Plan Review Details - Permit 17010693
| Plan Review Stops For Permit 17010693 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-02-22 |
|
|
Cont ID |
|
| Sent By |
tmoore |
Date |
2017-02-22 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
tmoore |
Date |
2017-02-22 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2017-02-22 07:56:01 | OK TO ISSUE WITH REMAINING FEES PAID AND DEBRIS | | | DISPOSAL FORM COMPLETED AT PICK UP. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-21 |
|
|
Cont ID |
|
| Sent By |
tmoore |
Date |
2017-01-21 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
tmoore |
Date |
2017-01-21 |
Time |
09:45 |
Sent To |
ENG |
|
| Notes |
| 2017-01-21 10:10:37 | THESE ARE THE ITEMS THAT WILL NEED TO BE ADDRESSED | | | PRIOR TO ISSUANCE OF DEMO PERMIT. | | | | | | 1) A LICENSED PLUMBING CONTRACTOR WILL NEED TO PULL A | | | PERMIT TO CAP THE SEWER LATERAL, (THIS IS A | | | TURN-A-ROUND) PERMIT. WHEN THE CAP IS COMPLETED, THEY | | | WILL NEED TO REQUEST AND PASS A FINAL PLUMBING | | | INSPECTION A #703 ON THAT PERMIT #. ALSO, THE DEMO WILL | | | NEED TO BE KEPT WET. IF A BACKFLOW PREVENTER IS NEEDED, | | | NOW IS THE TIME TO INSTALL. | | | | | | 2) THE PROPERTY APPRAISER SITE, PAPA, NOTES THIS | | | PROPERTY AS 6 UNITS. ACCORDING TO NESHAP, OVER 4 UNITS | | | WILL REQUIRE AN ASBESTOS ABATEMENT SURVEY BE COMPLETED. | | | THE ARCHITECT ALSO NOTES ON HIS PLAN UNDER "ASBESTOS | | | WARNING NOTE" THE NEED FOR AN ASBESTOS SURVEY. | | | | | | 3) ENGINEERING AND HISTORIC'S PLAN REVIEW APPROVAL. THE | | | APPLICATION WILL BE ROUTED TO ENGINEERING NEXT. | | | | | | 4) A DEBRIS DISPOSAL FORM WILL NEED TO BE COMPLETED. | | | THIS CAN BE DONE AT PERMIT PICK UP. A SMALL FEE MAY | | | ACCOMPANY THIS FORM. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2017-02-20 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-02-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-02-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-02-20 14:08:00 | POLLUTION PREVENTION PLAN | | | PER MUNICODE 94-450 | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-02-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-02-14 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-02-14 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-02-22 |
|
|
Cont ID |
|
| Sent By |
tmoore |
Date |
2017-02-22 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
tmoore |
Date |
2017-02-22 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2017-01-20 14:23:30 | ROUTED TO TMOORE'S DESK |
|
|
|