| 2017-01-23 11:31:31 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17010476 FENCE/ ALUMINUM RAILING |
| | PERMIT |
| | W. P. B. PERMIT: 16110448 POOL |
| | ADD: 7130 OKEECHOBEE BLVD. |
| | CONT: CLIMATROL QUALITY ALUM PRODUCTS |
| | TEL: 1-800-273-7857 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 1ST REVIEW |
| | DATE: MON. JAN. 23/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) THE SITE PLAN SHEET 1OF 1 BY J. MORTON LANDSCAPE |
| | ARCHITECT IS NOT SIGNED NOR SEALED. PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY |
| | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN |
| | PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | |
| | 2) THE SITE PLAN SHEET 1OF 1 BY J. MORTON LANDSCAPE |
| | ARCHITECT SEEMS TO BE SHRUNK IN SCALE. NEITHER THE |
| | PERMIT APPLICATION NOR THE SITE PLANS HIGHLIGHT WHICH |
| | AREAS ARE TO BE FENCED IN. PLANS ARE TOO SMALL TO READ. |
| | PLANS INDICATE THE PLANS ARE DRAWN TO 1INCH=50 FEET. IN |
| | SCALING THE DRAWINGS THE PLANS ARE SHRUNK OVER 50 %. |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.2.1.4 QUALITY OF BUILDING PLANS. |
| | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH |
| | SCALE UPON SUBSTANTIAL PAPER. THE BUILDING OFFICIAL MAY |
| | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS |
| | FOR PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE |
| | CONFORMITY TO ITS RECORD RETENTION PROGRAM. |
| | |
| | 3) PLEASE SEE COMMENT FROM THE POOL PERMIT AND HOW WILL |
| | COMPLIANCE BE ACCOMPLISHED. SHEET 1 OF 7 SHOW SECTIONS |
| | OF FENCING BY OTHERS BETWEEN BUILDINGS. THIS PLAN |
| | DEPICTS THE OUTLINE OF THE APARTMENT BUILDINGS AND |
| | RECREATION/ LEASING CENTER WHICH SURROUND THE POOL AND |
| | POOL DECK. THE BUILDING ELEVATION PLANS OF THESE |
| | BUILDINGS DOES NOT INDICATE HOW SEPARATION FROM THE |
| | APARTMENT PATIO DECKS (FIRST FLOOR) AND THE POOL AND |
| | POOL DECK AREAS AND COMPLIANCE WITH 2014 FBC-B |
| | 454.1.3.1.9. ACCESS THROUGH THE BARRIER OR FENCE FROM |
| | DWELLING UNITS, SUCH AS HOMES, APARTMENTS, MOTEL ROOMS |
| | AND HOTEL ROOMS, SHALL BE THROUGH SELF-CLOSING, |
| | SELF-LATCHING LOCKABLE GATES OF 48 INCH (1219 MM) |
| | MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH THE LATCH |
| | LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM THE |
| | BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) BELOW |
| | THE TOP OF THE GATE ON THE POOL SIDE. |
| | |
| | 3) COMMENTS FROM THE POOL PERMIT: SHEET 1 OF 7 THE SAME |
| | POOL SEPARATION ISSUE OCCURS WITHIN THE RECREATION/ |
| | LEASING BUILDING AND POOL/ POOL DECK AREA PLEASE SHOW |
| | COMPLIANCE WITH: |
| | 2014 FBC-B 454.1.3.1.9. ACCESS THROUGH THE BARRIER OR |
| | FENCE FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, |
| | MOTEL ROOMS AND HOTEL ROOMS, SHALL BE THROUGH |
| | SELF-CLOSING, SELF-LATCHING LOCKABLE GATES OF 48 INCH |
| | (1219 MM) MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH |
| | THE LATCH LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM |
| | THE BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) |
| | BELOW THE TOP OF THE GATE ON THE POOL SIDE. IF THE |
| | SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING |
| | AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR |
| | INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF |
| | SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 |
| | MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED |
| | FLOOR OR GROUND. |
| | DOORED ACCESS POINTS FROM PUBLIC ROOMS SUCH AS LOBBIES |
| | OR CLUB HOUSES NEED NOT BE THROUGH GATES IF THE DOOR(S) |
| | MEET THE SAME SELF-CLOSING, SELF-LATCHING REQUIREMENTS |
| | AS A GATE. GATES SHALL OPEN OUTWARD AWAY FROM THE POOL |
| | AREA. |
| | |
| | THIS FENCE PERMIT A PAGE FROM THE 2014 FBC-B HAS |
| | SECTION 454.1.3.1.9 HIGHLIGHTED. PLEASE REVIEW 2014 |
| | FLORIDA BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS |
| | TO THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION |
| | SECTION 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | SUCH INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL |
| | CODES SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR |
| | SHALL THE TERM "LEGAL" OR |
| | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. SHOW COMPLIANCE ON THE PLANS!!!! |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |