| Plan Review Stops For Permit 17010792 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-15 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-14 |
Time |
18:26 |
Sent To |
P |
|
| Notes |
| 2017-09-15 08:54:50 | BUILDING PROVISO | | | | | | 1) SUBMIT TWO (2) SETS OF PRODUCT APPROVALS FOR THE NEW | | | 4040 HORIZONTAL ROLLING EGRESS WINDOW IN THE EXISTING | | | BEDROOM. FBC107.3.4 | | | | | | BUILDING PROVISO | | | | | | 1) SUBMIT TWO (2) SETS OF PRODUCT APPROVALS FOR THE NEW | | | 4040 HORIZONTAL ROLLING EGRESS WINDOW IN THE EXISTING | | | BEDROOM. FBC107.3.4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-30 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-06-30 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2017-06-30 13:35:42 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE SURVEY THAT WAS SUBMITTED SHOWS THAT THE | | | EXISTING STRUCTURE IS 9.6 FEET FROM THE SIDE PROPERTY | | | LINES. THE PLANS SPECIFY A 5 FEET ADDITION TO THE WEST | | | SIDE OF THE EXISTING STRUCTURE. THIS WILL LEAVE A | | | DISTANCE OF 4.6 FEET TO THE PROPERTY LINE. THE SITE | | | PLAN ON SHEET A-1 SHOWS 5 FEET TO THE PROPERTY LINE. | | | PLEASE CORRECT. FBC 107.2.1 NOTE: THE ADDITIONAL BLOCK | | | WALL THAT IS SHOWN ON THE PLANS BESIDE THE EXISTING | | | EXTERIOR BLOCK WALL COULD BE ELIMINATED IN ORDER TO | | | PROVIDE AN ADDITIONAL 8" OF INTERIOR SPACE TO THE | | | PROPOSED ADDITION. | | | | | | 2) THE REVISED PLANS SPECIFY A 4040 HR EGRESS WINDOW IN | | | THE EXISTING BEDROOM. THE SOUTH ELEVATION ON SHEET A-2 | | | SHOWS A SINGLE HUNG WIND. PLEASE CLARIFY. IF THIS IS A | | | NEW WINDOW IN THE EXISTING OPENING SUBMIT 2 SETS OF | | | PRODUCT APPROVALS FOR THE HORIZONTAL SLIDING WINDOW. IF | | | IT IS EXISTING, SPECIFY AS SUCH ON THE PLANS. FBC | | | 107.2.1 | | | | | | 3) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE | | | FORMS AS REQUIRED. | | | | | | 4) PROVIDE THE FL# FOR THE JELD-WEN OPAQUE WOOD EDGE | | | STEEL EXTERIOR DOORS. THE DOCUMENTS THAT WERE SUBMITTED | | | DO NOT SPECIFY THE FL NUMBER. | | | | | | 5) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD, | | | CHARLES C. MITCHELL, P.E. FBC 107.3.4 | | | | | | 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-03-03 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-03-02 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2017-03-03 15:21:31 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. | | | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM | | | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND | | | RESCUE OPENING. VERIFY THAT THE ADDITION WILL NOT | | | INTERFERE WITH THE BEDROOM'S REQUIRED EMERGENCY EGRESS | | | OPENING. | | | | | | 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR THE ROOFING MATERIALS | | | AND THE EXTERIOR DOOR. | | | | | | 3) ON SHEET S-1 THE ROOF PLAN SHOWS A ONE FOOT OVERHANG | | | AND THE WALL SECTION HAS A TWO FOOT OVERHANG. PLEASE | | | COORDINATE THE PLANS WITH THE CORRECT DIMENSIONS FOR | | | THE OVERHANG. FBC 107.2.1 | | | | | | 4) THE SITE PLAN ON SHEET A-1 INDICATES THAT THE | | | EXTERIOR WALL OF THE NEW ADDITION IS 3.58' FROM THE | | | PROPERTY LINE. FBC-R302.1 REQUIRES THE UNDERSIDE OF THE | | | ONE FOOT ROOF OVERHANG AT THE GABLE END TO BE ONE HOUR | | | FIRE-RESISTANCE RATED IF IT IS LESS THAN THREE (3) FEET | | | OF THE PROPERTY LINE. PROJECTIONS THAT ARE LESS THAN | | | TWO (2) FEET OF THE PROPERTY LINE ARE NOT ALLOWED. | | | | | | 5) PROVIDE TWO SETS OF A DRAINAGE PLAN FOR THE ADDITION | | | THAT SHOWS COMPLIANCE WITH FBC- R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN | | | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE | | | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE | | | FIRST 10 FEET (3048 MM). EXCEPTION: WHERE LOT LINES, | | | WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6 | | | INCHES (152 MM) OF FALL WITHIN 10 FEET (3048 MM), | | | DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES | | | WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION | | | SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY FROM THE | | | BUILDING. | | | | | | 6) FBC ENERGY CONSERVATION SECTIONS R101.5.1.1.1 OR | | | R101.5.1.1.2. SUBMIT TWO SETS OF ENERGY COMPLIANCE | | | FORMS AS REQUIRED. | | | | | | 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-12 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-12 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-02-13 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-13 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-13 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2017-02-13 11:03:15 | PLEASE ADDRESS ZONING COMMENTS FOR AN ELECTRICAL | | | APPROVAL... | | | | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-22 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-24 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-30 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-30 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2017-06-28 15:52:43 | 6/28/17 REMOVED FROM BOARD, ROUTED TO RMCDOUGAL'S DESK. | | | LEM | | 2017-05-31 13:38:35 | R10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-03-03 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-01-23 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-12-04 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-12-04 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2017-12-04 11:53:50 | MU2017-31803, NO FEES WERE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-03-02 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-03-02 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2017-03-02 17:03:15 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-09-15 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-09-15 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-30 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-06-30 |
Time |
07:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-03-02 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-03-02 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2017-03-02 17:07:23 | THE BATH EXHAUST VENT IS THE ONLY MECHANICAL WORK SHOWN | | | ON THE PLANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-22 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-22 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-14 |
Time |
17:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-14 |
Time |
17:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-10 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-10 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2017-02-10 12:13:00 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE PLUMBING RISER DIAGRAM. PER WPB AMEND | | | TO FBC 107.3.5.3(11) | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-09-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-09-07 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-06-08 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2017-06-08 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-06-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-30 15:36:03 | ***************************ZONING REVIEW | | | FAILED******************************** | | | | | | ADDITION DOES NOT MEET THE MINIMUM 5 FOOT SIDE SETBACK | | | REQUIRED BY CODE. SITE PLAN, ALL PLANS AND SURVEY MUST | | | BE CONSISTENT. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-82-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2017-01-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-01-27 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2017-01-27 16:20:28 | ********ZONING REVIEW FAILED***************** | | | | | | IS THE FOOTPRINT OF THE BUILDING CHANGING? PLEASE DRAW | | | SETBACKS AND ADDITION INFORMATION ON SURVEY. | | | | | | ALANA WOOTEN | | | 561-822-1449 | | | [email protected] |
|
|