| Plan Review Stops For Permit 16120948 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-21 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-21 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2017-07-21 13:42:14 | ROOFING SUBMITTAL TO BE SUBMITTED AT TIME OF ROOF | | | PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-20 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-20 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2017-07-20 10:29:36 | | | | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | 2. PROVIDE PRODUCT APPROVALS FOR NEW ROOF SYSTEM. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-04-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-04-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-04-24 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2017-04-24 10:44:30 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT MAY BE REQUIRED. STATE PERCENTAGE OF | | | EXISTING ROOF OR SQUARE FOOTAGE OF EXISTING ROOF | | | REPAIRS. | | | 2. SEE PLAN PAGE A-4, CHANGE CODE REFERENCE FROM FBC | | | 2010 TO FBC 2014 5TH ED. | | | 3. PROVIDE WINDOW SCHEDULE. | | | 4. PROVIDE WINDOW AND DOOR PRODUCT APPROVALS. | | | 4A. IF NON-IMPACT DOORS OR WINDOWS ARE INSTALLED, | | | PROVIDE SHUTTER SCHEDULE AND PRODUCT APPROVALS. | | | 5. SEE PLAN PAGE A-1, EXISTING BLDG. LEVEL III | | | ALTERATION SECTION 401.4 DOES NOT EXIST. CHANGE CODE | | | REFERENCE TO FBC2014 5TH ED. EXISTING BUILDING | | | ALTERATION LEVEL III SECTION 505.1. | | | 6. PROVIDE DETAIL OF EXTERIOR WALL ASSEMBLY. SHOW | | | TYPICAL FRAMING AT DOOR AND WINDOW OPENINGS, DRAINAGE | | | PLANE AND FASTENER SCHEDULE FOR EXTERIOR SIDING. | | | 7. PROVIDE REPAIR DETAIL FOR ANY STRUCTURAL CONCRETE | | | REPAIRS. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-01-13 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-01-13 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2017-01-13 11:19:18 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1, CANNOT IDENTIFY WHICH PERMIT APPLICATION APPLIES TO | | | WHICH STRUCTURE. | | | 2. PROVIDE SITE PLAN WITH PROPERTY LINE SETBACKS AND | | | DEMENSIONS BETWEEN STRUCTURES. INDICATE ADDRESS AND | | | UNIT NUMBER ON EACH STRUCTURE. | | | 3. NO REVIEW PERFORMED AT THIS TIME. | | | | | | COMPLY WITH COMMENTS AND RE-SUBMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-04-17 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-17 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-17 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-01-25 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-25 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-25 |
Time |
11:55 |
Sent To |
Z |
|
| Notes |
| 2017-01-25 11:55:34 | 2ND REVIEW- | | | | | | ORIGINAL COMMENTS 4 AND 5 ADDRESSED | | | | | | PENDING 1,2, 3,6,7 AND 8 PLEASE ADDRESS | | | ZONING HAS DISSAPROVED MULTIPLE UNITS, PLEASE CLARIFY | | | BEFORE RESUBMITTING | | | | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-21 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-07 |
Time |
14:10 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-04 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-29 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-01-27 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-01-27 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-12-29 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2016-12-30 11:40:30 | B28 | | | **TRAVELLING WITH 16080345** |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-21 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-12 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-04 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-04 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2017-05-04 16:57:19 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16120948 | | | 5/4/17 | | | | | | 1) THE ENERGYGAUGE FORM R405-2014 IS INDICATING A NEW | | | 17.5 SEER AC SYSTEM, HOWEVER IT IS LISTED AS 16 SEER ON | | | THE PLAN- PLEASE CORRECT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-01-05 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-01-05 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2017-01-05 07:54:25 | 1ST REVIEW FBC-2014 RESIDIENTIAL MECHANICAL | | | PERMIT #16120948 | | | 1/5/17 | | | | | | 1) PROVIDE AC EQUIPMENT SCHEDULES ON THE PLANS | | | INDICATING MAKES, MODELS, COOLING AND HEATING | | | CAPACITIES, AND EFFICIENCY RATINGS. THE SUBMIITTED AC | | | AND ENERGY CALCULATIONS CANNOT BE REVIEWED IN ENTIRETY | | | WITHOUT SYSTEMS' INFORMATION. PLEASE NOTE THAT THE | | | SYSTEM IS LISTED AS "GENERIC" UNDER THE EQUIPMENT | | | SUMMARY ON THE AC CALCULATIONS. | | | | | | 2) THE COOLING AND HEATING SYSTEM COMPLIANCE DATA ON | | | THE SUBMITTED ENERGYGAUGE FORM R405-2014 DOES NOT MATCH | | | THE PLANS: A) THE THROUGH THE WALL SYSTEMS SHOWN ON THE | | | PLAN ARE LISTED AS ONE "CENTRAL UNIT" ON THE FORM. B) | | | THE REVERSE CYCLE HEATING SYSTEMS SHOWN ON THE PLAN ARE | | | LISTED AS HEAT STRIPS ON THE FORM. | | | | | | 3) THE ENERGYGAUGE FORM MUST BE SIGNED AND DATED BY THE | | | OWNER/AGENT. | | | | | | 4) THE PLANS MUST BE REVISED TO SHOW THE INSULATION | | | R-VALUES IN THE WALLS AND CEILING IN ORDER TO VERIFY | | | THE VALUES LISTED ON THE ENERGY FORM R405-2014 ARE | | | ACCURATE. | | | | | | 5) THE ENERGY FORM R405 IS LISTING EITHER NEW OR | | | EXISTING DOUBLE-PANED WINDOWS AT 0.29 U-FACTOR/0.23 | | | SHGC. PLEASE PROVIDE A WINDOW SCHEDULE ON THE PLAN AND | | | SUBMIT MANUFACTURER'S DATA SHEET FOR REVIEW. | | | | | | 6) PROVIDE A DRYER VENTING PLAN. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-21 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-21 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-04-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-20 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-20 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2017-04-20 10:04:30 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A-4 THE WATER HEATER SHOWN IN AC CLOSET IS NOT | | | SHOWN ON EXISTING PLAN IT IS SHOWN ON PREVIOUS PLAN ON | | | THE EXTERIOR NEXT TO KITCHEN. PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. SHT. A-4 THE WASHING MACHINE IS NOT SHOWN ON | | | EXISTING PLAN OR ON ANY PREVIOUS PLANS IS THIS A NEW | | | INSTALLATION. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. PLEASE PROVIDE PLUMBING RISER DIAGRAM FOR ANY NEW | | | PIPING. PER WPB AMEND TO FBC 107.3.5.3(11) | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-01-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-23 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-01-23 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-20 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-20 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2017-07-20 10:31:12 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ROOFING PERMIT ON HOLD. PROVIDE PRODUCT APPROVALS AT | | | TIME OF ROOFING PERMIT. | | | | | | 1. FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-04-18 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-04-18 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-04-18 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-01-27 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-01-27 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-01-25 |
Time |
15:12 |
Sent To |
I |
|
| Notes |
|
|