| 2017-02-13 14:41:53 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD. |
| | |
| | 2) SPECIFY THE APPLICABLE CATEGORY OF THE SUNROOM ON |
| | THE PLANS. FBC-R301.2.1.1.2.2 - FOR THE PURPOSE OF |
| | APPLYING THE CRITERIA OF THE AAMA/NPEA/NSA 2100, |
| | SUNROOMS SHALL BE CATEGORIZED IN ONE OF THE FOLLOWING |
| | CATEGORIES BY THE PERMIT APPLICANT, DESIGN PROFESSIONAL |
| | OR THE PROPERTY OWNER WHERE THE SUNROOM IS BEING |
| | CONSTRUCTED. |
| | |
| | CATEGORY I: A THERMALLY ISOLATED SUNROOM WITH WALLS |
| | THAT ARE EITHER OPEN OR ENCLOSED WITH INSECT SCREENING |
| | OR 0.5 MM (20 MIL) MAXIMUM THICKNESS PLASTIC FILM. THE |
| | SPACE IS DEFINED AS A NONHABITABLE, NONCONDITIONED |
| | SUNROOM. |
| | |
| | CATEGORY II: A THERMALLY ISOLATED SUNROOM WITH ENCLOSED |
| | WALLS. THE OPENINGS ARE PERMITTED TO BE ENCLOSED WITH |
| | TRANSLUCENT OR TRANSPARENT PLASTIC OR GLASS. THE SPACE |
| | IS DEFINED AS A NONHABITABLE, NONCONDITIONED SUNROOM. |
| | |
| | CATEGORY III: A THERMALLY ISOLATED SUNROOM WITH |
| | ENCLOSED WALLS. THE OPENINGS ARE PERMITTED TO BE |
| | ENCLOSED WITH TRANSLUCENT OR TRANSPARENT PLASTIC OR |
| | GLASS. THE SUNROOM FENESTRATION COMPLIES WITH |
| | ADDITIONAL REQUIREMENTS FOR AIR INFILTRATION RESISTANCE |
| | AND WATER PENETRATION RESISTANCE. THE SPACE IS DEFINED |
| | AS A NONHABITABLE, NONCONDITIONED SUNROOM. |
| | |
| | CATEGORY IV: A THERMALLY ISOLATED SUNROOM WITH ENCLOSED |
| | WALLS. THE SUNROOM IS DESIGNED TO BE HEATED AND/OR |
| | COOLED BY A SEPARATE TEMPERATURE CONTROL OR SYSTEM AND |
| | IS THERMALLY ISOLATED FROM THE PRIMARY STRUCTURE. THE |
| | SUNROOM FENESTRATION COMPLIES WITH ADDITIONAL |
| | REQUIREMENTS FOR AIR INFILTRATION RESISTANCE, WATER |
| | PENETRATION RESISTANCE, AND THERMAL PERFORMANCE. THE |
| | SPACE IS DEFINED AS A NONHABITABLE AND CONDITIONED |
| | SUNROOM. |
| | |
| | CATEGORY V: A SUNROOM WITH ENCLOSED WALLS. THE SUNROOM |
| | IS DESIGNED TO BE HEATED AND/OR COOLED AND IS OPEN TO |
| | THE MAIN STRUCTURE. THE SUNROOM FENESTRATION COMPLIES |
| | WITH ADDITIONAL REQUIREMENTS FOR AIR INFILTRATION |
| | RESISTANCE, WATER PENETRATION RESISTANCE, AND THERMAL |
| | PERFORMANCE. THE SPACE IS DEFINED AS A HABITABLE AND |
| | CONDITIONED SUNROOM. |
| | |
| | |