Plan Review Details - Permit 16120571
| Plan Review Stops For Permit 16120571 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-21 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-21 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-12-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-17 |
Time |
05:04 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-17 |
Time |
04:21 |
Sent To |
|
|
| Notes |
| 2016-12-17 04:59:29 | 1) INDICATE THE PSI OF THE SYSTEM ON BOTH DRAWINGS. FBC | | | RES. SEC. G2413.2. . | | | 2) SUBMIT TWO COPIES OF THE SIZING TABLES USED IN THE | | | DESIGN FOR THIS GAS SYSTEM OR PLACE A NOTE ON BOTH SETS | | | OF PLANS LISTING THE SIZING TABLES FROM THE GAS CODE | | | THAT WERE USED IN THE DESIGN OF THIS SYSTEM. FGC | | | SEC.402.3, FBCR SEC. G 2413.3. | | | 3)SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014 | | | FBC-FUEL GAS CODE SEC.304.1 OR 2014 FBC-RES. SEC. G | | | 2407. | | | 4) THE BRANCHES FOR THE GENERATOR, RANGE, FIREPLAC POOL | | | HEATER AND GRILL ARE SHOWN ON THE RISER AS BEING ONLY | | | ONE AND TWO FEET IN LENGTH WHICH DOESN'T MAKE SENSE AS | | | THIS WOULD MEAN THEY ARE IN VERY CLOSE PROXIMITY OF | | | EACH OTHER. THE TOTAL LENGTH OF EACH BRANCH MUST BE | | | INCLUDED IN THE TOTAL DISTANCE FROM THE METER TO THE | | | MOST REMOTE OUTLET AS THIS WILL INCREASE THE DISTANCE. | | | SHOW THE CORRECT DISTANCE OF THE APPLIANCE FROM THE | | | MAIN TO EACH OUTLET. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-21 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-21 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-17 |
Time |
05:04 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-15 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2016-12-16 10:04:57 | PLUMB <5K |
|
|
|