED? | | | | | | 10. FS471, FS481, ARCHITECTS AND ENGINEERS HAVE | | | REQUIREMENTS TO HAVE A TITLE BLOCK ON EACH SHEET WHICH | | | INCLUDES THE PRINTED NAME AND LICENSE NUMBER, COMPANY | | | LICENSE NUMBER (AS WELL AS OTHER INFORMATION). | | | | | | STRUCTURAL ENGINEER OF RECORD HAS A COMPLIANT TITLE | | | BLOCK ON ALL S SHEETS. | | | MEP AND ARCH TITLE BLOCKS NEED BUSINESS LICENSE NUMBER | | | ADDED. PLEASE REVISE BUT ONLY UPLOAD PAGES WHICH CHANGE | | | DUE TO CODE RELATED COMMENTS TO AVOID ANOTHER 100% | | | REVIEW BY ALL TRADES (BUT FIX TITLE BLOCK SO REVIEW | | | DOES NOT FAIL WHEN REVISIONS ARE SUBMITTED). | | | | | | 11. SEE VERTICAL BUILDING PERMIT, COMMENTS #2 AND #3 | | | REGARDING EXIT DISCHARGE AND ACCESSIBLE MEANS OF | | | EGRESS. ARCHITECT MAY PROVIDE A SIGNED AND SEALED | | | LETTER INDICATING UNDERSTANDING AND COMPLIANCE AND | | | STATE THAT THESE TWO COMMENTS WILL NOT AFFECT HEIGHT OR | | | LOCATION OF THE FOUNDATION. SINCE THIS NEEDS ANOTHER | | | BUILDING REVIEW DUE TO WRONG STRUCTURAL PAGES | | | SUBMITTED, PLEASE PROVIDE AT TIME OF RESUBMITTAL IN | | | "SUPPORTING DOCUMENTS". | | | | | | 12. WHEN RESUBMITTING, PLEASE REMOVE KITCHEN DESIGN | | | PAGES; THESE SHEETS HAVE NOT BEEN REVIEWED AND SHOULD | | | NOT BE A PART OF A FOUNDATION PERMIT. ALSO, IF | | | POSSIBLE, RENAME THE THREE SITE PLANS WHICH APPEAR AT | | | THE END OF SUBMITTAL DUE TO INCONSISTENT NAMING | | | CONVENTION. THE SAME PAGES SUBMITTED FOR THE VERTICAL | | | BUILDING PERMIT SHOULD BE SUBMITTED WITH THE SAME | | | NAMES, SAME VERSION. ONE SITE PLAN IS DATED 6/1/2017; | | | IS THIS CURRENT? PLEASE CORRELATE. | | | | | | 13. THE STRUCTURAL SHEETS IN THIS SUBMITTAL (FOR | | | EXAMPLE, SHEET S0.02) WAS SEALED 10/2/17. AFTER THAT | | | DATE, THERE WAS A DESIGN CHANGE (HEIGHT INCREASE) WHICH | | | AFFECTED THE STRUCTURAL PAGES. MORE RECENT PAGES DATED | | | 3/16/18 WERE UPLOADED TO THE VERTICAL BUILDING PERMIT. | | | UPDATE ALL PAGES TO THE MOST CURRENT DESIGN. | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS HAVE BEEN VOIDED AS THEY ARE NOT | | | CORRECT AND ARE INCOMPLETE. SUBMIT WITH VERTICAL | | | BUILDING PERMIT. | | | | | | F. SUBMIT RECORDED REPLAT PRIOR TO C.O. THE BOOK/PAGE | | | MAY BE SENT VIA EMAIL. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-02 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-23 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2018-04-02 17:04:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | FROM PREVIOUS LIST: | | | | | | 1. SEE THRESHOLD REVIEW. | | | | | | 3. SOIL BEARING VALUES; 2014 FBC-B 1803.3 | | | 2ND REVIEW, NOT ADDRESSED. PROVIDE A CURRENT REPORT. | | | HAVE SEOR INCORPORATE A SPECIFIC REFERENCE TO THE | | | UPDATED SOILS REPORT ON THE PLAN, OR PROVIDE A SHOP | | | DRAWING REVIEW OF THE SOILS REPORT. | | | 3RD REVIEW, RESPONSE LETTER STATES "SEE ATTACHED FROM | | | UNIVERSAL ENGINEERS." IT IS NOT CLEAR HOW THIS COMMENT | | | HAS BEEN ADDRESSED. SEE SHEET S0.00, | | | 310000-FOUNDATIONS, REVISE TO INCORPORATE GEOTECHNICAL | | | REPORT (CURRENTLY "XXXX"). | | | 4TH REVIEW, NOT ADDRESSED. | | | 5TH REVIEW, NOT ADDRESSED. ALL STRUCTURAL SHEETS WERE | | | UPLOADED ON 12/20/2017; NO NEW SHEETS SUBMITTED. | | | | | | 4. SEE SIGNATURE REVIEW. | | | 5TH REVIEW, THE STRUCTURAL SHEETS ARE NOT DIGITALLY | | | SIGNED AND SEALED. FS471, UPLOAD DIGITALLY SIGNED AND | | | SEALED STRUCTURAL SHEETS. | | | | | | 5. 2ND REVIEW, SET BACK/ SEPARATION FROM PROPOSED | | | BUILDING TO PROPERTY LINE(S) AND TO ASSUMED PROPERTY | | | LINES IS REQUIRED, FBC B 705.3. DEPENDING ON THE | | | LOCATION OF THE PROPERTY LINES AND/OR ASSUMED PROPERTY | | | LINES, INFORMATION REGARDING AFFECTED BUILDINGS OR | | | PROPOSED BUILDINGS MAY ALSO BE REQUIRED. | | | PRIOR TO RESUBMITTING, PLEASE CONFIRM THAT THE SITE | | | PLAN WHICH WILL BE REVIEWED NEXT CYCLE INCLUDES NEW | | | PROPERTY LINES (REPLAT). AS SHEETS WERE NOT CHANGED, | | | THIS WAS NOT REVIEWED AT THIS TIME. | | | | | | 5TH REVIEW - NOT CLEAR HOW THIS WAS ADDRESSED. | | | | | | 6. OK | | | | | | 7. SEE SIGNATURE REVIEW. | | | | | | 8. SEE IMPACT FEE REVIEW. | | | | | | 9-12. OK | | | | | | 13. WHEN RESUBMITTING, A TRANSMITTAL LETTER EXPLAINING | | | ALL CHANGES IS REQUIRED FBC 107. THIS IS NOT REQUIRED | | | WHEN CHANGES ARE OBVIOUS. THIS RESUBMITTAL INCLUDES A | | | NEW SET OF STRUCTURAL DRAWINGS, BUT STRUCTURAL COMMENT | | | NOT ADDRESSED, AND NO NEW ARCHITECTURAL SHEETS SO IT IS | | | NOT CLEAR IF ARCHITECT DISAGREES WITH THE COMMENT, | | | FEELS THE COMMENT WAS ADDRESSED, OR IF SHEETS WERE | | | INADVERTENTY NOT UPLOADED FOR REVIEW. | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS WERE NOT THOROUGHLY REVIEWED. WHEN | | | RESUBMITTING THE BUILDING, ADDRESS THE FOLLOWING: | | | WATER HEATER COMPLIANCE IS BLANK | | | NO DOORS SHOWN | | | CHECK ALL | | | | | | 15. NEW COMMENT - FS553, A 4X PLAN REVIEW FEE IS | | | REQUIRED TO BE ASSESSED IF THE SAME PLAN REVIEW COMMENT | | | HAS BEEN MADE A THIRD TIME. NOTE THAT COMMENT #5 HAS | | | NOT BEEN ADDRESSED, 5TH REVIEW. WE HAD A MEETING | | | REGARDING THIS ISSUE. NOTE THAT PLAN REVIEW FEE IS | | | $6178. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-10 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-10 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2018-01-10 07:07:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | FROM PREVIOUS LIST: | | | | | | 1. SEE THRESHOLD REVIEW. | | | | | | 3. SOIL BEARING VALUES; 2014 FBC-B 1803.3 | | | | | | 2ND REVIEW, NOT ADDRESSED. PROVIDE A CURRENT REPORT. | | | HAVE SEOR INCORPORATE A SPECIFIC REFERENCE TO THE | | | UPDATED SOILS REPORT ON THE PLAN, OR PROVIDE A SHOP | | | DRAWING REVIEW OF THE SOILS REPORT. | | | | | | 3RD REVIEW, RESPONSE LETTER STATES "SEE ATTACHED FROM | | | UNIVERSAL ENGINEERS." IT IS NOT CLEAR HOW THIS COMMENT | | | HAS BEEN ADDRESSED. SEE SHEET S0.00, | | | 310000-FOUNDATIONS, REVISE TO INCORPORATE GEOTECHNICAL | | | REPORT (CURRENTLY "XXXX"). | | | | | | 4TH REVIEW, NOT ADDRESSED. | | | | | | 4. SEE SIGNATURE REVIEW. | | | | | | WITHOUT A RESPONSE LETTER, IT IS NOT CLEAR HOW | | | APPLICANT INTENDS TO RESOLVE THIS COMMENT. STRUCTURAL | | | PAGE STILL REFERS TO A REPORT OF "XXXX". | | | | | | 5. 2ND REVIEW, SET BACK/ SEPARATION FROM PROPOSED | | | BUILDING TO PROPERTY LINE(S) AND TO ASSUMED PROPERTY | | | LINES IS REQUIRED, FBC B 705.3. DEPENDING ON THE | | | LOCATION OF THE PROPERTY LINES AND/OR ASSUMED PROPERTY | | | LINES, INFORMATION REGARDING AFFECTED BUILDINGS OR | | | PROPOSED BUILDINGS MAY ALSO BE REQUIRED. | | | | | | A NOTE ON THE PLANS (A0.0.02) STATES THAT THIS BUILDING | | | IS OVER 30 FEET FROM OTHER BUILDINGS AND/OR LOT LINES. | | | IT IS NOT CLEAR WHERE THE PROPERTY LINES ARE LOCATED. | | | DISTANCE BETWEEN BUILDINGS NOT CLEAR (FOR INSTANCE - | | | PROPOSED HOTEL TO BUILDING 11 ON SHEET C2, PROPOSED | | | HOTEL TO PARKING GARAGE, HOTEL TO CLUBHOUSE), LOCATION | | | OF ASSUMED PROPERTY LINE(S) NOT CLEAR. | | | | | | 3RD REVIEW, RESPONSE LETTER HAS NO RESPONSE FOR THIS | | | ITEM. IT IS NOT CLEAR HOW THIS ITEM HAS BEEN ADDRESSED. | | | | | | FOR INSTANCE - A NOTE ON THE PLAN STATES "EXTERIOR | | | OPENING PROTECTION: BUILDING SEPARATION >/=20' NO | | | LIMIT." ALTHOUGH THE NOTE STATES THAT THE BUILDING IS | | | OVER 30' FROM OTHER BUILDINGS AND/OR LOT LINES, IT IS | | | NOT CLEAR WHERE THE ASSUMED PROPERTY LINE, OR THE | | | PROPERTY LINE IS LOCATED. SEE ALSO 107.3.5.1.1(1),SET | | | BACK/SEPARATION (ASSUMED PROPERTY LINES). | | | | | | 4TH REVIEW - ALL STRUCTURAL SHEETS WERE CHANGED, BUT NO | | | RESPONSE OR TRANSMITTAL LETTER WAS PROVIDED WHICH | | | EXPLAINED THE CHANGES. NONE OF THE ARCHITECTURAL SHEETS | | | WERE CHANGED. IT IS NOT CLEAR HOW THIS WAS ADDRESSED. | | | | | | PRIOR TO RESUBMITTING, PLEASE CONFIRM THAT THE SITE | | | PLAN WHICH WILL BE REVIEWED NEXT CYCLE INCLUDES NEW | | | PROPERTY LINES (REPLAT). AS SHEETS WERE NOT CHANGED, | | | THIS WAS NOT REVIEWED AT THIS TIME. | | | | | | 6. OK | | | | | | 7. SEE SIGNATURE REVIEW. | | | | | | 8. SEE IMPACT FEE REVIEW. | | | | | | 9. OK | | | | | | 10. FS471, FS481, ARCHITECTS AND ENGINEERS HAVE | | | REQUIREMENTS TO HAVE A TITLE BLOCK ON EACH SHEET WHICH | | | INCLUDES THE PRINTED NAME AND LICENSE NUMBER, COMPANY | | | LICENSE NUMBER (AS WELL AS OTHER INFORMATION). | | | | | | STRUCTURAL ENGINEER OF RECORD HAS A COMPLIANT TITLE | | | BLOCK ON ALL S SHEETS. HOWEVER, REGARDING THE | | | ARCHITECTURAL SHEETS, IT NOT CLEAR WHO IS SEALING THESE | | | SHEETS. THE ARCHITECTURAL SHEETS LACK A TITLE BLOCK. | | | THERE IS A BAR WITH ALL OF THE DESIGN PROFESSIONALS. | | | THE ENGINEER'S NAME IS IN THE "SEAL" BLOCK. REVISE | | | ARCHITECTURAL SHEETS TO INCLUDE ALL INFORMATION | | | REQUIRED BY FAC61G16, FS481. | | | | | | 3RD REVIEW: ENGINEER'S NAME WAS REMOVED FROM THE | | | SHEETS, ARCHITECT'S NAME DID NOT REPLACE ENGINEER'S | | | NAME. FOR EXAMPLE, SEE SHEET A0.0.02; THIS SHEET IS | | | REQUIRED TO BE SIGNED AND SEALED AS IT IS REQUIRED TO | | | DEMONSTRATE CODE COMPLIANCE. SEE FS481, A TITLE BLOCK | | | FOR THE ARCHITECT IS REQUIRED, INCLUDING THE | | | ARCHITECT'S PRINTED NAME AND LICENSE NUMBER, ARCHITECT | | | BUSINESS LICENSE NUMBER. THIS COMMENT APPLIES TO OTHER | | | (POSSIBLY ALL) A SHEETS. | | | | | | SEE SHEET A0.0.02; "APPLICABLE CODES" INCLUDES A | | | REFERENCE TO THE BROWARD COUNTY AMENDMENTS TO THE FFPC, | | | REVISE. | | | | | | THRESHOLD STATEMENT FOR A SHEETS LACK A REFERENCE TO | | | THE BUILDING CODE; REVISE. | | | | | | 4TH REVIEW, NONE OF THE ARCHITECTURAL SHEETS WERE | | | CHANGED. IT IS NOT CLEAR HOW THIS WAS ADDRESSED. | | | | | | 11-12. OK | | | | | | 13. WHEN RESUBMITTING, A TRANSMITTAL LETTER EXPLAINING | | | ALL CHANGES IS REQUIRED FBC 107. THIS IS NOT REQUIRED | | | WHEN CHANGES ARE OBVIOUS. THIS RESUBMITTAL INCLUDES A | | | NEW SET OF STRUCTURAL DRAWINGS, BUT STRUCTURAL COMMENT | | | NOT ADDRESSED, AND NO NEW ARCHITECTURAL SHEETS SO IT IS | | | NOT CLEAR IF ARCHITECT DISAGREES WITH THE COMMENT, | | | FEELS THE COMMENT WAS ADDRESSED, OR IF SHEETS WERE | | | INADVERTENTY NOT UPLOADED FOR REVIEW. | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS WERE NOT THOROUGHLY REVIEWED. WHEN | | | RESUBMITTING THE BUILDING, ADDRESS THE FOLLOWING: | | | WATER HEATER COMPLIANCE IS BLANK | | | NO DOORS SHOWN | | | CHECK ALL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-06 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-02 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2017-06-06 10:54:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | FROM PREVIOUS LIST: | | | | | | 1. SEE THRESHOLD REVIEW. | | | | | | 3. SOIL BEARING VALUES; 2014 FBC-B 1803.3 | | | | | | 2ND REVIEW, NOT ADDRESSED. PROVIDE A CURRENT REPORT. | | | HAVE SEOR INCORPORATE A SPECIFIC REFERENCE TO THE | | | UPDATED SOILS REPORT ON THE PLAN, OR PROVIDE A SHOP | | | DRAWING REVIEW OF THE SOILS REPORT. | | | | | | 3RD REVIEW, RESPONSE LETTER STATES "SEE ATTACHED FROM | | | UNIVERSAL ENGINEERS." IT IS NOT CLEAR HOW THIS COMMENT | | | HAS BEEN ADDRESSED. SEE SHEET S0.00, | | | 310000-FOUNDATIONS, REVISE TO INCORPORATE GEOTECHNICAL | | | REPORT (CURRENTLY "XXXX"). | | | | | | 4. SEE SIGNATURE REVIEW. | | | | | | 5. 2ND REVIEW, SET BACK/ SEPARATION FROM PROPOSED | | | BUILDING TO PROPERTY LINE(S) AND TO ASSUMED PROPERTY | | | LINES IS REQUIRED, FBC B 705.3. DEPENDING ON THE | | | LOCATION OF THE PROPERTY LINES AND/OR ASSUMED PROPERTY | | | LINES, INFORMATION REGARDING AFFECTED BUILDINGS OR | | | PROPOSED BUILDINGS MAY ALSO BE REQUIRED. | | | | | | A NOTE ON THE PLANS (A0.0.02) STATES THAT THIS BUILDING | | | IS OVER 30 FEET FROM OTHER BUILDINGS AND/OR LOT LINES. | | | IT IS NOT CLEAR WHERE THE PROPERTY LINES ARE LOCATED. | | | DISTANCE BETWEEN BUILDINGS NOT CLEAR (FOR INSTANCE - | | | PROPOSED HOTEL TO BUILDING 11 ON SHEET C2, PROPOSED | | | HOTEL TO PARKING GARAGE, HOTEL TO CLUBHOUSE), LOCATION | | | OF ASSUMED PROPERTY LINE(S) NOT CLEAR. | | | | | | 3RD REVIEW, RESPONSE LETTER HAS NO RESPONSE FOR THIS | | | ITEM. IT IS NOT CLEAR HOW THIS ITEM HAS BEEN ADDRESSED. | | | | | | FOR INSTANCE - A NOTE ON THE PLAN STATES "EXTERIOR | | | OPENING PROTECTION: BUILDING SEPARATION >/=20' NO | | | LIMIT." ALTHOUGH THE NOTE STATES THAT THE BUILDING IS | | | OVER 30' FROM OTHER BUILDINGS AND/OR LOT LINES, IT IS | | | NOT CLEAR WHERE THE ASSUMED PROPERTY LINE, OR THE | | | PROPERTY LINE IS LOCATED. SEE ALSO 107.3.5.1.1(1),SET | | | BACK/SEPARATION (ASSUMED PROPERTY LINES). | | | | | | 6. OK | | | | | | 7. SEE SIGNATURE REVIEW. | | | | | | 8. SEE IMPACT FEE REVIEW. | | | | | | 9. OK | | | | | | 10. FS471, FS481, ARCHITECTS AND ENGINEERS HAVE | | | REQUIREMENTS TO HAVE A TITLE BLOCK ON EACH SHEET WHICH | | | INCLUDES THE PRINTED NAME AND LICENSE NUMBER, COMPANY | | | LICENSE NUMBER (AS WELL AS OTHER INFORMATION). | | | | | | STRUCTURAL ENGINEER OF RECORD HAS A COMPLIANT TITLE | | | BLOCK ON ALL S SHEETS. HOWEVER, REGARDING THE | | | ARCHITECTURAL SHEETS, IT NOT CLEAR WHO IS SEALING THESE | | | SHEETS. THE ARCHITECTURAL SHEETS LACK A TITLE BLOCK. | | | THERE IS A BAR WITH ALL OF THE DESIGN PROFESSIONALS. | | | THE ENGINEER'S NAME IS IN THE "SEAL" BLOCK. REVISE | | | ARCHITECTURAL SHEETS TO INCLUDE ALL INFORMATION | | | REQUIRED BY FAC61G16, FS481. | | | | | | 3RD REVIEW: ENGINEER'S NAME WAS REMOVED FROM THE | | | SHEETS, ARCHITECT'S NAME DID NOT REPLACE ENGINEER'S | | | NAME. FOR EXAMPLE, SEE SHEET A0.0.02; THIS SHEET IS | | | REQUIRED TO BE SIGNED AND SEALED AS IT IS REQUIRED TO | | | DEMONSTRATE CODE COMPLIANCE. SEE FS481, A TITLE BLOCK | | | FOR THE ARCHITECT IS REQUIRED, INCLUDING THE | | | ARCHITECT'S PRINTED NAME AND LICENSE NUMBER, ARCHITECT | | | BUSINESS LICENSE NUMBER. THIS COMMENT APPLIES TO OTHER | | | (POSSIBLY ALL) A SHEETS. | | | | | | SEE SHEET A0.0.02; "APPLICABLE CODES" INCLUDES A | | | REFERENCE TO THE BROWARD COUNTY AMENDMENTS TO THE FFPC, | | | REVISE. | | | | | | THRESHOLD STATEMENT FOR A SHEETS LACK A REFERENCE TO | | | THE BUILDING CODE; REVISE. | | | | | | 11. OK | | | | | | 12. FROM FIRST REVIEW: IF CIVIL SHEETS ARE USED TO SHOW | | | COMPLIANCE WITH FLORIDA BUILDING CODE, THE ADVANCED | | | BUILDING CODE COURSE IS REQUIRED FOR THE ENGINEER, | | | FS471.0195. | | | | | | 2ND REVIEW, NOT CLEAR IF THIS IS REQUIRED AS COMMENT #5 | | | WAS NOT ADDRESSED. | | | | | | FROM FIRST REVIEW: THE DBPR WEBSITE | | | (WWW.MYFLORIDALICENSE.COM) DOES NOT SHOW THAT JORGE | | | REYES, PE HAS TAKEN THE ADVANCED BUILDING CODE COURSE, | | | PLEASE ADDRESS. | | | | | | 2ND REVIEW, NOT CLEAR HOW THIS WAS ADDRESSED. AN EMAIL | | | WAS SENT TO MR. REYES ON 6/6. | | | | | | 13. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | | | | E. ENERGY CALCS WERE NOT THOROUGHLY REVIEWED. WHEN | | | RESUBMITTING THE BUILDING, ADDRESS THE FOLLOWING: | | | WATER HEATER COMPLIANCE IS BLANK | | | NO DOORS SHOWN | | | CHECK ALL | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-07 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2017-04-13 09:24:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | FROM PREVIOUS LIST (RENUMBERED): | | | | | | 1. 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 2ND REVIEW, UNABLE TO LOCATE. | | | | | | 2. THRESHOLD BLDG., REQUIRED STATEMENT: FS553.79(7)(D), | | | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRESAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND CHAPTER | | | 633. | | | | | | 2ND REVIEW, I WAS UNABLE TO LOCATE THIS STATEMENT ON | | | THE ENGINEER'S PLANS. | | | STATEMENT WAS ON AN A SHEET BUT NOT CLEAR WHO IS | | | SIGNING THAT SHEET (SEE OTHER COMMENT REGARDING TITLE | | | BLOCK), STATEMENT NOT CONSISTENT WITH FLORIDA STATUTE | | | (LACKS REFERENCE TO BUILDING CODES). | | | | | | SEE ALSO THRESHOLD REVIEW FOR ADDITIONAL REQUIREMENTS | | | (SI AGREEMENT, RESUMES, ETC.). | | | | | | 3. SOIL BEARING VALUES. THE TEST BY UNIVERSAL | | | ENGINEERING SCIENCES REFERENCES THE TEST IS PRELIMINARY | | | GEOTECHNICAL ENGINEERING REPORT BANYAN CAY- HOTEL | | | PLEASE NOTE THE BORING SAMPLES TAKEN CH-1 AND CH-2 ARE | | | SHOWN FOR THE CLUBHOUSE, THIS SOILS REPORT HAS NO | | | BORINGS SHOWN IN THE REPORT FOR THE HOTEL. NOTE FOR THE | | | TENNIS CLUB CENTER UP TO 6 FEET OF MUCK WAS ENCOUNTERED | | | WITHIN THE BUILDING FOOTPRINT. PLEASE COMPLY WITH: 2014 | | | FBC-B 1803.3 BASIS OF INVESTIGATION. | | | SOIL CLASSIFICATION SHALL BE BASED ON OBSERVATION AND | | | ANY NECESSARY TESTS OF THE MATERIALS DISCLOSED BY | | | BORINGS, TEST PITS OR OTHER SUBSURFACE EXPLORATION MADE | | | IN APPROPRIATE LOCATIONS. ADDITIONAL STUDIES SHALL BE | | | MADE AS NECESSARY TO EVALUATE SLOPE STABILITY, SOIL | | | STRENGTH, POSITION AND ADEQUACY OF LOAD-BEARING SOILS, | | | THE EFFECT OF MOISTURE VARIATION ON SOIL-BEARING | | | CAPACITY, COMPRESSIBILITY, LIQUEFACTION AND | | | EXPANSIVENESS. | | | | | | 2ND REVIEW, NOT ADDRESSED. PROVIDE A CURRENT REPORT. | | | HAVE SEOR INCORPORATE A SPECIFIC REFERENCE TO THE | | | UPDATED SOILS REPORT ON THE PLAN, OR PROVIDE A SHOP | | | DRAWING REVIEW OF THE SOILS REPORT. | | | | | | 4. SEE SIGNATURE REVIEW. | | | | | | 5. 2ND REVIEW, SET BACK/ SEPARATION FROM PROPOSED | | | BUILDING TO PROPERTY LINE(S) AND TO ASSUMED PROPERTY | | | LINES IS REQUIRED, FBC B 705.3. DEPENDING ON THE | | | LOCATION OF THE PROPERTY LINES AND/OR ASSUMED PROPERTY | | | LINES, INFORMATION REGARDING AFFECTED BUILDINGS OR | | | PROPOSED BUILDINGS MAY ALSO BE REQUIRED. | | | | | | A NOTE ON THE PLANS STATES THAT THIS BUILDING IS OVER | | | 30 FEET FROM OTHER BUILDINGS AND/OR LOT LINES. IT IS | | | NOT CLEAR WHERE THE PROPERTY LINES ARE LOCATED. | | | DISTANCE BETWEEN BUILDINGS NOT CLEAR (FOR INSTANCE - | | | PROPOSED HOTEL TO BUILDING 11 ON SHEET C2, PROPOSED | | | HOTEL TO PARKING GARAGE, HOTEL TO CLUBHOUSE), LOCATION | | | OF ASSUMED PROPERTY LINE(S) NOT CLEAR. | | | | | | 6. FROM PREVIOUS LIST: SHEET 019-S-4.06 THE PLANS | | | INDICATE PRESSURES FOR THE ROOF ZONES 1-3 AND OVERHANGS | | | ZONES 6&7. PRESSURES APPEAR TO BE LOW, UNKNOWNS, SLOPE | | | AND MEAN ROOF HEIGHT. TABLE 1609.7(2) ADJUSTMENT | | | FACTORS FOR HEIGHT & EXPOSURE. PROVIDE THE MEAN ROOF | | | HEIGHT FOR THE BUILDING. THE SAME ISSUE FOR THE WINDOW | | | AND DOOR SIZES AND ASSOCIATED PRESSURES (ZONES 4 & 5). | | | | | | COMMENT NOT ENTIRELY ADDRESSED. SLOPE WAS PROVIDED AS | | | 4:12 MANSARD. THE ROOF PLAN ON S4.06 APPEARS TO SHOW | | | BOTH PITCHED ROOF AND FLAT ROOF AREAS. THE C&C WIND | | | DESIGN PRESSURES ON THE TWO CHARTS ARE TOO LOW, EVEN | | | FOR THE PITCHED ROOFS. ENGINEER'S INTENT NOT CLEAR; ARE | | | ALL ROOFS C&C TO MEET THE SAME DESIGN PRESSURES FOR | | | FLAT, MANSARD, AND PITCHED? IF THIS IS THE CASE, C&C | | | ROOF PRESSURES TO BE "WORST CASE" CRITERIA (FLAT). | | | | | | SOME OF THE WALL C&C DESIGN PRESSURES SPECIFIED ALSO | | | APPEAR TOO LOW (SEE 1ST REVIEW). EITHER CORRECT DESIGN | | | PRESSURES OR INCORPORATE THE CALCULATIONS FOR THE C&C | | | DPS INTO THE PLAN. IF THE PRESSURES ARE NOT INCREASED, | | | SEND THE CALCULATIONS VIA EMAIL PRIOR TO RESUBMITTAL | | | FOR PRELIMINARY REVIEW. IF THE PRESSURES ARE REVISED TO | | | BE CONSISTENT WITH THE TABLES IN FBC CHAPTER 16 OR | | | ASCE7-10, CALCULATIONS ARE NOT REQUIRED. | | | | | | 7. SEE SIGNATURE REVIEW. | | | | | | 8. SEE IMPACT FEE REVIEW. | | | | | | NEW COMMENTS: | | | | | | 9. S0.01, A LINE OF TEXT (BETWEEN LINTELS AND ROOF | | | DECK) IS NOT LEGIBLE, FBC 107, PROVIDE LEGIBLE TEXT. | | | | | | 10. FS471, FS481, ARCHITECTS AND ENGINEERS HAVE | | | REQUIREMENTS TO HAVE A TITLE BLOCK ON EACH SHEET WHICH | | | INCLUDES THE PRINTED NAME AND LICENSE NUMBER, COMPANY | | | LICENSE NUMBER (AS WELL AS OTHER INFORMATION). | | | | | | STRUCTURAL ENGINEER OF RECORD HAS A COMPLIANT TITLE | | | BLOCK ON ALL S SHEETS. HOWEVER, REGARDING THE | | | ARCHITECTURAL SHEETS, IT NOT CLEAR WHO IS SEALING THESE | | | SHEETS. THE ARCHITECTURAL SHEETS LACK A TITLE BLOCK. | | | THERE IS A BAR WITH ALL OF THE DESIGN PROFESSIONALS. | | | THE ENGINEER'S NAME IS IN THE "SEAL" BLOCK. REVISE | | | ARCHITECTURAL SHEETS TO INCLUDE ALL INFORMATION | | | REQUIRED BY FAC61G16, FS481. | | | | | | 11. CIVIL SHEETS USE NGVD29 VERTICAL DATUM. A0.0.02 | | | PROPOSES A FINISHED FLOOR OF 22'0' NAVD88. THERE IS A | | | CONFLICT OF APPROXIMATELY 18"; REVISE TO BE CONSISTENT. | | | NGVD29 IS RECOMMENDED AT THIS TIME. | | | | | | 12. IF CIVIL SHEETS ARE USED TO SHOW COMPLIANCE WITH | | | FLORIDA BUILDING CODE, THE ADVANCED BUILDING CODE | | | COURSE IS REQUIRED FOR THE ENGINEER, FS471.0195. | | | | | | THE DBPR WEBSITE (WWW.MYFLORIDALICENSE.COM) DOES NOT | | | SHOW THAT JORGE REYES, PE HAS TAKEN THE ADVANCED | | | BUILDING CODE COURSE, PLEASE ADDRESS. | | | | | | 13. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. COMPLIANCE WITH ART IN PUBLIC PLACES ORDINANCE | | | 78-123 REQUIRED: MS. SYBILLE WELTER, 561-822-1515, | | | [email protected]. MS. WELTER WILL ADVISE VIA EMAIL WHEN | | | THIS IS COMPLETE. | | | | | | B. FBC 110.3.7.4.3 SHORING AND RESHORE ENGINEERING TO | | | BE SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | FAILURE TO SUBMIT SHORING/RESHORE ENGINEERING TIMELY | | | WILL RESULT IN A STOP WORK ORDER. AN ENGINEERED | | | GUARDRAIL DETAIL (CONSTRUCTION IN PROGRESS) IS ALSO | | | REQUIRED PRIOR TO INSTALLATION. | | | | | | C. FBC 105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL | | | OF THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE | | | CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A | | | BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS | | | FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN | | | SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION | | | OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED | | | AT THE HOLDER?S OWN RISK WITH THE BUILDING OPERATION | | | AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE | | | STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED | | | TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS | | | PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL | | | OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST | | | BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. | | | | | | D. THE LIFE SAFETY SHEETS WERE NOT THOROUGHLY REVIEWED. | | | THIS WILL BE REVIEWED UNDER THE BUILDING PERMIT | | | APPLICATION; FOUNDATION PERMIT WILL BE ISSUED AT | | | APPLICANT'S RISK. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-02-09 |
Time |
06:02 |
Sent To |
|
|
| Notes |
| 2017-02-09 08:39:40 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: THURS. FEB. 09/ 2017 | | | ACTION: DENIED | | | | | | 1) THE ADDRESS OF 3200 N. CONGRESS IS A PRELIMINARY | | | SITE ADDRESS FOR THE WHOLE DEVELOPMENT. A SEPARATE | | | ADDRESS WILL BE ASSIGNED TO EACH NEW PROPERTY AS THE | | | PARCEL IS BROKE UP INTO INDUVIAL LOTS. | | | ADDRESSING: CITY MUNI CODE SEC.78-6 (1-7). | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. | | | | | | 2) ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH | | | ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES | | | TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH | | | THE PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND | | | THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS | | | ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 3) THE COST OF THE PROJECT WILL BE EVALUATED UNDER THE | | | BUILDING PERMIT. PERMIT FEES/ PLAN REVIEW: | | | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT | | | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, | | | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS | | | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID | | | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE | | | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. | | | | | | 4) THE PLANS AND SOILS REPORT INDICATES THIS IS TO BE A | | | 4 STORY HOTEL. THIS PROJECT IS IDENTIFIED AS A | | | THRESHOLD BUILDING / FL S. S. 553.71(7) ?THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 4A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 4B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. | | | | | | FORMS E-MAILED TO: [email protected] THURS. | | | FEB. 09/2017 08:38 AM | | | | | | 4C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 4D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | 4E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 4F) FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, PLEASE | | | E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING ISSUED, | | | THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE APPROVED | | | AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, | | | TWO SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) | | | FOR THE THRESHOLD INSPECTOR, THE OTHER FOR THE MEP | | | INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE IN BLACK | | | & WHITE.. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING SPECIAL INSPECTORS. | | | | | | 4G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | | | | 4H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | 4I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | | WALLS AND CEILINGS. | | | | | | 5A) SOIL BEARING VALUES. THE TEST BY UNIVERSAL | | | ENGINEERING SCIENCES REFERENCES THE TEST IS PRELIMINARY | | | GEOTECHNICAL ENGINEERING REPORT BANYAN CAY- HOTEL | | | PLEASE NOTE THE BORING SAMPLES TAKEN CH-1 AND CH-2 ARE | | | SHOWN FOR THE CLUBHOUSE, THIS SOILS REPORT HAS NO | | | BORINGS SHOWN IN THE REPORT FOR THE HOTEL. NOTE FOR THE | | | TENNIS CLUB CENTER UP TO 6 FEET OF MUCK WAS ENCOUNTERED | | | WITHIN THE BUILDING FOOTPRINT. PLEASE COMPLY WITH: 2014 | | | FBC-B 1803.3 BASIS OF INVESTIGATION. | | | SOIL CLASSIFICATION SHALL BE BASED ON OBSERVATION AND | | | ANY NECESSARY TESTS OF THE MATERIALS DISCLOSED BY | | | BORINGS, TEST PITS OR OTHER SUBSURFACE EXPLORATION MADE | | | IN APPROPRIATE LOCATIONS. ADDITIONAL STUDIES SHALL BE | | | MADE AS NECESSARY TO EVALUATE SLOPE STABILITY, SOIL | | | STRENGTH, POSITION AND ADEQUACY OF LOAD-BEARING SOILS, | | | THE EFFECT OF MOISTURE VARIATION ON SOIL-BEARING | | | CAPACITY, COMPRESSIBILITY, LIQUEFACTION AND | | | EXPANSIVENESS. | | | | | | 5B) SOILS REPORT IS NOT DIGITALLY SIGNED. 61G15-23.005 | | | PROCEDURES FOR SIGNING AND SEALING ELECTRONICALLY | | | TRANSMITTED PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS. | | | | | | 6A) THIS PERMIT IS FOR A FOUNDATION BUT TO DATE THERE | | | HAS BEEN NO SURVEY SUBMITTED NOR SITE PLAN SHOWING THE | | | LOCATION OF THE BUILDING ON THE PROPERTY, CLOSENESS TO | | | PROPERTY LINE, EASEMENTS, OR IDENTIFICATION OF TYPE OF | | | FLOOD ZONE, AND FINISH FLOOR ELEVATION IN NGVD. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: 107.3.5.1.1 BUILDING | | | 1. SITE REQUIREMENTS: | | | PARKING | | | FIRE ACCESS | | | VEHICLE LOADING | | | DRIVING/TURNING RADIUS | | | FIRE HYDRANT/WATER SUPPLY/POST INDICATOR VALVE (PIV) | | | SET BACK/SEPARATION (ASSUMED PROPERTY LINES) | | | LOCATION OF SPECIFIC TANKS, WATER LINES AND SEWER LINES | | | FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN FLOOD | | | ELEVATIONS | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES AND, AS APPLICABLE, | | | FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN FLOOD | | | ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN | | | ACCURATE BOUNDARY LINE SURVEY. | | | | | | 6B) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: 107.3.5.1.1 BUILDING | | | 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | | (SEE TABLE 503). | | | 5. BUILDING FIRE SPRINKLERED OR NOT: FIRE SUPPRESSION | | | SYSTEMS SHALL INCLUDE: | | | SCHEMATIC FIRE SPRINKLERS | | | STANDPIPES | | | PRE-ENGINEERED SYSTEMS | | | RISER DIAGRAM | | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | CONSTRUCTION REQUIREMENTS | | | HORIZONTAL EXITS/EXIT PASSAGEWAYS | | | | | | 7) A FOUNDATION PERMIT IS NEVER ISSUED UNTIL THE | | | BUILDING PERMIT IS APPLIED FOR, AND OR ENOUGH | | | INFORMATION IS GIVEN IN THE FLOOR PLAN LAYOUT AND | | | ELEVATIONS (SUBMIT ARCHITECTURAL FLOOR PLANS AND | | | ELEVATIONS) THAT THE BUILDING DOESN?T HAVE MAJOR FLAWS | | | IN THE DESIGN AND PERMITS NOT ATTAINABLE TO COMPLETE | | | THE PROJECT. EVEN WITH THE ISSUANCE OF A FOUNDATION | | | PERMIT IT IS AT THE PERMIT HOLDERS OWN RISK. | | | 107.3.3 PHASED APPROVAL. THE BUILDING OFFICIAL IS | | | AUTHORIZED TO ISSUE A PERMIT FOR THE CONSTRUCTION OF | | | FOUNDATIONS OR ANY OTHER PART OF A BUILDING OR | | | STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS FOR THE | | | WHOLE BUILDING OR STRUCTURE HAVE BEEN SUBMITTED, | | | PROVIDED THAT ADEQUATE INFORMATION AND DETAILED | | | STATEMENTS HAVE BEEN FILED COMPLYING WITH PERTINENT | | | REQUIREMENTS OF THIS CODE. THE HOLDER OF SUCH PERMIT | | | FOR THE FOUNDATION OR OTHER PARTS OF A BUILDING OR | | | STRUCTURE SHALL PROCEED AT THE HOLDER?S OWN RISK WITH | | | THE BUILDING OPERATION AND WITHOUT ASSURANCE THAT A | | | PERMIT FOR THE ENTIRE STRUCTURE WILL BE GRANTED. | | | | | | 8A) SHEET 019-S-4.06 THE PLANS INDICATE PRESSURES FOR | | | COMPONENTS AND CLADDING. THERE IS A DISCREPANCY IN | | | PLANS. SHEET 001-S-0.00 INDICATES VULT WIND SPEED TO BE | | | 170 MPH (3-SECOND GUST), VASD TO BE 132 (3-SECOND | | | GUST). SHEET 019-S-4.06 INDICATES WIND AS VULT= 175 | | | MPH, 3 SECOND GUST AND VASD = 136 MPH 3 SECOND GUST. | | | DISCREPANCY IN PLANS 107.2.1.3 ADDITIONAL INFORMATION | | | IS REQUIRED. | | | | | | 8B) SHEET 001-S-0.00 PROVIDES A PARTIAL WIND DESIGN, | | | THE DESIGN DOES NOT PROVIDE AT WHAT HEIGHT THE MEAN | | | ROOF HEIGHT HAS BEEN TAKEN. 2014 FBC-B 3. WIND | | | EXPOSURE. APPLICABLE WIND DIRECTION IF MORE THAN ONE | | | WIND EXPOSURE IS UTILIZED) SHEET 019-S-4.06 THE PLANS | | | INDICATE PRESSURES 9) ) SHEET 019-S-4.06 THE PLANS | | | INDICATE PRESSURES FOR THE ROOF ZONES 1-3 AND OVERHANGS | | | ZONES 6&7. PRESSURES APPEAR TO BE LOW, UNKNOWNS, SLOPE | | | AND MEAN ROOF HEIGHT. TABLE 1609.7(2) ADJUSTMENT | | | FACTORS FOR HEIGHT & EXPOSURE. PROVIDE THE MEAN ROOF | | | HEIGHT FOR THE BUILDING. THE SAME ISSUE FOR THE WINDOW | | | AND DOOR SIZES AND ASSOCIATED PRESSURES (ZONES 4 & 5). | | | | | | 9) STRUCTURAL SHEETS, THERE IS NO DIGITAL SIGNATURE | | | FROM THE ENGINEER OF RECORD. | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS. | | | | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | | SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE | | | OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-03-23 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-23 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-23 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-02-14 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-14 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-14 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2017-02-14 09:10:42 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1- PLEASE PROVIDE AN ELECTRICAL ONE-LINE DIAGRAM | | | REFLECTING THE GROUNDING ELECTRODE CONDUCTOR SIZE IN | | | CONNECTION WITH THE FOUNDATION FOOTER. ALSO REFLECT ANY | | | ELECTRICAL TO BE INSTALLED IN FOUNDATION, EXAMPLE FLOOR | | | BOXES, NOTES ON RACEWAY FROM UTILITY(POWER AND COMM) | | | ROUTES ETC, FBC 107.3.5 | | | | | | VAL PEREZ | | | *6717 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2017-02-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-02-24 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-02-24 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2017-05-04 11:13:33 | FORMAL SUBMITTAL OF THE DEVELOPMENT PERMIT IS REQUIRED | | | WITH CWPB ENGINEERING DEPT. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | | | | | | 2017-02-24 17:15:55 | PER MGONZALES EMAIL OF 2/24/17 ENGINEERING REVIEW WILL | | | BE DONE UNDER FORMAL ENGINEERING SUBMITTAL ONLY. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-03-15 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-03-15 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2018-03-15 14:27:13 | ******** FOUNDATION ONLY******** | | | | | | APPROVED FIRE DEPARTMENT ACCESS AND APPROVED WATER | | | SUPPLY REQUIRED PRIOR TO VERTICAL CONSTRUCTION. | | | | | | | | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | | JURISDICTION. | | | | | | TEMPORARY CONSTRUCTION TRAILERS OR MODULAR BUILDINGS | | | WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | | FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-03-22 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-03-22 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-03-22 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2017-03-22 16:17:35 | *****FOUNDATION ONLY***** | | | | | | APPROVED FIRE DEPARTMENT ACCESS AND APPROVED WATER | | | SUPPLY NEEDED PRIOR TO VERTICAL CONSTRUCTION. | | | | | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | | JURISDICTION | | | TEMPORARY CONSTRUCTION TRAILERS OR MODULAR BUILDINGS | | | WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | | FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-02-15 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-02-15 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-02-15 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2017-02-15 07:22:35 | *****FOUNDATION ONLY***** | | | | | | APPROVED FIRE DEPARTMENT ACCESS AND APPROVED WATER | | | SUPPLY NEEDED PRIOR TO VERTICAL CONSTRUCTION. | | | | | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | | JURISDICTION | | | TEMPORARY CONSTRUCTION TRAILERS OR MODULAR BUILDINGS | | | WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | | FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-11 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-11 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-18 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-02 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-12 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-16 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-20 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-07-20 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-01 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-04-14 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-03-21 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-02-27 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-01-30 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-05 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-05 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2018-11-05 13:09:23 | MU-2017-015390-0000 | | | HARD COPY WITH COUNTY STAMP BROUGHT IN ON 11/5/18 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-18 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-18 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2018-07-18 12:40:07 | IMPACT FEES TO BE COLLECTED PRIOR TO VERTICAL PERMIT | | | ISSUANCE |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-09 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-09 |
Time |
06:02 |
Sent To |
|
|
| Notes |
| 2017-02-09 08:40:28 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-06 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-06 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-13 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-13 |
Time |
17:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-03-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-03-30 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-30 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2017-03-30 16:28:18 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE FIXTURE COUNT BREAKDOWN BASED ON | | | OCCUPANT LOAD OF FIRST FLOOR. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. SHT. P-0.0.00 ON THE TABLE FOR HORIZONTAL PIPE | | | HANGERS THE DISTANCE FOR CPVC SHALL BE 3' . PER FBC PL | | | TABLE 308.5 | | | | | | 3. SHT. P-1.1.00 THE GREASE TRAP CALCULATION THAT WERE | | | USED ARE FOR ESTABLISHMENTS WITH COMMERCIAL KITCHENS | | | THIS APPLICATION SHALL BE FOR RESTAURANTS ITS A | | | DIFFERENT CALCULATION USING NUMBER OF SEATS AND HOURS | | | OF OPERATION. PER FBC PL 1003.2 | | | | | | 4. LABEL ALL FIXTURES ON RISER DIAGRAMS. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 5. P-3.0.02 THE BRANCH DRAIN FOR THE FLOOR DRAIN AND | | | LAVS IN MENS BATHROOM #1149 SHALL NOT ROLL UP OVER THE | | | 8" BUILDINGG DRAIN YOU CAN ROLL THE BRANCH DRAIN FOR | | | THE WHOLE GAIN BATHROOM UP TO CLEAR THE BUILDIN DRAIN | | | MAIN TRUNK LINE. PER FBC PL 901.2.1 | | | | | | 6. SOME OF THE SOIL STACK ARE NOTE SIZED OR LABELED | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. PLEASE PROVIDE KITCHEN EQUIPMENT PLAN AND SCHEDULE | | | FOR #1129, #1118 AND #1119. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 8. PROVIDE PLUMBING FLOOR PLAN WITH THE SOIL STACKS | | | LABELED TO MATCH RISER DIAGRAM. FOR FIRST FLOOR. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 9. HORIZONTAL DRY VENTS ARE PROHIBITED BELOW FLOOD | | | LEVEL RIM OF FIXTURES I FOUND A FEW IN THE KITCHEN AND | | | SOME OTHER AREAS BUT IT WAS DIFFICULT TO LOCATE EXACT | | | LOCATION DUE TO NOT HAVING A PLUMBING FLOOR PLAN PLEASE | | | CHECK FOR NEXT REVIEW. PER WPB AMEND TO FBC 107.2.1 | | | | | | 10. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS. PER FBC | | | PL 1002.41002.41002.4 | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-10 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-10 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2017-02-10 13:35:10 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | 1. WILL THERE BE ANY PLUMBING UNDER THIS FOUNDATION | | | PERMIT IF SO PLEASE PROVIDE DRAWING CLEARLY INDECATING | | | WHAT PLUMBING WILL BE DONE OR PROVIDE NOTE ON PLAN | | | INDICATING NO PLUMBING. PER WPB AMEND TO FBC 107.2.1 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
P |
Date |
2018-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-18 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-18 |
Time |
18:25 |
Sent To |
|
|
| Notes |
| 2018-07-18 18:28:02 | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - ??? JORGE E. REYES, PE OR HECTOR E. | | | GONZALEZ? | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | | | | 1. ARCHITECTURAL, ELECTRICAL, PLUMBING, STRUCTURAL | | | SHEETS OK (NEW S SHEETS PROVIDED VIA EMAIL) | | | | | | 2. THRESHOLD DOCS (SI AGREEMENT, RESUMES) - RECEIVED | | | PAPER, ROUTED TO KEN CONRAD. | | | | | | 3. SOILS REPORT - OK (RECEIVED PAPER ORIGINAL). | | | | | | 4. CIVIL PAGES - OK (RECEIVED PAPER ORIGINAL) | | | | | | 5. SITE EGRESS PLAN - OK (RECEIVED PAPER ORIGINAL) | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
F |
Date |
2018-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-11 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-07 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2018-07-11 18:06:52 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - ??? JORGE E. REYES, PE OR HECTOR E. | | | GONZALEZ? | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | | | | 1. ARCHITECTURAL (EXCEPT AS NOTED BELOW), ELECTRICAL, | | | PLUMBING SHEETS OK. ANY NEW SHEETS SUBMITTED IN NEXT | | | REVIEW CYCLE REQUIRE REVIEW. | | | | | | NEW STRUCTURAL PAGES COMPLETELY REPLACED ALL PREVIOUS | | | STRUCTURAL PAGES AND ARE NOT DIGITALLY SIGNED AND | | | SEALED. | | | | | | (ADVISED APPLICANT VIA EMAIL) PLEASE EITHER: | | | | | | UPLOAD INDIVIDUAL ORIGINAL SIGNED AND SEALED PAGES | | | (NAMED SAME AS THE PAGES WHICH ARE NOT S&S) IN THE | | | "DRAWINGS" FOLDER, OR | | | | | | PROVIDE ONE PDF OF ALL STRUCTURAL SHEETS WHICH IS | | | DIGITALLY SIGNED AND SEALED; SEND TO ME VIA EMAIL AND | | | CC [email protected], [email protected] | | | | | | 2. THRESHOLD DOCS (SI AGREEMENT, RESUMES) - RECEIVED | | | PAPER, ROUTED TO KEN CONRAD. | | | | | | 3. SOILS REPORT - OK (RECEIVED PAPER ORIGINAL). | | | | | | 4. CIVIL PAGES - OK (RECEIVED PAPER ORIGINAL) | | | | | | 5. SITE EGRESS PLAN IS NOT SIGNED AND SEALED, FS481. | | | | | | 6. DOCUMENT SP-2 05-22-17 WITH SETBACKS.PDF IS | | | DIGITALLY SIGNED AND SEALED BY A LANDSCAPE ARCHITECT. | | | | | | 7. OK | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-13 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2018-05-13 08:38:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - ??? JORGE E. REYES, PE OR HECTOR E. | | | GONZALEZ? | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | | | | 1. STRUCTURAL, ARCHITECTURAL (EXCEPT AS NOTED BELOW), | | | ELECTRICAL, PLUMBING SHEETS OK. ANY NEW SHEETS | | | SUBMITTED IN NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. THRESHOLD INSPECTION PLAN OK (IN SUPPORTING DOCS | | | FOLDER). | | | | | | 3. SOILS REPORT IS NOT DIGITALLY SIGNED AND SEALED; | | | PROVIDE ONE PAPER ORIGINAL OR UPLOAD DIGITALLY SIGNED | | | AND SEALED DOCUMENT IN NEXT REVIEW. | | | | | | 4. CIVIL PAGES ARE NOT DIGITALLY SIGNED AND SEALED; | | | PROVIDE ONE PAPER ORIGINAL OR UPLOAD DIGITALLY SIGNED | | | AND SEALED DOCUMENTS IN NEXT REVIEW. | | | | | | 5. SITE EGRESS PLAN IS NOT SIGNED AND SEALED, FS481. | | | | | | 6. DOCUMENT SP-2 05-22-17 WITH SETBACKS.PDF IS | | | DIGITALLY SIGNED AND SEALED BY A LANDSCAPE ARCHITECT. | | | | | | 7. AS ADVISED IN OTHER REVIEWS, THE LICENSE NUMBERS FOR | | | THE BUSINESS FOR ARCHITECT AND ENGINEER ARE REQUIRED TO | | | BE ON THE TITLE BLOCK, FS471, FS481 (ADACHE AND TLC). | | | PLEASE UPDATE ALL SHEETS BUT ONLY UPLOAD SHEETS WHICH | | | CHANGE DUE TO CODE RELATED COMMENTS. YOU CAN FIND THE | | | BUSINESS LICENSE NUMBERS AT WWW.MYFLORIDALICENSE.COM. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-02 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-02 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2018-04-02 17:05:28 | S SHEETS NOT SIGNED AND SEALED | | | NEED SIGNED & SEALED SOILS REPORT (PETER READ, PE) | | | | | | | | | STRUCTURAL CALCS OK | | | THRESHOLD INSPECTION PLAN OK | | | | | | 6/16 - HARD COPY CIVIL DRAWINGS IN LIBRARY | | | PLUMB PAGES OK GPJ 6/13/17 | | | ELEC SHEETS OK - SH 1/10/18 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2018-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-10 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-10 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2018-01-10 07:10:23 | 6/16 - HARD COPY CIVIL DRAWINGS IN LIBRARY | | | PLUMB PAGES OK GPJ 6/13/17 | | | ELEC SHEETS OK - SH 1/10/18 | | | | | | A, S SHEETS NOT SIGNED AND SEALED | | | NEED SIGNED & SEALED SOILS REPORT (PETER READ, PE) | | | STRUCTURAL CALCS OK | | | THRESHOLD INSPECTION PLAN OK | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-20 |
Time |
06:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-28 |
Time |
06:19 |
Sent To |
|
|
| Notes |
| 2017-06-16 12:52:31 | 6/16 - HARD COPY CIVIL DRAWINGS IN LIBRARY | | 2017-06-13 17:11:30 | PLUMB PAGES OK GPJ 6/13/17 | | 2017-06-02 14:38:51 | A, C, S SHEETS NOT SIGNED AND SEALED | | | SITE PLAN OK | | | | | | NEED SIGNED & SEALED SOILS REPORT (PETER READ, PE) | | | STRUCTURAL CALCS OK | | | THRESHOLD INSPECTION PLAN OK | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-11 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-11 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2017-04-05 07:41:53 | NEED SIGNED & SEALED SOILS REPORT (PETER READ, PE) | | | A, S, C SHEETS NOT SIGNED & SEALED (SEE PLAN REVIEW | | | NOTES) | | | | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
7 |
Status |
P |
Date |
2018-09-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-07 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-07 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2018-09-07 11:15:30 | 17010911 SI AGREEMENT SIGNED BY: | | | ANDREW SULLIVAN, PE SI, MCNAMARA SALVIA | | | CHAD CASSETT, PE - INSPECTOR | | | SERGIO GONZALEZ, PE - INSPECTOR | | | CONTRACTOR - DON PERRY, JACOB ERECTING & CONSTRUCTION | | | LLC | | | OWNER - DOMENIC GIATTO | | | | | | PROJECT INFORMATION: | | | | | | BANYAN CAY FOUR STORY HOTEL **FOUNDATION ONLY** | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - JORGE E. REYES, PE54904 | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
6 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-07-20 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-07 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2018-07-07 18:15:22 | 17010911 SI AGREEMENT SIGNED BY: | | | ANDREW SULLIVAN, PE SI, MCNAMARA SALVIA | | | CHAD CASSETT, PE - INSPECTOR (WILL ADD SERGIO GONZALEZ, | | | PE AT FUTURE DATE) | | | CONTRACTOR - DON PERRY, JACOB ERECTING & CONSTRUCTION | | | LLC | | | OWNER - DOMENIC GIATTO | | | | | | PROJECT INFORMATION: | | | | | | BANYAN CAY FOUR STORY HOTEL **FOUNDATION ONLY** | | | ***THRESHOLD BUILDING***, POST TENSION 6"-8" SLABS, FRT | | | TRUSSES, TYPE IIA | | | ARCHITECT - ADACHE GROUP ARCHITECTS, DANIEL E. ADACHE | | | AR7073 | | | ENGINEER - MUE ENGINEERS, INC (29348), MARCUS O. | | | UNTERWEGER, PE63860 | | | MEP - TLC ENGINEERING | | | MECHANICAL - JORGE E. REYES, PE54904 | | | ELECTRICAL - RALPH BAEZA, PE42641 | | | PLUMBING - JORGE E. REYES, PE54904 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
5 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-13 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2018-05-13 08:40:42 | NO NEW DOCUMENTS PROVIDED; SI AGREEMENT WAS UPLOADED ON | | | 6/1/2017. | | | | | | SEE PREVIOUS REVIEW | | | | | | AS THIS AGREEMENT WAS NOT COMPLETED PRIOR TO | | | IMPLEMENTATION OF AN UPDATED AGREEMENT, PLEASE COMPLETE | | | THE NEW SI AGREEMENT. SEND A REQUEST FOR THE DOCUMENT | | | TO [email protected] | | | | | | THIS WILL BE ACCEPTED VIA EMAIL ONLY IF THE AGREEMENT | | | IS 100% COMPLETE WITH ALL SIGNATURES AND RESUMES AND | | | COPIES OF LICENSES FOR INSPECTORS | | | DUE TO TIME CONSTRAINTS, PLEASE DO NOT SEND AN | | | INCOMPLETE DOCUMENT. REVIEWING VIA EMAIL IS A COURTESY | | | - IF MULTIPLE INCOMPLETE DOCUMENTS ARE SUBMITTED (AS | | | HAVE BEEN IN THE PAST ON OTHER PROJECTS), THIS WILL BE | | | REVIEWED ONLY DURING A REVIEW CYCLE. | | | | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
4 |
Status |
F |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-02 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-02 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2018-04-02 17:07:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | COMMENTS FROM PREVIOUS REVIEW (NO NEW DOCUMENTS WERE | | | UPLOADED INTO PROJECTDOX) | | | | | | 1. THE INSPECTOR AGREEMENT IS NOT COMPLETE; ALL | | | SIGNATURES ARE REQUIRED. WHEN ALL SIGNATURES ARE | | | PROVIDED, ALONG WITH RESUMES, THE PACKAGE WILL BE | | | FORWARDED TO KEN CONRAD FOR REVIEW. | | | | | | A COMPLETE THRESHOLD PACKAGE MAY BE SENT TO ME VIA | | | EMAIL. | | | | | | 2. NAME OF THE SI INSPECTION COMPANY IS NOT LEGIBLE. | | | | | | 3. PLEASE ADVISE; WHO WILL BE THE ON- SITE | | | INSPECTOR(S)? IF ONLY MR. RAJRAJBHANDARI IS TO BE AN ON | | | SITE INSPECTOR, IT IS RECOMMENDED THAT YOU HAVE AN | | | ALTERNATE IN THE EVENT THAT INDIVIDUAL IS UNAVAILABLE | | | (ILLNESS, VACATION, OR OTHER REASON). ONLY INSPECTORS | | | WHO HAVE BEEN APPROVED AND WHO HAVE SIGNED THE | | | AGREEMENT WILL BE PERMITTED. SOME COMPANIES HAVE ALL OF | | | THEIR EMPLOYEES SIGN THE AGREEMENT; ONE INSPECTOR TO BE | | | PRIMARY, THE OTHERS TO BE BACKUP. | | | | | | 4. SEE THRESHOLD INSPECTION PLAN AND REQUIREMENTS FOR | | | THE SPECIAL INSPECTOR. THE RESUMES SHOULD REFLECT THE | | | EXPERIENCE REQUIRED AND SHOULD BE REVIEWED BY ARCHITECT | | | AND ENGINEER OF RECORD. | | | | | | 5. CLARIFY; WHO WILL MONITOR THE VIBRO FLOTATION? | | | | | | 6. CLARIFY; THE DULY AUTHORIZED REPRESENTATIVE MAY NOT | | | BE THE SAME PERSON PERFORMING ANY MATERIAL TESTING PER | | | THRESHOLD INSPECTION PLAN; ACKNOWLEDGE INSPECTOR'S | | | UNDERSTANDING OF THIS REQUIREMENT. | | | | | | 7. SEE BUILDING REVIEW; THRESHOLD STATEMENT FOR A | | | SHEETS LACK REFERENCE TO THE BUILDING CODE, SEE FS553. | | | | | | | | | NOTES: | | | THRESHOLD INSPECTION PLAN (SUPPORTING DOCUMENTS) - OK | | | THRESHOLD STATEMENT ON ALL S SHEETS - OK | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
F |
Date |
2018-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-10 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-10 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2018-01-10 07:13:22 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | COMMENTS FROM PREVIOUS REVIEW (NO NEW DOCUMENTS WERE | | | UPLOADED INTO PROJECTDOX) | | | | | | 1. THE INSPECTOR AGREEMENT IS NOT COMPLETE; ALL | | | SIGNATURES ARE REQUIRED. WHEN ALL SIGNATURES ARE | | | PROVIDED, ALONG WITH RESUMES, THE PACKAGE WILL BE | | | FORWARDED TO KEN CONRAD FOR REVIEW. | | | | | | A COMPLETE THRESHOLD PACKAGE MAY BE SENT TO ME VIA | | | EMAIL. | | | | | | 2. NAME OF THE SI INSPECTION COMPANY IS NOT LEGIBLE. | | | | | | 3. PLEASE ADVISE; WHO WILL BE THE ON- SITE | | | INSPECTOR(S)? IF ONLY MR. RAJRAJBHANDARI IS TO BE AN ON | | | SITE INSPECTOR, IT IS RECOMMENDED THAT YOU HAVE AN | | | ALTERNATE IN THE EVENT THAT INDIVIDUAL IS UNAVAILABLE | | | (ILLNESS, VACATION, OR OTHER REASON). ONLY INSPECTORS | | | WHO HAVE BEEN APPROVED AND WHO HAVE SIGNED THE | | | AGREEMENT WILL BE PERMITTED. SOME COMPANIES HAVE ALL OF | | | THEIR EMPLOYEES SIGN THE AGREEMENT; ONE INSPECTOR TO BE | | | PRIMARY, THE OTHERS TO BE BACKUP. | | | | | | 4. SEE THRESHOLD INSPECTION PLAN AND REQUIREMENTS FOR | | | THE SPECIAL INSPECTOR. THE RESUMES SHOULD REFLECT THE | | | EXPERIENCE REQUIRED AND SHOULD BE REVIEWED BY ARCHITECT | | | AND ENGINEER OF RECORD. | | | | | | 5. CLARIFY; WHO WILL MONITOR THE VIBRO FLOTATION? | | | | | | 6. CLARIFY; THE DULY AUTHORIZED REPRESENTATIVE MAY NOT | | | BE THE SAME PERSON PERFORMING ANY MATERIAL TESTING PER | | | THRESHOLD INSPECTION PLAN; ACKNOWLEDGE INSPECTOR'S | | | UNDERSTANDING OF THIS REQUIREMENT. | | | | | | 7. SEE BUILDING REVIEW; THRESHOLD STATEMENT FOR A | | | SHEETS LACK REFERENCE TO THE BUILDING CODE, SEE FS553. | | | | | | | | | NOTES: | | | THRESHOLD INSPECTION PLAN (SUPPORTING DOCUMENTS) - OK | | | THRESHOLD STATEMENT ON ALL S SHEETS - OK | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-02 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-02 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2017-06-02 14:38:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. THE INSPECTOR AGREEMENT IS NOT COMPLETE; ALL | | | SIGNATURES ARE REQUIRED. WHEN ALL SIGNATURES ARE | | | PROVIDED, ALONG WITH RESUMES, THE PACKAGE WILL BE | | | FORWARDED TO KEN CONRAD FOR REVIEW. | | | | | | A COMPLETE THRESHOLD PACKAGE MAY BE SENT TO ME VIA | | | EMAIL. | | | | | | 2. NAME OF THE SI INSPECTION COMPANY IS NOT LEGIBLE. | | | | | | 3. PLEASE ADVISE; WHO WILL BE THE ON- SITE | | | INSPECTOR(S)? IF ONLY MR. RAJRAJBHANDARI IS TO BE AN ON | | | SITE INSPECTOR, IT IS RECOMMENDED THAT YOU HAVE AN | | | ALTERNATE IN THE EVENT THAT INDIVIDUAL IS UNAVAILABLE | | | (ILLNESS, VACATION, OR OTHER REASON). ONLY INSPECTORS | | | WHO HAVE BEEN APPROVED AND WHO HAVE SIGNED THE | | | AGREEMENT WILL BE PERMITTED. SOME COMPANIES HAVE ALL OF | | | THEIR EMPLOYEES SIGN THE AGREEMENT; ONE INSPECTOR TO BE | | | PRIMARY, THE OTHERS TO BE BACKUP. | | | | | | 4. SEE THRESHOLD INSPECTION PLAN AND REQUIREMENTS FOR | | | THE SPECIAL INSPECTOR. THE RESUMES SHOULD REFLECT THE | | | EXPERIENCE REQUIRED AND SHOULD BE REVIEWED BY ARCHITECT | | | AND ENGINEER OF RECORD. | | | | | | 5. CLARIFY; WHO WILL MONITOR THE VIBRO FLOTATION? | | | | | | 6. CLARIFY; THE DULY AUTHORIZED REPRESENTATIVE MAY NOT | | | BE THE SAME PERSON PERFORMING ANY MATERIAL TESTING PER | | | THRESHOLD INSPECTION PLAN; ACKNOWLEDGE INSPECTOR'S | | | UNDERSTANDING OF THIS REQUIREMENT. | | | | | | 7. SEE BUILDING REVIEW; THRESHOLD STATEMENT FOR A | | | SHEETS LACK REFERENCE TO THE BUILDING CODE, SEE FS553. | | | | | | | | | NOTES: | | | THRESHOLD INSPECTION PLAN (SUPPORTING DOCUMENTS) - OK | | | THRESHOLD STATEMENT ON ALL S SHEETS - OK | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2017-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-09 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-09 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2017-02-09 08:42:39 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17010911 (HOTEL FOUNDATION) | | | ADD: 3200 N. CONGRESS AVE. (ADDRESS TO BE ASSIGNED) | | | CONT: HEDRICK BROTHERS | | | TEL: 561-689-8880 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: THURS. FEB. 09/ 2017 | | | ACTION: DENIED | | | 1) THE PLANS AND SOILS REPORT INDICATES THIS IS TO BE A | | | 4 STORY HOTEL. THIS PROJECT IS IDENTIFIED AS A | | | THRESHOLD BUILDING / FL S. S. 553.71(7) ?THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 1A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 1B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. | | | | | | FORMS E-MAILED TO: [email protected] THURS. | | | FEB. 09/2017 08:38 AM | | | | | | 1C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 1D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | 1E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 1F) FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, PLEASE | | | E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING ISSUED, | | | THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE APPROVED | | | AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, | | | TWO SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) | | | FOR THE THRESHOLD INSPECTOR, THE OTHER FOR THE MEP | | | INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE IN BLACK | | | & WHITE.. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING SPECIAL INSPECTORS. | | | | | | 1G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | | | | 1H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | 1I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | | WALLS AND CEILINGS. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2018-07-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-07-20 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-07-20 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2018-07-20 13:53:21 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.20.2018 | | | PERMIT NO.: 17010911 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THIS PERMIT REVIEW IS FOR THE HOTEL FOUNDATION ONLY! | | | | | | 2. THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT (CPD) SHALL BE SUBJECT TO ALL DEVELOPMENT | | | ORDER CONDITIONS AND DESIGN GUIDELINES OUTLINED IN | | | RESOLUTION NO. 307-17, APPROVED ON NOVEMBER 20, 2017, | | | AND AS MAY BE AMENDED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-03-23 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-03-23 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2018-03-23 16:15:43 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.23.2018 | | | PERMIT NO.: 17010911 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THIS PERMIT REVIEW IS FOR THE HOTEL FOUNDATION ONLY! | | | | | | 2. THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT (CPD) SHALL BE SUBJECT TO ALL DEVELOPMENT | | | ORDER CONDITIONS AND DESIGN GUIDELINES OUTLINED IN | | | RESOLUTION NO. 307-17, APPROVED ON NOVEMBER 20, 2017, | | | AND AS MAY BE AMENDED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-02-13 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-02-13 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2018-02-13 10:55:07 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.013.2018 | | | PERMIT NO.: 17010911 | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THIS PERMIT REVIEW IS FOR THE HOTEL FOUNDATION ONLY! | | | | | | 2. THE BANYAN CAY RESIDENTIAL/COMMERCIAL PLANNED | | | DEVELOPMENT (CPD) SHALL BE SUBJECT TO ALL DEVELOPMENT | | | ORDER CONDITIONS AND DESIGN GUIDELINES OUTLINED IN | | | RESOLUTION NO. 307-17, APPROVED ON NOVEMBER 20, 2017, | | | AND AS MAY BE AMENDED. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-07-20 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-07-20 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2017-07-20 15:05:04 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.20.2017 | | | PERMIT NO.: 17070911 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS THE SITE PLAN DOES NOT MATCH THAT WHICH WAS | | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT - | | | PLANNING DIVISION VIA MINOR AMENDMENT TO THE BANYAN CAY | | | PLANNED DEVELOPMENT ON MAY 13, 2016, AN AMENDMENT TO | | | THE PLANNED DEVELOPMENT WILL BE REQUIRED PRIOR TO | | | ISSUANCE OF THE PERMIT. SUCH AMENDMENT APPLICATION HAS | | | BEEN SUBMITTED BUT SHALL BE APPROVED PRIOR TO ISSUANCE | | | OF THE PERMIT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-04-14 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-04-14 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2017-04-14 15:10:08 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.27.2017 | | | PERMIT NO.: 17070911 | | | ADDRESS: 3200 N CONGRESS AVENUE | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: FOUNDATION/SLAB FOR NEW HOTEL | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. AS THE SITE PLAN DOES NOT MATCH THAT WHICH WAS | | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT - | | | PLANNING DIVISION VIA MINOR AMENDMENT TO THE BANYAN CAY | | | PLANNED DEVELOPMENT ON MAY 13, 2016, AN AMENDMENT TO | | | THE PLANNED DEVELOPMENT WILL BE REQUIRED PRIOR TO | | | ISSUANCE OF THE PERMIT. SUCH AMENDMENT APPLICATION HAS | | | BEEN SUBMITTED BUT SHALL BE APPROVED PRIOR TO ISSUANCE | | | OF THE PERMIT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-27 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-02-27 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-02-27 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2017-02-27 14:00:49 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.27.2017 | | | PERMIT NO.: 17070911 | | | ADDRESS: 3200 N CONGRESS AVENUE | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: FOUNDATION/SLAB FOR NEW HOTEL | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A SITE PLAN SHALL BE PROVIDED SHOWING THE PROPOSED | | | LOCATION OF THE FOUNDATION/SLAB. SITE PLAN SHALL MATCH | | | THAT WHICH WAS APPROVED BY THE DEVELOPMENT SERVICES | | | DEPARTMENT ? PLANNING DIVISION VIA MINOR AMENDMENT TO | | | THE BANYAN CAY PLANNED DEVELOPMENT ON MAY 13, 2016. IF | | | THE FOUNDATION/SLAB DIFFERS FROM THAT WHICH WAS | | | APPROVED, AN AMENDMENT TO THE PLANNED DEVELOPMENT WILL | | | BE REQUIRED PRIOR TO ISSUANCE OF THE PERMIT. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy