Plan Review Details - Permit 16120521
Plan Review Stops For Permit 16120521
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-01-25 Cont ID  
Sent By jwitmer Date 2017-01-25 Time 08:46 Rev Time 0.00
Received By jwitmer Date 2017-01-25 Time 07:45 Sent To  
Notes
2017-01-25 08:46:48BUILDING PLAN REVIEW
 W. P. B. REVISION: 16120521
 W. P. B. PERMIT: 16050444
 ADD: 3224 S. DIXIE HWY.
 CONT: ATLANTIC ENGINEERING SERVICES
 TEL: 561-358-4140
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. JAN. 25/2017
 ACTION: BUILDING PROVISO/ RED LINED
 SPOKE WITH ENG. IMTIAZ AHMED P.E.
  
 1) PROVISO/ RED LINED A1, A2 & L.S. SHEETS! BOTH SHEETS
 A2 AND LS1 ARE MISSING THE 2 HOUR RATING BETWEEN
 OCCUPANCIES SEE WALL BETWEEN THE OFFICE AND UNIT # 1.
 SEE 2014 FBC-B TABLE 508.4.
  
 2) PROVISO/ RED LINED A1, A2 & L.S. SHEETS!
 2014 FBC-B 1009.15 HANDRAILS. STAIRWAYS SHALL HAVE
 HANDRAILS ON EACH SIDE AND SHALL COMPLY WITH SECTION
 1012.
  
 1012.6 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE
 NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL
 EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER.
  
 2014 FBC-ACCESSIBILITY CODE 307.3 POST MOUNTED OBJECTS.
 WHERE THE HANDRAIL ON THE OUTER SIDE OF THE STAIRS IS
 REQUIRED TO HAVE THE HORIZONTAL EXTENSION OF 12 INCHES
 IT WILL NEED TO RETURN UPON ITSELF NO HIGHER THAN 27
 INCHES FOR THE LIMITS OF PROTRUDING OBJECTS.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-01-05 Cont ID  
Sent By shill Date 2017-01-05 Time 17:16 Rev Time 0.00
Received By jwitmer Date 2017-01-05 Time 15:58 Sent To  
Notes
2017-01-05 17:09:14BUILDING PLAN REVIEW
 W. P. B. REVISION: 16120521
 W. P. B. PERMIT: 16050444
 ADD: 3224 S. DIXIE HWY.
 CONT: ATLANTIC ENGINEERING SERVICES
 TEL: 561-358-4140
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JAN. 05/2017
 ACTION: DENIED
  
 1) BOTH SHEETS A2 AND LS1 ARE MISSING THE 2 HOUR RATING
 BETWEEN OCCUPANCIES SEE WALL BETWEEN THE OFFICE AND
 UNIT # 1. SEE 2014 FBC-B TABLE 508.4.
  
 2) FROM THE 2ND PLAN REVIEW OF THE ISSUED PLAN SET OF
 DOCUMENTS, SEE FIRES PROVISO ON THE REAR STEPS
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STEPS. NOT
 INCORPORATED IN THIS SET OF PLANS. 2014 FBC-B 1009.15
 HANDRAILS. STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE
 AND SHALL COMPLY WITH SECTION 1012.
  
 1012.6 HANDRAIL EXTENSIONS.
 HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT OR RAMP RUN. WHERE HANDRAILS ARE
 NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL
 EXTEND HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER.
  
 2014 FBC-ACCESSIBILITY CODE 307.3 POST MOUNTED OBJECTS.
 WHERE THE HANDRAIL ON THE OUTER SIDE OF THE STAIRS IS
 REQUIRED TO HAVE THE HORIZONTAL EXTENSION OF 12 INCHES
 IT WILL NEED TO RETURN UPON ITSELF NO HIGHER THAN 27
 INCHES FOR THE LIMITS OF PROTRUDING OBJECTS.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-01-05 Cont ID  
Sent By mvaldes Date 2017-01-05 Time 12:06 Rev Time 0.00
Received By rlecky Date 2017-01-05 Time 10:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-01-18 Cont ID  
Sent By pleduc Date 2017-01-18 Time   Rev Time 0.00
Received By pleduc Date 2017-01-17 Time 10:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-12-21 Cont ID  
Sent By pleduc Date 2016-12-21 Time   Rev Time 0.00
Received By pleduc Date 2016-12-21 Time 13:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-02-03 Cont ID  
Sent By hmoser Date 2017-02-03 Time 14:06 Rev Time 0.00
Received By hmoser Date 2017-01-31 Time 10:26 Sent To  
Notes
2017-02-01 10:27:11RESUB ROUTED TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-01-25 Cont ID  
Sent By jwitmer Date 2017-01-25 Time 08:47 Rev Time 0.00
Received By jwitmer Date 2017-01-09 Time 13:25 Sent To  
Notes
2017-01-10 13:25:37C15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-09 Cont ID  
Sent By hmoser Date 2017-01-09 Time 11:18 Rev Time 0.00
Received By hmoser Date 2016-12-14 Time 14:25 Sent To  
Notes
2016-12-15 14:25:14C15

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-02-03 Cont ID  
Sent By hmoser Date 2017-02-03 Time 13:55 Rev Time 0.00
Received By hmoser Date 2017-02-03 Time 13:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-01-20 Cont ID  
Sent By hmoser Date 2017-01-20 Time 11:01 Rev Time 0.00
Received By hmoser Date 2017-01-20 Time 10:56 Sent To  
Notes
2017-01-20 11:01:391) PROVIDE ENERGY CALCULATIONS, PROVIDE MORE
 INFORMATION ON MECHANICAL PLAN.
 PER SECTION 107 FBC 2014
 2) PROVIDE DUCT SIZE, GRILL SIZE AND CFM ON PLAN
 3) SHOW RETURN AIR ON PLANS.
 PER SECTION 107 FBC 2014
  
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-01-09 Cont ID  
Sent By jvalido Date 2017-01-09 Time 11:18 Rev Time 0.00
Received By hmoser Date 2017-01-09 Time 10:56 Sent To  
Notes
2017-01-09 11:17:56PLAN DENIED
 PLEASE CLOUD MECHANICAL REVISIONS. REVISION WAS
 SUBMITTED FOR MECHANICAL. CANT FIND THE CHANGES ON
 MECHANICAL PAGE.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-02-02 Cont ID  
Sent By gjohnson Date 2017-02-02 Time 10:35 Rev Time 0.00
Received By gjohnson Date 2017-02-02 Time 10:35 Sent To  
Notes
2017-02-02 10:36:35NO PLUMBING UNDER THIS REV GPJ

Review Stop P PLUMBING
Rev No 1 Status N Date 2017-02-03 Cont ID  
Sent By tklarge Date 2017-01-24 Time 10:35 Rev Time 0.00
Received By gjohnson Date 2017-01-24 Time 10:20 Sent To  
Notes
2017-01-24 13:04:531ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PLEASE INDICATE ON PLANS CHANGES TO THE PLUMBING
 SYSTEM BY CLOUDING OR NOTES ON THE PLAN. PER WPB AMEND
 TO FBC 107.2.1

Review Stop Z ZONING
Rev No 2 Status P Date 2017-01-17 Cont ID  
Sent By njwira Date 2017-01-17 Time 09:35 Rev Time 0.00
Received By njwira Date 2017-01-17 Time 09:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-01-05 Cont ID  
Sent By njwira Date 2017-01-05 Time 09:15 Rev Time 0.00
Received By njwira Date 2016-12-21 Time 17:23 Sent To  
Notes
2017-01-05 09:17:421/5/17- FAILED
  
 1. PLEASE INDICATE IN THE PLANS THAT MORE THAN 50% OF
 THE BUILDING IS NOT FOR WINE COOLERS.
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  
  
  