Plan Review Details - Permit 16120622
Plan Review Stops For Permit 16120622
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-06 Cont ID  
Sent By vperez Date 2017-02-06 Time 09:42 Rev Time 0.00
Received By vperez Date 2017-02-06 Time 09:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-12-27 Cont ID  
Sent By vperez Date 2016-12-27 Time 13:23 Rev Time 0.00
Received By vperez Date 2016-12-27 Time 13:23 Sent To  
Notes
2016-12-27 13:24:23ADDRESS FIRE COMMENTS FOR AN ELECTRICAL APPROVAL
  
 V PEREZ

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-02-02 Cont ID  
Sent By pleduc Date 2017-02-02 Time   Rev Time 0.00
Received By pleduc Date 2017-02-02 Time 14:53 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-12-21 Cont ID  
Sent By pleduc Date 2016-12-21 Time   Rev Time 0.00
Received By pleduc Date 2016-12-21 Time 09:51 Sent To E
Notes
2016-12-21 10:52:25THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE SUBMITTED PACKET DOES NOT INCLUDE VOLTAGE DROP,
 BATTERY CALCULATIONS AND WIRING DIAGRAM FOR ALL
 DEVICES.
  
 PLEASE PROVIDE THE ABOVE PER NFPA 101 CHAPTER 9,
 BUILDING SERVICE AND FIRE PROTECTION EQUIPMENT
  
 9.6.1.3 A FIRE ALARM SYSTEM REQUIRED FOR LIFE SAFETY
 SHALL BE INSTALLED, TESTED, AND MAINTAINED IN
 ACCORDANCE WITH THE APPLICABLE REQUIREMENTS OF NFPA 70,
 NATIONAL ELECTRICAL CODE, AND NFPA 72, NATIONAL FIRE
 ALARM AND SIGNALING CODE, UNLESS IT IS AN APPROVED
 EXISTING INSTALLATION, WHICH SHALL BE PERMITTED TO BE
 CONTINUED IN USE.
  
  
 PLEASE PROVIDE THE ABOVE REQUIRED DOCUMENTATION.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-06 Cont ID  
Sent By vperez Date 2017-02-06 Time 09:42 Rev Time 0.00
Received By vperez Date 2017-02-06 Time 09:42 Sent To  
Notes
2017-01-30 15:51:43RESUB ROUTED TO FIRE INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-12-27 Cont ID  
Sent By vperez Date 2016-12-27 Time 13:24 Rev Time 0.00
Received By vperez Date 2016-12-27 Time 13:24 Sent To  
Notes
2016-12-16 15:03:27ROUTED TO FIRE INBOX