Plan Review Details - Permit 16120583
Plan Review Stops For Permit 16120583
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-02-13 Cont ID  
Sent By jwitmer Date 2017-02-13 Time 07:28 Rev Time 0.00
Received By jwitmer Date 2017-02-13 Time 06:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-12-22 Cont ID  
Sent By jwitmer Date 2016-12-22 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2016-12-22 Time 13:47 Sent To  
Notes
2016-12-22 15:28:41BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16120583
 ADD: 6527 N. JOG RD.
 CONT: ONE CALL PROPERTY SERVICES, INC.
 TEL: 561-692-6277
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. DEC. 22/ 2016
 ACTION: DENIED
  
 1) SHEET 01 SHOWS THE NEW WALLS OF THE PROPOSED LOCKER
 ROOM AS A PARTITION TYPE P1. PLEASE PROVIDE WHERE IN
 THE PLANS A P1 PARTITION IS FOUND. SHEET A-03 DETAIL #
 6 SHOWS THE SAME WALL AS A 1 HOUR PARTITION, A UL
 LISTING OF U419. UL LISTING U419 IS A 1 HOUR FIRE RATED
 NON-BEARING PARTITION. SHEET 03 DETAILS 6 & 7 BOTH SHOW
 A PLYWOOD UNDERLAYMENT AND SECONDARY SHEET OF ? INCH
 LEVLEROCK FLOOR UNDERLAYMENT.
  
 2) THE SHEET A03 DETAIL SHOWS A FLOOR / CEILING
 ASSEMBLY LISTED AS UL LISTING L524, PLEASE PROVIDE
 WHICH SYSTEM NUMBER THIS SERIES OF COMPONENTS IS? I
 DON?T FIND THESE COMPONENTS IN THE UL LISTING BOOK FOR
 A 1 HOUR FIRE RATING FLOOR/ CEILING ASSEMBLY. FBC-B
 TABLE 707.3.10.
  
 ? 3) SHEET A04 DETAIL # 6 SHOWS A NEW LADDER USED TO
 GAIN ACCESS TO THE EXISTING MECHANICAL PLATFORM AND
 EXISTING CATWALK. PLEASE SHOW COMPLIANCE WITH 2014
 FBC-B 1509.6.4 EQUIPMENT AND APPLIANCES ON ELEVATED
 STRUCTURES.
 PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED
 ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN
 CRITERIA:
 3.1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET OR
 ROOF EDGE NOT LESS THAN 30 INCHES (762 MM).
 3.2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14
 INCHES (356 MM) ON CENTER.
 3.3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN
 6-INCHES (152 MM) DEEP.
 3.4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM)
 BETWEEN RAILS.
 3.5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM)
 DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND
 (136.1 KG) LOAD.
 3.6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE
 PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF
 WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2).
 3.7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY
 APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE
 REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610
 MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR
 SERVICE PLATFORMS.
  
 4) SHEET A-02 SHOWS CERAMIC TILE ON THE RESTROOM WALLS
 BUT THERE IS NO MENTION OF THE TYPE OF BACKING TO BE
 INSTALLED. PLEASE SHOW COMPLIANCE WITH 2014 FBC-B
 2509.2 BASE FOR TILE. GLASS MAT WATER-RESISTANT GYPSUM
 BACKING PANELS, DISCRETE NONASBESTOS FIBER-CEMENT
 INTERIOR SUBSTRATE SHEETS OR NONASBESTOS FIBER-MAT
 REINFORCED CEMENTITIOUS BACKER UNITS IN COMPLIANCE WITH
 ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE
 USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS
 AND WALL AND CEILING PANELS IN SHOWER AREAS.
 WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A
 BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840 AND
 MANUFACTURER RECOMMENDATIONS. REGULAR GYPSUM WALLBOARD
 IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL
 AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR ASTM C 840.
  
 5) SHEET A2 DETAILS A7, A8 & 08 ALL SHOW THE ACCESSIBLE
 WATER CLOSET GRAB BARS ARE SET AT 36 INCHES CENTERLINE
 OF THE GRAB BAR. PLEASE NOTE IN THE 2014
 FBC-ACCESSIBILITY CODE 609.4 THE GRAB BARS ARE MEASURED
 FROM FINISH FLOOR TO THE TOP OF THE GRASPING SURFACE,
 NOT CENTER LINED.
 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-02-07 Cont ID  
Sent By rlecky Date 2017-02-07 Time 13:40 Rev Time 0.00
Received By rlecky Date 2017-02-07 Time 13:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-01-10 Cont ID  
Sent By rlecky Date 2017-01-10 Time 14:50 Rev Time 0.00
Received By rlecky Date 2017-01-10 Time 14:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-02-10 Cont ID  
Sent By pleduc Date 2017-02-10 Time   Rev Time 0.00
Received By pleduc Date 2017-02-10 Time 07:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-12-22 Cont ID  
Sent By pleduc Date 2016-12-22 Time   Rev Time 0.00
Received By pleduc Date 2016-12-22 Time 11:59 Sent To  
Notes
2016-12-22 12:21:10THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET A 01 - THERE IS AN INDICATION THAT THE
 BUILDING IS FULLY SPRINKLERED. THERE IS NO INDICATION
 OF FIRE SPRINKLER OR FIRE ALARM WORK BEING UNDER
 SEPARATE PERMIT AND SHOP DRAWING BY CERTIFIED LIFE
 SAFETY CONTRACTORS.
  
 PLEASE PROVIDE AN APPLICABLE NOTE WITH THE ABOVE
 REQUIREMENT.
  
  
  
 2) SHEET A 03 & E 2 - THERE IS INDICATION OF A CARD
 READER SYSTEM. THE CARD READER SYSTEM SHALL BE UNDER
 SEPARATE PERMIT AND NOT APPROVED WITH THIS PERMIT.
  
 PLEASE PROVIDE AN APPLICABLE NOTE.
  
  
  
  
 3) SHEET A 04 - A NEW LADDER TO SERVICE THE CATWALK IS
 INDICATED. THIS LADDER IS A FIRE ESCAPE LADDER FOR
 THOSE USING THE CAT WALK. THIS LADDER SHALL COMPLY WITH
 THE REQUIREMENTS OF NFPA 101, CHAPTER 7, MEANS OF
 EGRESS.
  
  
 7.2.9 FIRE ESCAPE LADDERS.
 7.2.9.1 GENERAL. FIRE ESCAPE LADDERS COMPLYING WITH
 7.2.9.2 AND
 7.2.9.3 SHALL BE PERMITTED IN THE MEANS OF EGRESS ONLY
 WHERE PROVIDING ONE OF THE FOLLOWING:
 (1) ACCESS TO UNOCCUPIED ROOF SPACES AS PERMITTED IN
 7.2.8.3.4
 (2) SECOND MEANS OF EGRESS FROM STORAGE ELEVATORS AS
 PERMITTED IN CHAPTER 42
 (3) MEANS OF EGRESS FROM TOWERS AND ELEVATED PLATFORMS
 AROUND MACHINERY OR SIMILAR SPACES SUBJECT TO OCCUPANCY
 NOT TO EXCEED THREE PERSONS WHO ARE ALL CAPABLE OF
 USING THE LADDER
 (4) SECONDARY MEANS OF EGRESS FROM BOILER ROOMS OR
 SIMILAR SPACES SUBJECT TO OCCUPANCY NOT TO EXCEED THREE
 PERSONS WHO ARE ALL CAPABLE OF USING THE LADDER
 (5) ACCESS TO THE FINISHED GROUND LEVEL FROM THE LOWEST
 BALCONY OR LANDING OF A FIRE ESCAPE STAIR FOR SMALL
 BUILDINGS AS PERMITTED IN 7.2.8.4 WHERE APPROVED BY THE
 AUTHORITY HAVING JURISDICTION
  
 7.2.9.2 CONSTRUCTION AND INSTALLATION.
 7.2.9.2.1 FIRE ESCAPE LADDERS SHALL COMPLY WITH ANSI
 A14.3, SAFETY REQUIREMENTS FOR FIXED LADDERS, UNLESS
 ONE OF THE FOLLOWING CRITERIA IS MET:
 (1) APPROVED EXISTING LADDERS COMPLYING WITH THE
 EDITION OF THIS CODE THAT WAS IN EFFECT WHEN THE
 LADDERS WERE INSTALLED SHALL BE PERMITTED.
 (2) INDUSTRIAL STAIRS COMPLYING WITH THE MINIMUM
 REQUIREMENTS FOR FIXED STAIRS OF ANSI/ASSE A1264.1,
 SAFETY REQUIREMENTS FOR WORKPLACE FLOOR AND WALL
 OPENINGS, STAIRS AND RAILING SYSTEMS, SHALL BE
 PERMITTED WHERE FIRE ESCAPE LADDERS ARE PERMITTED IN
 ACCORDANCE WITH CHAPTER 40.
 7.2.9.2.2 LADDERS SHALL BE INSTALLED WITH A PITCH THAT
 EXCEEDS 75 DEGREES.
 7.2.9.3 ACCESS. THE LOWEST RUNG OF ANY LADDER SHALL NOT
 BE MORE THAN 12 IN. (305 MM) ABOVE THE LEVEL OF THE
 SURFACE BENEATH IT.
  
 PLEASE PROVIDE THE APPLICABLE DETAILED DRAWING
 INDICATING COMPLIANCE WITH THE ABOVE NOTED CODES
  
  
  
 4) SHEET E 2 - PLEASE PROVIDE AN ADDITIONAL EXIT SIGN
 AT THE END OF THE NEW CORRIDOR AT THE OPEN SPACE
 LEADING TO THE EXISTING EXIT.
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-02-28 Cont ID  
Sent By ccole Date 2017-02-28 Time 09:18 Rev Time 0.00
Received By ccole Date 2017-02-24 Time 14:43 Sent To  
Notes
2017-02-27 14:44:07RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-02-15 Cont ID  
Sent By gjohnson Date 2017-02-15 Time 16:14 Rev Time 0.00
Received By gjohnson Date 2017-02-03 Time 15:04 Sent To  
Notes
2017-02-03 15:04:37B24

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-13 Cont ID  
Sent By gjohnson Date 2017-01-13 Time 16:02 Rev Time 0.00
Received By gjohnson Date 2016-12-15 Time 10:34 Sent To  
Notes
2016-12-16 10:34:23B26

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-12-22 Cont ID  
Sent By jwitmer Date 2016-12-22 Time 14:32 Rev Time 0.00
Received By jwitmer Date 2016-12-22 Time 13:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-02-28 Cont ID  
Sent By ccole Date 2017-02-28 Time 09:18 Rev Time 0.00
Received By ccole Date 2017-02-28 Time 09:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-02-08 Cont ID  
Sent By ccole Date 2017-02-08 Time 10:52 Rev Time 0.00
Received By ccole Date 2017-02-08 Time 10:52 Sent To  
Notes
2017-02-08 10:57:322ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16120583
 2/8/17
  
 1) PROVIDE AN EQUIPMENT SCHEDULE FOR EF-3 THAT INCLUDES
 THE MAKE AND MODEL NUMBER AND CFM CAPACITY.
  
 2) PLEASE PROVIDE AN EXHAUST INLET IN THE NEW LOCKER
 ROOM- SEE SECTION 502.1.1
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-12-28 Cont ID  
Sent By ccole Date 2016-12-28 Time 09:36 Rev Time 0.00
Received By ccole Date 2016-12-28 Time 09:36 Sent To  
Notes
2016-12-28 09:41:461ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16120583
 12/28/16
  
 1) SHEET A-01 & M-1: PLEASE ADJUST THE EXHAUST
 CALCULATION FOR THE LOCKER ROOM BASED ON THE FLOOR PLAN
 DIMENSIONS. SHOW THE LOCATION OF EF-3 AND CLARIFY WHICH
 AREAS IT IS SERVING AND IT'S CFM CAPACITY.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-02-15 Cont ID  
Sent By gjohnson Date 2017-02-15 Time 16:14 Rev Time 0.00
Received By gjohnson Date 2017-02-15 Time 15:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-01-13 Cont ID  
Sent By gjohnson Date 2017-01-13 Time 15:48 Rev Time 0.00
Received By gjohnson Date 2017-01-13 Time 15:48 Sent To  
Notes
2017-01-13 16:02:191ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHT. A-02 GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES (840 MM) MINIMUM AND 36
 INCHES (915 MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED
 TO THE TOP OF THE GRIPPING SURFACE. PER FBC ACC 609.4
  
 2. SHT. A-02 FLUSH CONTROLS SHALL BE LOCATED ON THE
 OPEN SIDE OF THE WATER CLOSET. FBC ACC 604.6
  
 3, SHT. A-02 THE OUTLET OF THE TOILET PAPER DISPENSER
 SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 INCHES (1220
 MM) MAXIMUM ABOVE THE FINISH FLOOR . FBC ACC 604.7
  
  
  