Plan Review Details - Permit 17010057
| Plan Review Stops For Permit 17010057 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-12 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-12 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2017-01-12 14:12:26 | PROVISO 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] SEPERATE STRUCTURE SHALL HAVE A SINGLE BRANCH | | | CIRCUIT THEREFORE MEETING THE EXCEPTION REQUIREMENTS | | | NEC 250.32 (GROUNDING SEPERATE STRUCTURE). AN EGC WILL | | | BE ROUTED ALONG THE CIRCUIT CONDUCTORS FOR FAULT | | | PROTECTION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-05 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-05 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2017-01-05 18:05:52 | 1ST REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1] CLARIFY SCOPE OF WORK, THE APPLICATION CALLS OUT FOR | | | INTERIOR WIRING? THIS REQUIRES AN ELECTRICAL FLOOR PLAN | | | MEETING MINIMUM PROVISIONS SUCH AS RECEPTACLE OUTLET | | | SPACING, LIGHTING OUTLET IN HABITABLE ROOMS, SMOKE | | | ALARMS, TAMPER-RESISTANT RECEPTACLES, & AFCI, GFCI | | | PROTECTION. FBC 107 (SHOW COMPLIANCE). | | | | | | 2] ADD AN INTERSYSTEM BONDING TERMINAL TO THE GROUNDING | | | DETAIL ON RISER DIAGRAM. NEC 250.94 | | | | | | 3] THE LOAD CALCULATION ARE INADEQUATE, PLEASE REFRENCE | | | NEC 220.82 (OPTIONAL) AND PROVIDE THE MINIMUM 3VA FOR | | | GENERAL LIGHTING PLUS THE 2 SMALL APPLIANCE CIRCUITS | | | 1500VA EACH. IN ADDITION THE DEMAND PERCENTAGE IS 40% | | | NOT 45% PLEASE CORRECT ACCORDINGLY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-12 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-10 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2017-01-11 13:52:06 | RESUB ROUTED TO MVALDES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2017-01-05 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2017-01-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2017-01-04 14:43:15 | ROUTED TO ELECTRICAL INBOX |
|
|
|