Plan Review Details - Permit 16120292
| Plan Review Stops For Permit 16120292 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-12 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-12 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2016-12-12 13:52:04 | SHREET A2.0 DETAIL WEST WING RESTROOM | | | BUILDING PROVISO: | | | 2014 FBC-ACCESSIBILITY CODE | | | 604.3.1 SIZE. CLEARANCE AROUND A WATER | | | CLOSET SHALL BE 60 INCHES (1525 MM) MINIMUM MEASURED | | | PERPENDICULAR | | | FROM THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM | | | MEASURED PER | | | PENDICULAR FROM THE REAR WALL. | | | 604.3.2 OVERLAP. | | | THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE | | | PERMITTED TO | | | OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, | | | DISPENSERS, SANITARY NAPKIN | | | DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, | | | CLEAR FLOOR SPACE AND | | | CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING | | | SPACE. NO OTHER | | | FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE | | | REQUIRED WATER CLOSET | | | CLEARANCE. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-12-14 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-12-14 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-12-14 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-12-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-12-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-12-21 |
Time |
14:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-28 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-08 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-12 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-12 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-19 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-19 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-12-13 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-12-13 |
Time |
05:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-12-15 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |