Plan Review Details - Permit 16120833
| Plan Review Stops For Permit 16120833 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-01-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-01-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-01-20 |
Time |
13:09 |
Sent To |
M |
|
| Notes |
| 2017-01-20 13:23:22 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: PARENTHESIS | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) A "NO PRESSURE TEST" NOTE IS INDICATED ON THE | | | SUBMITTAL. | | | | | | PER NFPA 13, A "NO PRESSURE TEST" IS NOT INDICATED IN | | | ANY CODE REFERENCE. | | | | | | PER NFPA 13, WHERE A SYSTEM CAN NOT BE ISOLATED A | | | "SYSTEM WORKING PRESSURE TEST" SHALL BE DONE. | | | | | | | | | SPRINKLER TESTING | | | 24.2 ACCEPTANCE REQUIREMENTS. | | | 24.2.1* HYDROSTATIC TESTS. | | | 24.2.1.1 UNLESS PERMITTED BY 24.2.1.2 THROUGH 24.2.1.8, | | | ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO | | | SYSTEM WORKING PRESSURE SHALL BE HYDROSTATICALLY TESTED | | | AT 200 PSI (13.8 BAR) AND SHALL MAINTAIN THAT PRESSURE | | | WITHOUT LOSS FOR 2 HOURS. | | | | | | 24.2.1.6 MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS | | | RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF | | | SYSTEM WORKING PRESSURE. | | | | | | 24.2.1.7 LOSS SHALL BE DETERMINED BY A DROP IN GAUGE | | | PRESSURE OR VISUAL LEAKAGE. | | | | | | | | | PLEASE ENSURE A PRESSURE GAUGE IS PROVIDED AND THE | | | SYSTEM WORKING PRESSURE IS IDENTIFIED. A TEST WILL | | | CONDUCTED FOR 2 HOURS DOCUMENTING ANY PRESSURE LOSS OR | | | VISUAL LEAKAGE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-12-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-12-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-12-28 |
Time |
16:12 |
Sent To |
M |
|
| Notes |
| 2016-12-28 16:45:37 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) THERE IS A CALL-OUT NOTE - 01 - INDICATING | | | PRELIMIARY FIRE PROTECTION PLAN AND IN PARENTHESES "FOR | | | REFERENCE ONLY - COMPLETE ENGINEERED FIRE PROTECTION | | | SHOP DRAWING PLANS TO BE PROVIDED FOR REVIEW AND | | | APPROVAL" | | | | | | PLEASE CORRECT OR CLARIFY. | | | | | | | | | | | | 2) PLEASE PROVIDE MANUFACTURES SPEC SHEETS FOR ALL | | | INSTALLED EQUIPMENT FOR FEILD VERIFICATION PURPOSES. | | | | | | | | | | | | 3) PER NFPA 13 THERE ARE MORE THAN 20 HEADS AND THE | | | MODIFICATIONS SUCH AS RELOCATED DROPS THAT CAN NOT BE | | | ISOLATED SHALL NOT REQUIRE TESTING IN EXCESS OF WORKING | | | PRESSURE. | | | | | | AN ISOLATION VALVE CAN NOT BE INSTALLED ON AN ARM OVER, | | | BUT IT CAN BE INSTALLED FOR THE ENTIRE SYSTEM IF | | | POSSIBLE AND APPLICABLE. | | | | | | THE INSTALLTION IS LIMITED TO AN OCCUPANCY THAT MAY | | | HAVE AN ISOLATION VALVE OR ONE THAT CAN BE INSTALLED | | | FOR TESTING OF 200PSI FOR 2 HOURS. | | | | | | PLEASE REVIEW THIS INSTALLATION AND PROVIDE AN | | | ISOLATION VALVE IF POSSIBLE AND APPLICABLE. | | | | | | PROVIDE A NOTE INDICATING IF ONE WILL BE INSTALLED OR | | | WHY IT CAN NOT BE INSTALLED. | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-01-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-01-27 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-01-18 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2017-01-19 09:20:02 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-01-05 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2016-12-22 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2016-12-22 15:25:58 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-01-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-01-27 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-01-27 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-01-05 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-01-05 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-01-05 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2017-01-05 09:50:06 | PLAN DENIED | | | PROVIDE THE SIZE OF ARMOUERS ON THE PLAN. | | | PER SECTION 107 FBC 2014 | | | REFER TO FIRE COMMENTS. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
|