Plan Review Details - Permit 17010610
Plan Review Stops For Permit 17010610
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-02-17 Cont ID  
Sent By jwitmer Date 2017-02-17 Time   Rev Time 0.00
Received By jwitmer Date 2017-02-17 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-01-23 Cont ID  
Sent By jwitmer Date 2017-01-23 Time 14:57 Rev Time 0.00
Received By jwitmer Date 2017-01-23 Time 14:57 Sent To  
Notes
2017-01-23 15:08:34 
 BUILDING PLAN REVIEW
 REVISION: 17010610
 PERMIT: 14060196
 ADD:777 S FLAGLER 12TH FLOOR
 CONT: WOOLEMS / AMADOU DIAL
 TEL: (561) 891-1116
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 23/2017
 ACTION: DENIED
  
 1) SHEET REV-1A THE LOWER LEFT HAND CORNER OF THE SHEET
 SHOWS CARPET BEING ADDED TO THE MONUMENTAL STAIRS.
 PLEASE SHOW COMPLIANCE WITH THE 2010 FBC-B SECTIONS:
 804.4INTERIOR FLOOR FINISH REQUIREMENTS. IN ALL
 OCCUPANCIES INTERIOR FLOOR FINISHES AND FLOOR COVERING
 MATERIALS IN EXIT ENCLOSURES, EXIT PASSAGEWAYS,
 CORRIDORS AND ROOMS OR SPACES NOT SEPARATED FROM
 CORRIDORS BY FULL HEIGHT PARTITIONS EXTENDING FROM THE
 FLOOR TO THE UNDERSIDE OF THE CEILING SHALL WITHSTAND A
 MINIMUM CRITICAL REDIANT FLUX AS SPECIFIED IN SECTION
 804.4.1.
 804.4.1 MINIMUM CRITICAL REDIANT FLUX. INTERIOR FINISH
 FLOORSAND FLOOR COVERING MATERIALS IN EXIT ENCLOSURES,
 EXIT PASSAGEWAYS AND CORRIDORS SHALL NOT BE LESS THAN
 CLASS II IN A,B AND S. IN ALL AREAS, FLOOR COVERING
 MATERIALS SHALL COMPLY WITH THE DOCFF-! PILL TEST (CPCS
 16 CFR, PART 1630.
 EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH
 AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 903.3.1.1 CLASS II MATERIALS ARE REQUIRED AND MATERIALS
 COMPLYING WITH THE DOCFF-I PILL TEST (CPCS 16 CFR, PART
 1630) ARE PERMITTED IN ANY AREA WHERE CLASS II
 MATERIALS ARE REQUIRED,
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-17 Cont ID  
Sent By   Date 2017-02-17 Time   Rev Time 0.00
Received By lmarchan Date 2017-02-13 Time 12:45 Sent To  
Notes
2017-02-14 12:45:27RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-23 Cont ID  
Sent By jwitmer Date 2017-01-23 Time 15:08 Rev Time 0.00
Received By jwitmer Date 2017-01-18 Time 13:56 Sent To  
Notes
2017-01-19 13:56:21REVISION ROUTED TO JWITMER


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved