Plan Review Details - Permit 16120403
Plan Review Stops For Permit 16120403
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-01-18 Cont ID  
Sent By rmcdouga Date 2017-01-18 Time 17:52 Rev Time 0.00
Received By rmcdouga Date 2017-01-18 Time 17:52 Sent To  
Notes
2017-01-18 17:52:40PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE COMPLETE SCOPE OF WORK ON THE PLANS. FBC
 107.2.1
  
 2) PLEASE CLARIFY THE AMOUNT OF SIDING THAT WILL BE
 REPLACE. IF ALL SIDING WILL BE REPLACED, SPECIFY THIS
 ON THE PLANS. SPECIFY THE AREAS THAT ARE TO BE
 REPLACED, UNLESS ALL OF IT IS BEING REPLACED. FBC
 107.2.1
  
 3) SPECIFY THE TYPE OF SIDING THAT WILL BE USED TO
 REPLACE THE EXISTING. IF CEMENT BOARD, SUCH AS,
 HARDI-PLANK OR OTHER MANUFACTURED PRODUCT IS USED
 SUBMIT TWO SETS OF THE PRODUCT APPROVALS AS REQUIRED BY
 FAC 61G20-3.001
  
 4) SPECIFY THE REQUIRED DESIGN PRESSURES FOR THE NEW
 EXTERIOR DOORS ON THE PLANS. FBC-R301.2.1
  
 5) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2017-01-05 Cont ID  
Sent By fmittner Date 2017-01-05 Time 09:26 Rev Time 0.00
Received By fmittner Date 2017-01-05 Time 09:26 Sent To  
Notes
2017-01-05 09:32:46THIS IS A CONTRIBUTING STRUCTURE T THE NORTHWEST
 HISTORIC DISTRICT. APPLCIANT HAS NOT DEMONSTARTED THE
 NEED FOR SIDING REPLACEMENT AND PLANS DO NOT INDICATE
 THAT NEW WINDOWS SHALL REPLCIATE THE ORIGINALS.
  
 LEFT VM WITH O/B JANICE CRIBBS AT 383-0502 ON 1/5/17.
  
 QUESTIONS CONTACT FRIEDERIKE MITTNER, CITY HSITORIC
 PRESERVATION PLANNER AT 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-18 Cont ID  
Sent By rmcdouga Date 2017-01-18 Time 18:11 Rev Time 0.00
Received By rmcdouga Date 2016-12-12 Time 13:52 Sent To  
Notes
2016-12-22 13:52:55R10

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-01-18 Cont ID  
Sent By rmcdouga Date 2017-01-18 Time 18:11 Rev Time 0.00
Received By rmcdouga Date 2017-01-18 Time 17:52 Sent To  
Notes
2017-01-18 18:11:33PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY PLUMBING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) CLARIFY THE SCOPE OF PLUMBING WORK BY PROVIDING A
 DETAILED LIST OF THE WORK ON THE PLANS. SPECIFY THE
 AREAS WHERE THE WATER SUPPLY PIPING OR DRAIN PIPING
 WILL BE REPLACED. SPECIFY WHICH FAUCETS OR FIXTURES
 WILL BE REPLACED. FBC 107.2.1
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-01-05 Cont ID  
Sent By fmittner Date 2017-01-05 Time 09:26 Rev Time 0.00
Received By fmittner Date 2017-01-05 Time 09:26 Sent To  
Notes
***NONE***