Plan Review Details - Permit 16120749
Plan Review Stops For Permit 16120749
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-04-19 Cont ID  
Sent By shill Date 2017-04-19 Time 16:56 Rev Time 0.00
Received By shill Date 2017-04-19 Time 16:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-04-06 Cont ID  
Sent By shill Date 2017-04-06 Time 12:01 Rev Time 0.00
Received By shill Date 2017-04-06 Time 11:52 Sent To  
Notes
2017-04-06 12:14:45****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. SCOPE NOT CLEAR. THE APPLICATION IS TO "MODIFY
 EXISTING PARKING LOT WITH NEW PAVEMENT, CONCRETE,
 HARDSCAPE, STRIPING & SIGNAGE." AN 11X17 PAGE WITH
 COLORED HATCH MARKS WAS PROVIDED - ALL CURBS, ISLANDS,
 EXTERIOR SIGNAGE (TRAFFIC), SIDEWALKS, PAVEERS, AND
 STRIPING". VALUE ON APPLICATION IS $4,880.
  
 FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS JOB.
 THIS SHOULD BE ITEMIZED AND INCLUDE SQUARE FOOT AREAS.
 THE VALUE OF PREVIOUSLY ISSUED RELATED BUILDING PERMITS
 DID NOT INCLUDE THE WORK PROPOSED.
  
 PLANS SUBMITTED ARE CIVIL PAGES WHICH INCLUDE DRAINAGE
 AND OTHER INFORMATION WHICH DO NOT APPEAR TO BE
 INCLUDED IN THE SCOPE OF THIS APPLICATION.
  
 FBC 107, PROVIDE A PLAN WHICH SHOWS SCOPE AND NATURE OF
 WORK.
  
 2. STRIPING OF THE EXISTING SURFACE PARKING LOT APPEARS
 TO BE INCLUDED IN THE SCOPE OF THIS APPLICATION. FOR
 RE-STRIPE PERMITS, THE FOLLOWING INFORMATION IS
 REQUIRED:
  
 A. A PLAN WHICH SHOWS THE FOLLOWING:
  
 TOTAL NUMBER OF PARKING SPACES
 NUMBER OF ACCESSIBLE SPACES
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 SEE FBC 2014 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2
 (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE
 ROUTE).
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN."
  
 HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 B. FBC 2014 ACCESSIBILITY ADVISORY 502.3, WHERE THE
 ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES,
 MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE
 INDICATE LOCATION ON PLAN.
  
 C. FOR ANY PLANS WHICH ARE NOT PREPARED BY A DESIGN
 PROFESSIONAL (AND THEREFORE SIGNED AND SEALED), THE
 INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE THEIR
 PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107.
  
 3. FBC 107, WHEN RESUBMITTING APPLICANT IS TO PREPARE
 TWO IDENTICAL COLLATED SETS OF PERMIT DOCUMENTS FOR
 PERMIT ISSUANCE.
  
 OLD SHEETS ARE TO BE RETAINED IN THE SUBMITTAL, REMOVED
 FROM THE TWO PERMIT ISSUE SETS, AND THOSE DOCUMENTS
 SHOULD BE MARKED "VOID" OR "OLD SHEETS".
  
 THE TWO COLLATED PERMIT SETS ARE TO INCLUDE ANY
 DOCUMENTS PREVIOUSLY SUBMITTED AND REVIEWED AS WELL AS
 THE NEW DOCUMENTS WHICH SHOULD ADDRESS ALL COMMENTS.
  
 ALL OLD VOIDED SHEETS SHOULD BE MARKED "VOID" AND
 RETAINED IN THE SUBMITTAL. IT IS STRONGLY RECOMMENDED
 THAT ALL VOIDED SHEETS BE RETAINED - DO NOT DISCARD
 VOIDED SHEETS TO LEAVE ONLY ONE COPY OF EACH VOIDED
 PAGE. FAILURE TO RETAIN ALL DOCUMENTS IN THE SUBMITTAL
 PACKAGE MAY RESULT IN PLAN REVIEW DELAYS.
  
 A RESPONSE LETTER STATING HOW EACH ITEM WAS ADDRESSED
 WILL HELP TO EXPEDITE YOUR PLAN REVIEW.
  
 DO NOT REMOVE ANY SHEETS FROM THE PACKAGE. THIS
 PREVIOUSLY PASSED BUILDING, BUT THERE ARE NO PLANS
 STAMPED BY BUILDING SO IT IS NOT CLEAR WHAT WAS
 REVIEWED AND APPROVED.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-03-02 Cont ID  
Sent By skennedy Date 2017-03-02 Time 10:50 Rev Time 0.00
Received By skennedy Date 2017-03-02 Time 10:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-02-24 Cont ID  
Sent By skennedy Date 2017-02-24 Time 10:08 Rev Time 0.00
Received By skennedy Date 2017-02-24 Time 10:08 Sent To  
Notes
2017-02-24 10:14:461ST REVIEW: FBC 2014 5TH ED.
 1ST REVIEW FBC 2014
  
 PLANS ARE INADEQUATE. YOU SHOULD SUBMIT SIGNED AND SEAL
 PLANS CONSISTENT WITH PREVIOUSLY APPROVED SITE PLANS
 AND CIVIL PLANS INCLUDING ALL SURFACE STRIPING AND
 ACCESSIBILITY DETAILS. ALL YOU HAVE SUBMITTED IS AN
 AREIAL PHOTOGRAPH ESSIENTIALLY SHOWING NOTHING.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2017-03-02 Cont ID  
Sent By skennedy Date 2017-03-02 Time 10:49 Rev Time 0.00
Received By skennedy Date 2017-03-02 Time 10:49 Sent To  
Notes
2017-03-02 10:50:22MET WITH MGONZALES. HE INDICATED OK BUT THAT HIS REVIEW
 AND INSPECTIONS WILL BE UNDER THE ENGINEERING
 INFRASTRUCTURE PERMIT.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2017-02-20 Cont ID  
Sent By mgonzale Date 2017-02-20 Time   Rev Time 1.00
Received By mgonzale Date 2017-02-20 Time   Sent To B
Notes
2017-02-20 12:25:10ADDRESS PLANNINGS COMMENTS
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF
 WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE."
 FOR MORE INFORMATION REFER TO THE LINK BELOW:
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-04-19 Cont ID  
Sent By shill Date 2017-04-19 Time 16:56 Rev Time 0.00
Received By shill Date 2017-04-17 Time 13:19 Sent To  
Notes
2017-04-18 13:19:47RESUB ROUTED TO SHILL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-06 Cont ID  
Sent By shill Date 2017-04-06 Time 12:15 Rev Time 0.00
Received By shill Date 2017-03-21 Time 10:56 Sent To  
Notes
2017-03-22 10:56:41RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-22 Cont ID  
Sent By lmarchan Date 2017-03-22 Time 10:56 Rev Time 0.00
Received By lmarchan Date 2017-03-02 Time 10:49 Sent To Z
Notes
2017-03-02 11:14:23CHARLOTTE DECIDED TO CHECK OUT A SET WHILE
 RE-SUBMITTING. SAK
2017-03-02 10:51:10GET [LANS TO ME TO STAMP UP PRIOR TO PROCESSING OUT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status F Date 2017-02-24 Cont ID  
Sent By skennedy Date 2017-02-24 Time 10:08 Rev Time 0.00
Received By skennedy Date 2016-12-21 Time 13:36 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-03-31 Cont ID  
Sent By eschneid Date 2017-03-31 Time 14:46 Rev Time 0.50
Received By eschneid Date 2017-03-31 Time 14:46 Sent To  
Notes
2017-03-23 08:33:40ROUTED TO ERIC SCHNEIDER

Review Stop Z ZONING
Rev No 1 Status F Date 2017-01-12 Cont ID  
Sent By skennedy Date 2017-02-24 Time 10:08 Rev Time 0.75
Received By eschneid Date 2017-01-12 Time 13:30 Sent To ENG
Notes
2017-01-12 14:21:03FAILED
  
 1) PLEASE CLARIFY WHAT IS INCLUDED ON THIS PERMIT. IT
 STATES THAT IT IS TO MODIFY THE EXISTING PARKING LOT.
 DOES THAT MEAN IT IS ONLY FOR THE AREA WEST OF THE NEW
 PARKING GARAGE? IF SO, PLEASE HIGHLIGHT THE AREA AND
 REMOVE ANY SHEETS THAT DO NOT SHOW AREAS COVERED BY
 THIS PERMIT.
  
 2) WHAT HARDSCAPE (PLAZA PAVERS?) AND SIGNAGE ARE BEING
 INCLUDED WITH THIS PERMIT?
  
 3) THERE HAVE BEEN SOME MINOR CHANGES TO THE CIVIL
 PLANS SINCE THE APPROVAL OF THE MINOR AMENDMENT, SO
 PRIOR TO C.O. OF THE GARAGE, A MINOR PD AMENDMENT SHALL
 BE SUBMITTED TO THE CITY'S PLANNING DIVISION TO REFLECT
 THE APPROVED AS-BUILT CONDITIONS. THESE CHANGES PASS
 THE ZONING REVIEW.
  
 4) THE SUBMITTED PLANS DO NOT MATCH THE ARCHITECTURAL
 SITE PLAN SUBMITTED AS PART OF THE GENERATOR AND
 BICYCLE RACK PERMITS OR THE LANDSCAPE PERMIT BASE
 PLANS. ALL PLANS SHALL SHOW THE SAME CONDITIONS. PLEASE
 NOTE THAT STAFF IS NOT APPROVING THE CONFIGURATION OF
 THE BICYCLE RACKS THAT ARE PROPOSED FOR INSTALLATION
 ADJACENT TO THE WESTERN EDGE OF THE ENTRY PLAZA
 (COMMENTS UNDER PERMIT 16120370), SO CHANGING THE CIVIL
 PLANS TO MATCH THE UNAPPROVED ARCHITECTURAL SITE PLAN
 IS NOT RECOMMENDED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved