Plan Review Details - Permit 17010403
Plan Review Stops For Permit 17010403
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-03-06 Cont ID  
Sent By cthroop Date 2017-03-06 Time 08:14 Rev Time 0.00
Received By cthroop Date 2017-03-06 Time 08:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-02-06 Cont ID  
Sent By cthroop Date 2017-02-06 Time 10:25 Rev Time 0.00
Received By cthroop Date 2017-02-06 Time 10:25 Sent To P
Notes
2017-02-06 10:26:31BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. MECH., ELECTRICAL & PLUMBING PERMITS REQUIRED.
 2. PROVIDE ASTM'S E-90 & E-492 FOR FLOOR TILE.
 3. IDENTIFY COMMOM/RATED WALLS ON PLANS.
 4. PROVIDE DETAILS FOR RATED WALL CONSTRUCTION.
 5. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE SUBMITTED PLANS
 AND SUPPORTING DOCUMENTS PER FBC 107.
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E - 90-02
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-04
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-02-27 Cont ID  
Sent By vperez Date 2017-02-27 Time 13:12 Rev Time 0.00
Received By vperez Date 2017-02-27 Time 13:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-02-14 Cont ID  
Sent By vperez Date 2017-02-14 Time 12:24 Rev Time 0.00
Received By vperez Date 2017-02-14 Time 12:24 Sent To M
Notes
2017-02-14 12:27:12INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1- PLEASE NOTE ON PLANS IF ELECTRICAL DEVICES ARE BEING
 REPLACED IN THE KITCHEN AREA, PERMIT REQUIRED.
 2- PER FBC RES 3143.1 WHEN AN ALTERATION OCCURS ON
 PROPERTY, SMOKE DETCTORS ARE TO BE INSTALLED PER CODE
 SECTION. CLARIFY IF THERE ARE EXISTING SMOKE DETECTORS
 INSTALLED.
  
 VAL PEREZ
 *6717

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-23 Cont ID  
Sent By hmoser Date 2017-03-23 Time 13:05 Rev Time 0.00
Received By hmoser Date 2017-02-23 Time 11:46 Sent To  
Notes
2017-02-24 11:48:20B12

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-02-15 Cont ID  
Sent By cthroop Date 2017-02-15 Time 07:45 Rev Time 0.00
Received By lmarchan Date 2017-01-12 Time 13:25 Sent To  
Notes
2017-01-13 13:25:31BLDG MISC 1

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2017-03-23 Cont ID  
Sent By hmoser Date 2017-03-23 Time 13:03 Rev Time 0.00
Received By hmoser Date 2017-03-23 Time 12:07 Sent To  
Notes
2017-03-23 13:05:36THERE IS NO MECHANICAL WORK AT THIS TIME HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-02-14 Cont ID  
Sent By jvalido Date 2017-02-14 Time 18:19 Rev Time 0.00
Received By jvalido Date 2017-02-14 Time 18:13 Sent To  
Notes
2017-02-14 18:17:47CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE COMPLETE SCOPE OF WORK FOR MECHANICAL. IF
 NO HVAC WORK IS BEING DONE STATE SO ON PLANS.
  
 FLORIDA ENERGY CODE FBC 2014
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-03-07 Cont ID  
Sent By gjohnson Date 2017-03-07 Time 14:52 Rev Time 0.00
Received By gjohnson Date 2017-03-07 Time 14:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-02-10 Cont ID  
Sent By gjohnson Date 2017-02-10 Time 11:56 Rev Time 0.00
Received By gjohnson Date 2017-02-10 Time 11:56 Sent To  
Notes
2017-02-10 11:56:231ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE A DETAILED SCOPE OF WORK FOR PLUMBING
 TO TO DONE UNDER THIS PERMIT. PER WPB AMED TO FBC
 107.2.1
  
 2. THE WATER RESISTANT WALL BOARD AROUND THE TUB SHALL
 COMPLY WITH FBC 2509.2 BASE FOR TILE.
 GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS,
 DISCRETE NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE
 SHEETS OR NONASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS
 BACKER UNITS IN COMPLIANCE WITH ASTM C 1178, C 1288 OR
 C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER
 RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE
 IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN
 SHOWER AREAS.
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  