|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17010366
| Plan Review Stops For Permit 17010366 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-02 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-01-31 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-02-07 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-02-07 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-02-06 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2017-02-16 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-02-16 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-02-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-02-03 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-02-03 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-02-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-02-16 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-01-25 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-01 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-02-01 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-02-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-17 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-17 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2017-02-17 15:15:10 | FUEL GAS PAGES REMOVED FROM THIS REVISION SUBMITTAL | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-02-11 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-02-11 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-02-04 |
Time |
2:30 |
Sent To |
|
|
| Notes |
| 2017-02-11 07:50:00 | 1) SHT. P-4.05 - THE INFORMATION BOXES FOR THE MEDIUM | | | PRESSURE GAS SYSTEM SHOW TWO DIFFERENT TOTAL BTU LOAD | | | VALUES FOR THE MEDIUM PRESSURE GAS SYSTEMS. TTHE BTU | | | LOADS SHOULD BE THE SAME. CLARIFY.2010 FBC-FUEL GAS | | | SEC. 402.2. | | | 2) SHT.P-4.05 - THE INFORMATION BOXES FOR THE MEDIUM | | | PRESSURE GAS SYSTEMS SHOW DIFFERENT PIPE DEVELOPED | | | LENGTH MEASUREMENTS. THESE MEASUREMENTS SHOULD BE THE | | | SAME. CLARIFY. 2010 FBC- FUEL GAS SEC.402.4.1. | | | 3) SHT. P-4.05 - THE INFORMATION BOX FOR THE GAS SYSTEM | | | SHOWING 4,650,000 BTU'S REFERS TO A 2 PSI SYSTEM BUT | | | THE NOTE UNDER THIS SAME BOX REFERS TO TABLE 402.4 (2) | | | WHICH IS FOR A LESS THAN 2 PSI SYSTEM. CLARIFY. | | | 4) SHT. P-4.06 - THE GAS ISOMETRIC SHOWS A 5 INCH | | | SUPPLY LINE ON THE DISCHARGE SIDE OF THE METER AND THE | | | LINE IS ALSO SHOWN AS 2 INCHES IN DIAMETER. CLARIFY. | | | 5) SHT. P- 4.07 - SIZE THE WATER SUPPLY LINE TO THE | | | HOSE BIBBS IN THE CORRIDOR SHOWN IN THE CLOUDED RISER. | | | PLEASE SUPPLY THE RISER WITH A TAG NUMBER FOR | | | IDENTIFICATION. THE SAME APPLIES TO SHT. P-4.11. | | | 6) SHT.P-4.10 - THE INFORMATION BOXES FOR THE MEDIUM | | | PRESSURE GAS SYSTEMS SHOW DIFFERENT PIPE DEVELOPED | | | LENGTH MEASUREMENTS.THESE MEASUREMENTS SHOULD BE THE | | | SAME. CLARIFY. 2010 FBC-FUEL GAS SEC.402.4.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-02-10 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-02-02 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2017-02-10 08:19:42 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.10.2017 | | | PERMIT NO.: 15050262 | | | ADDRESS: 1851 DIVISION AVENUE | | | CONTRACTOR/CONTACT: | | | TELEPHONE NO.: | | | SCOPE OF REVIEW: NEW MULTIFAMILY DEVELOPMENT. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. A MINOR AMENDMENT WILL NEED TO BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION TO | | | REFLECT ALL OF THE REVISIONS THAT HAVE OCCURRED SINCE | | | THE APPROVAL OF RESOLUTION NO. 72-15. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |