Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-04-17 Cont ID  
Sent By cthroop Date 2017-04-17 Time 13:02 Rev Time 0.00
Received By cthroop Date 2017-04-17 Time 12:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-03-28 Cont ID  
Sent By cthroop Date 2017-03-28 Time 16:23 Rev Time 0.00
Received By cthroop Date 2017-03-28 Time 16:22 Sent To  
Notes
2017-03-28 16:30:38BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. FOUNDATION REQUIRED PER ACI 318. MIN. 8" X 10" W/2
 #5 CONT.
 2. VERTICAL REINFORCEMENT PER TABLE 1807.2.4. 1 #4 AT
 EACH END/OPENING AND 72" O.C. KEEP REBAR TO SOIL SIDE
 OF BLOCK AND GROUT CELL.
 3. LOCATION - RETAINING WALL MAY BUTT UP TO BUT NOT
 ENCROACH EXISTING SIDEWALK. THIS APPLIES TO FOUNDATION
 AND CAP BLOCK.
 4. PLEASE SEE RED LINED PLANS FOR CLARIFICATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-01-09 Cont ID  
Sent By cthroop Date 2017-01-09 Time 14:13 Rev Time 0.00
Received By cthroop Date 2017-01-09 Time 14:13 Sent To  
Notes
2017-01-09 14:16:28BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IDENTIFY LOCATION OF WALL ON SITE PLAN/SURVEY.
 2. PROVIDE DETAIL OF FOUNDATION AND WALL.
 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE PLAN PER FBC
 107.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-17 Cont ID  
Sent By cthroop Date 2017-04-17 Time 13:02 Rev Time 0.00
Received By cthroop Date 2017-04-11 Time 11:17 Sent To  
Notes
2017-04-12 11:17:43RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-03-28 Cont ID  
Sent By cthroop Date 2017-03-28 Time 16:23 Rev Time 0.00
Received By cthroop Date 2017-03-21 Time 11:22 Sent To  
Notes
2017-03-22 11:22:59RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-09 Cont ID  
Sent By cthroop Date 2017-01-09 Time 14:13 Rev Time 0.00
Received By cthroop Date 2016-12-20 Time 13:52 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2017-04-14 Cont ID  
Sent By njwira Date 2017-04-14 Time 18:52 Rev Time 0.00
Received By njwira Date 2017-04-12 Time 15:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-03-27 Cont ID  
Sent By njwira Date 2017-03-27 Time 16:31 Rev Time 0.00
Received By njwira Date 2017-03-23 Time 08:32 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-12-29 Cont ID  
Sent By cthroop Date 2017-01-09 Time 14:13 Rev Time 0.00
Received By njwira Date 2016-12-21 Time 17:29 Sent To B
Notes
2016-12-29 16:48:4612/29/16- FAILED
  
 SF-7
  
 WHAT IS THE HEIGHT OF THE FENCE
 WHAT IS THE MATERIAL OF THE FENCE
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  