| 2017-01-23 09:33:02 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17010126 |
| | ADD: 3199 CUMBERLAND DRIVE |
| | CONT: J. COMPTON ELECTRIC, INC. |
| | TEL: 561-588-6559 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. JAN. 23/2017 |
| | ACTION: DENIED |
| | |
| | 1) COMPLIED. CONCRETE PAD AND TELELECTRONIC EQUIPMENT |
| | RACKS. |
| | |
| | 2) THE WIND DESIGN CRITERIA SHOWS THIS BUILDING IS 160 |
| | MPH. PLEASE REFER TO TABLE 1604.5 RISK CATEGORY OF |
| | BUILDINGS AND OTHER STRUCTURES. THE BUILDING RISK |
| | CATEGORY INDICATED ON THE PLANS IS RISK CATEGORY II |
| | WITH A 170 VULT WIND DESIGN, THIS STRUCTURE IS NOT |
| | AGRICULTURAL OUT BUILDING NOT A TEMPORARY FACILITY, |
| | MINOR STORAGE FACILITY NOR SCREEN ENCLOSURE. AFTER THE |
| | 2004 & 2005 HURRICANES WE WERE REQUIRING THE CELL |
| | TOWERS TO BE CLASSIFIED AS A RISK CATEGORY III. THROUGH |
| | THE APPLICANT A LETTER CAME BACK FROM THE STATE THAT |
| | THE CELL TOWERS AND ASSOCIATED EQUIPMENT WAS TO BE |
| | INTERPRETED AS A RISK CATEGORY II NOT AN III. PLEASE |
| | CORRECT THE WIND SPEED. |
| | |
| | 3) SHEET C-6 SHOWS AN ANCHORING DETAIL. THIS DETAIL |
| | WILL NEED TO BE RE-EVALUATED FOR A 170 VULT MPH WIND |
| | SPEED. TABLE 1604.5 AND FIGURE 1609 A RISK CATEGORY II |
| | BUILDINGS. |
| | |
| | 4) SHEET C-5 THE ATTENDANT UTILITIES PROPANE GAS TANK |
| | AND METAL GENERATOR ENCLOSURE SHOW ANCHORING DETAILS |
| | BUT THERE IS NO WIND DESIGN AS TO WHAT WIND SPEED. 2014 |
| | FBC-B 1603.1.4 WIND DESIGN DATA. |
| | |
| | 5) SHEET C-2 AND OTHER SHEETS SHOWING AN ELEVATION. |
| | THROUGHOUT THE SET OF PLANS ELEVATION IS GIVEN IN THE |
| | TERMS NAVD 88. THE CITY AND ALL FLOOD MAPS ADOPTED ARE |
| | STILL USING NGVD 29 PLEASE CORRECT ELEVATIONS, OR SHOW |
| | THE EQUIVALENCY IN NGVD. 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 6) REPORT TRANSMISSION LINE PROJECT T00000016270 BY |
| | JASON TRUCKENBROD, P. E. IS A COPY OF SIGNATURE AND |
| | SEAL. |
| | 61G15-23.001 ENGINEERS SEALS ACCEPTABLE TO THE BOARD. |
| | SAID SEAL SHALL BE A MINIMUM OF 1 7/8 INCHES IN |
| | DIAMETER, TO SAY LICENSE NOT CERTIFICATE. ALL ENGINEERS |
| | MUST BE UTILIZING SAID SEAL NO LATER THAN JANUARY 1, |
| | 2006. |
| | |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | |
| | FL ADMIN CODE 61G15-23.002 ENGINEERS |
| | EFFECTIVE DATE 05/06/2009. (2)(A) EVERY SHEET OF PLANS |
| | AND PRINTS WHICH MUST BE SEALED UNDER THE PROVISIONS OF |
| | CHAPTER 471, F.S., SHALL BE SEALED, SIGNED AND DATED BY |
| | THE PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. |
| | |
| | 7) REPORT TRANSMISSION LINE PROJECT T00000016270 |
| | INDICATES ATTACHED FOUNDATION REPORT FOR CALCULATIONS |
| | OF THE REQUIRED SET DEPTH AND BACKFILL. NO SUCH |
| | CALCULATIONS ARE FOUND IN REPORT, NOTE TO BE SIGNED AND |
| | SEALED BY THE ENGINEER OF CALCULATIONS. 61G15-23.002(2) |
| | FL. ADMIN. CODE. A COVER SHEET OR INDEX SHEET FOR |
| | ENGINEERING SPECIFICATIONS MAY BE USED AND THAT SHEET |
| | MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION |
| | & PREPARATION OF EACH SECTION OF THE ENGINEERING |
| | SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER |
| | SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER |
| | THE COVER SHEET OR INDEX SHEET. . |
| | 8) PLEASE INDICATE HOW THE FOUNDATION DESIGN WAS |
| | DERIVED WITHOUT A SOILS REPORT? 1803.5.2 QUESTIONABLE |
| | SOIL. |
| | |
| | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |