Plan Review Details - Permit 16111261
Plan Review Stops For Permit 16111261
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-08-04 Cont ID  
Sent By shill Date 2017-08-04 Time 15:44 Rev Time 0.00
Received By shill Date 2017-08-04 Time 15:03 Sent To  
Notes
2017-08-04 15:09:30****PROVISOS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. BUILDING PROVISO: KAYKAN SOFFIT PRODUCT APPROVAL,
 INDICATE WHICH PRODUCT AND INSTALLATION METHOD IS
 PROPOSED (DRAWING PAGE 1 OF 15). SUBMIT TO BUILDING
 DIVISION PRIOR TO INSTALLATION.
  
 2. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB, FBC 109. THIS MAY BE SENT VIA EMAIL. THE
 PERMIT WILL NOT BE ISSUED UNTIL THIS IS ADDRESSED.
  
 6. PRIOR TO INSTALLATION, SUBMIT TO BUILDING DIVISION
 FOR REVIEW:
  
 PROVIDE TEST REPORTS FOR THE FLOORING UNDERLAYMENT
 ACOUSTIC INSULATION:
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492.
  
 C. FBC B 720.2 OR 603.1, PROVIDE TEST DATA IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 (FLAME SPREAD).
  
  
 *****************************************
 16111261 BLDG 1 (NORTH)
 16111265 BLDG 2
 16111259 CLUBHOUSE
  
 16111261 BUILDING DATA FOR C.O./REPORTING
 USC-404 TYPE 434 - ALT RESIDENTIAL
 SQUARE FEET - 69509
  
 CONSTRUCTION TYPE: 14-2-B
 UNITS:
 FLOORS: 4
 BEDROOMS:
 ROOMS:
 SQ FT LIVABLE: 69509
 SQ FT FOOTPRINT: 18480
 SQ FT ROOF: 18480
  
 SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF
 KNOWN):
 SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN):
 XX.XX
 SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN:
 XX.XX
 OCC LOAD:
 PROP USE: APARTMENT
 SPRINKLER SYS? Y
 SPRK REQ'D? Y
 BATHRMS:
  
 BLDG CODE: FL 2014
 OCC CLASS: 5TH ED R-2
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-06-28 Cont ID  
Sent By shill Date 2017-06-28 Time 16:38 Rev Time 0.00
Received By shill Date 2017-06-28 Time 10:31 Sent To  
Notes
2017-06-28 12:56:46****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1-2. OK
  
 3. FROM PREVIOUS LISTS: KAYKAN SOFFIT PRODUCT APPROVAL,
 INDICATE WHICH PRODUCT AND INSTALLATION METHOD IS
 PROPOSED (DRAWING PAGE 1 OF 15).
  
 2ND REVIEW, THE DOCUMENT SUBMITTED IS NOT A PART OF THE
 PRODUCT APPROVAL. IT APPEARS TO BE AN EVALUATION REPORT
 BUT DOES NOT INCLUDE A PRODUCT APPROVAL NUMBER. ONE
 ITEM IS CIRCLED, 20' MRH, BUT THE APARTMENT BUILDINGS
 ARE FOUR STORIES.
  
 THIS ITEM CAN BE A PROVISO UPON REQUEST - PRIOR TO
 INSTALLATION, SUBMIT PRODUCT APPROVAL WITH INSTALLATION
 METHOD INDICATED.
  
 3RD REVIEW, RESPONSE LETTER STATES THAT IT IS ATTACHED,
 BUT I WAS UNABLE TO LOCATE THIS INFORMATION.
  
 4. OK
  
 5. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB, FBC 105.
  
 6. TEST REPORTS FOR THE FLOORING UNDERLAYMENT WERE NOT
 PROVIDED. "GROUNDWORKS" SPEC SHEET WAS PROVIDED.
  
 PROVIDE TEST REPORTS FOR THE FLOORING UNDERLAYMENT
 ACOUSTIC INSULATION:
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492.
  
 C. FBC B 720.2 OR 603.1, PROVIDE TEST DATA IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 (FLAME SPREAD).
  
 3RD REVIEW, RESPONSE LETTER REFERS TO AN EXCEPTION FOR
 COMBUSTIBLE INSULATION BOARDS NOT MORE THAN 1/2"; IT
 APPEARS THAT THE PROPOSED PRODUCT IS A ROLLED PRODUCT,
 NOT BOARDS. AFTER SHOWING COMPLIANCE WITH STC AND ICC,
 CONSIDERATION CAN BE GIVEN TO APPLYING THIS EXCEPTION
 TO THE FLAME SPREAD REQUIREMENT IF THE PRODUCT DOES NOT
 ALREADY HAVE A FLAME SPREAD TEST.
  
 STC AND IIC TEST REPORTS ARE REQUIRED. DUE TO THE
 INCONSISTENCIES IN MANUFACTURERS' SPEC SHEETS, PERMITS
 ARE NOT ISSUED BASED ON THE SPEC SHEETS. YOU MAY SEND
 THE TEST REPORTS VIA EMAIL FOR PRELIMINARY REVIEW.
 PRIOR TO SENDING THE TEST REPORTS, CONFIRM THAT THE
 ASSEMBLY TESTED DID NOT INCLUDE A DROPPED GYPSUM
 CEILING. AN ANALYSIS MAY BE REQUIRED FOR HOLLOW CORE AS
 I'VE NEVER SEEN A PRODUCT TESTED WITH A HOLLOW CORE
 FLOOR, ONLY CONCRETE SLABS.
  
 NEW COMMENT:
  
 7. A CODE SUMMARY WAS ADDED TO SHEET A2.4B; CLUBHOUSE
 OCCUPANCY CLASSIFICATION IS DECLARED AS B. THIS SHOULD
 BE MIXED OCCUPANCY; CLUBHOUSE IS ASSEMBLY OCCUPANCY
 (PROBABLY A3), REVISE.
  
 THE PLAN CAN BE REDLINED UPON REQUEST.
  
 PLAN HAVE BEEN STAMPED AS APPROVED. THE FLOORING
 UNDERLAYMENT ISSUE AND VALUE CAN BE RESOLVED VIA EMAIL.
 THE SOFFIT PRODUCT APPROVAL CAN BE PROVISO ITEM UPON
 REQUEST.
  
 *****************************************
 16111261 BLDG 1 (NORTH)
 16111265 BLDG 2
 16111259 CLUBHOUSE
  
 16111261 BUILDING DATA FOR C.O./REPORTING
 USC-404 TYPE 434 - ALT RESIDENTIAL
 SQUARE FEET - 69509
  
 CONSTRUCTION TYPE: 14-2-B
 UNITS:
 FLOORS: 4
 BEDROOMS:
 ROOMS:
 SQ FT LIVABLE: 69509
 SQ FT FOOTPRINT: 18480
 SQ FT ROOF: 18480
  
 SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF
 KNOWN):
 SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN):
 XX.XX
 SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN:
 XX.XX
 OCC LOAD:
 PROP USE: APARTMENT
 SPRINKLER SYS? Y
 SPRK REQ'D? Y
 BATHRMS:
  
 BLDG CODE: FL 2014
 OCC CLASS: 5TH ED R-2
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-03-28 Cont ID  
Sent By shill Date 2017-03-28 Time 15:56 Rev Time 0.00
Received By shill Date 2017-03-27 Time 16:19 Sent To  
Notes
2017-03-28 15:56:47****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1-2. OK
  
 3. FROM PREVIOUS LIST: KAYKAN SOFFIT PRODUCT APPROVAL,
 INDICATE WHICH PRODUCT AND INSTALLATION METHOD IS
 PROPOSED (DRAWING PAGE 1 OF 15).
  
 2ND REVIEW, THE DOCUMENT SUBMITTED IS NOT A PART OF THE
 PRODUCT APPROVAL. IT APPEARS TO BE AN EVALUATION REPORT
 BUT DOES NOT INCLUDE A PRODUCT APPROVAL NUMBER. ONE
 ITEM IS CIRCLED, 20' MRH, BUT THE APARTMENT BUILDINGS
 ARE FOUR STORIES.
  
 THIS ITEM CAN BE A PROVISO UPON REQUEST - PRIOR TO
 INSTALLATION, SUBMIT PRODUCT APPROVAL WITH INSTALLATION
 METHOD INDICATED.
  
 4. OK
  
 5. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB, FBC 105.
  
 6. TEST REPORTS FOR THE FLOORING UNDERLAYMENT WERE NOT
 PROVIDED. "BRAVO UNDERLAYMENT" SPEC SHEET WAS PROVIDED.
  
 PROVIDE TEST REPORTS FOR THE FLOORING UNDERLAYMENT
 ACOUSTIC INSULATION:
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST,
 PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED
 THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE
 GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL
 NOT BE ALTERED.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART
 OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN
 DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW
 IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT
 BELOW WILL NOT BE ALTERED.
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 720.2 OR 603.1, PROVIDE TEST DATA IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 (FLAME SPREAD).
  
 7. BUILDING TYPE (SHEET G0.1) IS IIIB. REVISE PLAN TO
 INCLUDE THE FLOOR CEILING ASSEMBLY; THIS INFORMATION IS
 REQUIRED TO DETERMINE COMPLIANCE FOR THE FLOORING
 UNDERLAYMENT SELECTED.
  
 RESPONSE LETTER STATES THAT THIS IS HOLLOW CORE PLANK,
 BUT THE PLAN WAS NOT REVISED. THIS CAN BE A PROVISO
 ITEM UPON REQUEST. RESPONSE LETTERS ARE HELPFUL FOR
 REVIEW BUT NOT SIGNED AND SEALED, ARE NOT RETAINED, ARE
 NOT A PART OF THE PERMIT RECORD.
  
 8-10. OK
  
 NEW COMMENT:
  
 11. FIRE RATED WINDOWS ARE SPECIFIED. THIS PERMIT WILL
 BE ISSUED WITH PROVISO, PRODUCT APPROVAL FOR THE WINDOW
 AND IMPACT PROTECTION TO BE SUBMITTED PRIOR TO
 INSTALLATION. INSTALLATION METHOD TO BE MARKED ON THE
 IMPACT PROTECTION PRODUCT APPROVAL. A SHUTTER
 INSTALLATION PLAN IS ALSO REQUIRED; WHO WILL DO THE
 INSTALLATION, WHERE THE IMPACT PROTECTION WILL BE
 STORED IF REMOVABLE IMPACT PROTECTION IS PROPOSED, HOW
 IT WILL BE INSTALLED ON A FOUR STORY BUILDING.
  
 WHEN A FIRE RATED WINDOW IS REQUIRED, RATED GLASS BLOCK
 IS OFTEN USED AS THERE IS NO IMPACT REQUIREMENT IN
 NON-HVHZ.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-12-12 Cont ID  
Sent By shill Date 2016-12-12 Time 14:51 Rev Time 0.00
Received By shill Date 2016-12-09 Time 12:21 Sent To  
Notes
2016-12-12 14:51:14****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. S0.1, EXPLAIN VELOCITY HEIGHT OF 20FT FOR RESIDENT
 BUILDINGS. IS THIS THE MEAN ROOF HEIGHT? THIS IS A FOUR
 STORY BUILDING. REVISE OR CLARIFY, FBC 107. IT IS NOT
 CLEAR WHY THE CLUBHOUSE PRESSURES, INCLUDING ROOF
 PRESSURES, ARE IN SOME CASES HIGHER THAN THE RESIDENT
 BUILDINGS (OR VERY CLOSE TO THE SAME), BUT THE
 CLUBHOUSE IS ONE STORY, PITCHED ROOF; RESIDENT
 BUILDINGS ARE FOUR STORIES, FLAT ROOF.
  
 2. SPECIFY SOFFIT PRESSURES, FBC 1609.
  
 3. KAYKAN SOFFIT PRODUCT APPROVAL, INDICATE WHICH
 PRODUCT AND INSTALLATION METHOD IS PROPOSED (DRAWING
 PAGE 1 OF 15).
  
 4. MULE HIDE SINGLE PLY ROOF PRODUCT APPROVAL WAS
 SUBMITTED. THE ASSEMBLY PROPOSED WAS NOT INDICATED.
  
 IF THIS INFORMATION IS NOT PROVIDED, THIS INFORMATION
 WILL BE REQUIRED AT TIME OF ROOF SUB PERMIT
 APPLICATION, FBC 1609.
  
 5. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THIS JOB, FBC 105.
  
 6. PROVIDE TEST REPORTS FOR THE FLOORING UNDERLAYMENT
 ACOUSTIC INSULATION:
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST,
 PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED
 THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE
 GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL
 NOT BE ALTERED.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART
 OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN
 DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW
 IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT
 BELOW WILL NOT BE ALTERED.
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 720.2 OR 603.1, PROVIDE TEST DATA IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 (FLAME SPREAD).
  
 7. BUILDING TYPE (SHEET G0.1) IS IIIB. REVISE PLAN TO
 INCLUDE THE FLOOR CEILING ASSEMBLY; THIS INFORMATION IS
 REQUIRED TO DETERMINE COMPLIANCE FOR THE FLOORING
 UNDERLAYMENT SELECTED.
  
 8. FBC A 604.5.2, THE REAR GRAB BAR IS TO EXTEND 12 IN
 ONE DIRECTION AND 24 INCHES IN THE OTHER DIRECTION
 (TRANSFER SIDE); SEE DETAIL 1 A 5.4, DETAIL DEPICTS THE
 GRAB BAR CENTERED. REVISE ALL AFFECTED DETAILS AND
 PLANS.
  
 9. FBC EC CHAPTER 2 DEFINITIONS, SEE DEFINITION OF
 RESIDENTIAL BUILDING (THREE STORIES OR LESS); PROVIDE
 COMMERCIAL BUILDING ENERGY CALCS, FBC EC C103.
  
 10. FBC EB, PROVIDE INFORMATION AS TO HOW IT WAS
 DETERMINED THAT THIS IS A LEVEL II ALTERATION (RATHER
 THAN A LEVEL III). PLEASE SEND THIS INFORMATION VIA
 EMAIL FOR PRELIMINARY REVIEW PRIOR TO RESUBMITTAL.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-03-27 Cont ID  
Sent By vperez Date 2017-03-27 Time 07:12 Rev Time 0.00
Received By vperez Date 2017-03-27 Time 07:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-01-04 Cont ID  
Sent By mvaldes Date 2017-01-04 Time 14:42 Rev Time 0.00
Received By mvaldes Date 2017-01-04 Time 10:18 Sent To  
Notes
2017-01-04 15:35:12JOB PERMIT NUMBER: 16111261
 JOB ADDRESS: 2100 NORTH AUSTRALIAN AVE
 WEST PALM BEACH FLORIDA
 DATE: JANUARY 4, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 - THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC
 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA
 BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH
 AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED.
  
 1] FIRE ALARM, LOW VOLTAGE, & SITE LIGHTING SHALL BE
 SUBMITTED UNDER A SEPARATE PERMIT WITH SEPARATE SHOP
 DRAWINGS.
  
 2] A MINIMUM OF 75% OF PERMANENTLY INSTALLED LUMINAIRES
 SHALL BE HIGH EFFICIENT & RECESSED LIGHTS INSTALLED IN
 BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR
 LEAKAGE BETWEEN CONDITIONED & UN-CONDITIONED SPACES,
 THE HOUSING CANS IF IN CONTACT WITH THERMAL INSULATION
 SHALL BE LISTED IC-RATED. FBC-ENERGY SECTIONS R402.4.4
 & R404.1 (ADD A NOTE ON SHEET E0.1)
  
 3] OPENINGS AROUND ELECTRICAL PENETRATIONS INTO OR
 THROUGH FIRE RESISTANT WALLS, PARTITIONS, FLOORS, &
 CEILINGS SHALL BE FIRE STOPPED USING APPROVED METHODS
 TO MAINTAIN THE FIRE RATING. NEC 300.21 THIS APPLIES TO
 HALLWAY CORRIDORS IN SHEETS E1.1, E1.2, E1.3. (ADD A
 NOTE)
  
 4] DEPENDING ON CONDUIT ROUTING PLEASE REFERENCE NEC
 310.15 FOR TEMPERATURE ADJUSTMENT & CORRECTIONS FOR
 CONDUCTORS BEING RAN ON THE ROOFTOP EXPOSED TO DIRECT
 SUNLIGHT. ADD A NOTE ON SHEET E1.4.
  
 5] PROVIDE AFCI PROTECTION TO NEW OR MODIFIED CIRCUITS
 IN ACCORDANCE WITH NEC 210.12(A)(B). ADD A NOTE ON
 SHEET E2.1, E2.2, E2.3.
  
 6] PROVIDE ILLUMINATION FOR THE PANELBOARD ON BEDROOM 1
 PER NEC 110.26(D).
  
 7] CLARIFY IF DISTRIBUTION PANELS ARE ACCESSIBLE TO
 TENANT'S OR IS THEIR MAINTENANCE PERSONNEL WITH KEY
 LOCK ACCESS IN ACCORDANCE WITH NEC 240.24(B).
  
 8] PROVIDE EMERGENCY LIGHTING IN MEN'S/WOMAN'S BATHROOM
 & MECHANICAL ROOM FOR MEANS OF EGRESS ILLUMINATION PER
 FBC 1006.
  
 9] SHOW IDENTIFICATION ON THE RISER DIAGRAM OF UNIT #'S
 ON THE MAIN DISCONNECTS & THE DISTRIBUTION PANELS SHALL
 HAVE THE SOURCE OF SUPPLY MARKING PER NEC 225.37,
 408.4(B).
  
 - PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER
 RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES
 WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER
 QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME
 DIRECTLY.
  
 1ST REVIEW FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-05-31 Cont ID  
Sent By pleduc Date 2017-05-31 Time   Rev Time 0.00
Received By pleduc Date 2017-05-31 Time 10:24 Sent To  
Notes
2017-05-31 10:47:15THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY
 CERTIFIED LIFE SAFETY CONTRACTORS.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-03-29 Cont ID  
Sent By pleduc Date 2017-03-29 Time   Rev Time 0.00
Received By pleduc Date 2017-03-29 Time 14:01 Sent To  
Notes
2017-03-29 14:48:44THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY
 CERTIFIED LIFE SAFETY CONTRACTORS.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-12-16 Cont ID  
Sent By pleduc Date 2016-12-16 Time   Rev Time 0.00
Received By pleduc Date 2016-12-14 Time 09:39 Sent To  
Notes
2016-12-14 16:02:51THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1)SHEET A1.1A - CANOPY'S ARE NOTED ON THE EXTERIOR OF
 THE STAIRWELL EXITS. THOSE CANOPYS ARE TO BE FIRE
 RETARDENT MATERIAL AND UNDER SEPARATE PERMIT WITH THE
 CANOPY STRUCTURE WITH SUPPORTING DOCUMENTATION.
  
 PLEASE PROVIDE A NOTE INDICATING ACKNOWLEDGEMENT WITH
 THE ABOVE.
  
  
 2) SHEET A2.0 - UNDER THE "C" DRAWING A HORIZONTAL
 SLIDER WINDOW IS INDICATED WITH THE STAIRWELL WALL. THE
 WALL IS REQUIRED TO HAVE A RATING. ANY OPENING IN THE
 RATING WALL SHALL CONTAIN THE SAME RATING REQUIRMENT.
  
 7.2.2.5 ENCLOSURE AND PROTECTION OF STAIRS.
 7.2.2.5.1 ENCLOSURES.
 7.2.2.5.1.1 ALL INSIDE STAIRS SERVING AS AN EXIT OR
 EXIT COMPONENT SHALL BE ENCLOSED IN ACCORDANCE WITH
 7.1.3.2.
  
 7.1.3.2 EXITS.
 7.1.3.2.1 WHERE THIS CODE REQUIRES AN EXIT TO BE
 SEPARATED FROM OTHER PARTS OF THE BUILDING, THE
 SEPARATING CONSTRUCTION SHALL MEET THE REQUIREMENTS OF
 SECTION 8.2 AND THE FOLLOWING:
 (1)* THE SEPARATION SHALL HAVE A MINIMUM 1-HOUR FIRE
 RESISTANCE RATING WHERE THE EXIT CONNECTS THREE OR
 FEWER STORIES.
 (2) THE SEPARATION SPECIFIED IN 7.1.3.2.1(1), OTHER
 THAN AN EXISTING SEPARATION, SHALL BE SUPPORTED BY
 CONSTRUCTION HAVING NOT LESS THAN A 1-HOUR FIRE
 RESISTANCE RATING.
 (3)* THE SEPARATION SHALL HAVE A MINIMUM 2-HOUR FIRE
 RESISTANCE RATING WHERE THE EXIT CONNECTS FOUR OR MORE
 STORIES, UNLESS ONE OF THE FOLLOWING CONDITIONS EXISTS:
 (A) IN EXISTING NON-HIGH-RISE BUILDINGS, EXISTING EXIT
 STAIR ENCLOSURES SHALL HAVE A MINIMUM 1-HOUR FIRE
 RESISTANCE RATING.
 (B) IN EXISTING BUILDINGS PROTECTED THROUGHOUT BY AN
 APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN
 ACCORDANCE WITH SECTION 9.7, EXISTING EXIT STAIR
 ENCLOSURES SHALL HAVE A MINIMUM 1-HOUR FIRE RESISTANCE
 RATING.
 (C) THE MINIMUM 1-HOUR ENCLOSURES IN ACCORDANCE WITH
 28.2.2.1.2, 29.2.2.1.2, 30.2.2.1.2, AND 31.2.2.1.2
 SHALL BE PERMITTED AS AN ALTERNATIVE TO THE REQUIREMENT
 OF 7.1.3.2.1(3).
  
 PLEASE PROVIDE THE RATING OF THE SLIDER WINDOW.
  
  
 3) SHEET G0.1 - THERE IS NO INDICATIONS OF ANY EXISTING
 FIRE SPRINKLER SYSTEM AND/OR THAT ANY SPRINKLER WORK
 SHALL BE DONE UNDER SEPARATE SHOP DRAWING BY A
 QUALIFIED LIFE SAFETY CONTRACTOR.
  
 2014 FL BLDG CODE
  
 105.3.1.2
 NO PERMIT MAY BE ISSUED FOR ANY BUILDING CONSTRUCTION,
 ERECTION, ALTERATION, MODIFICATION, REPAIR, OR ADDITION
 UNLESS THE APPLICANT FOR SUCH PERMIT PROVIDES TO THE
 ENFORCING AGENCY WHICH ISSUES THE PERMIT ANY OF THE
 FOLLOWING DOCUMENTS WHICH APPLY TO THE CONSTRUCTION FOR
 WHICH THE PERMIT IS TO BE ISSUED AND WHICH SHALL BE
 PREPARED BY OR UNDER THE DIRECTION OF AN ENGINEER
 REGISTERED UNDER CHAPTER 471, FLORIDA STATUTES:
  
 2. FIRE SPRINKLER DOCUMENTS FOR ANY NEW BUILDING OR
 ADDITION WHICH INCLUDES A FIRE SPRINKLER SYSTEM WHICH
 CONTAINS 50 OR MORE SPRINKLER HEADS. PERSONNEL AS
 AUTHORIZED BY CHAPTER 633 FLORIDA STATUTES, MAY DESIGN
 A FIRE SPRINKLER SYSTEM OF 49 OR FEWER HEADS AND MAY
 DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER
 SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION,
 ADDITION OR DELETION OF NOT MORE THAN 49 HEADS,
 NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER
 SYSTEM.
  
 PLEASE PROVIDE THE APPLICABLE INFORMATION/DOCUMENTATION
 INDICATING COMPLAINCE WITH THE ABOVE NOTED INFORMATION.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-10-02 Cont ID  
Sent By tklarge Date 2017-10-02 Time 14:10 Rev Time 0.00
Received By tklarge Date 2017-09-26 Time 15:52 Sent To  
Notes
2017-09-27 15:52:28RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2017-08-30 Time   Rev Time 0.00
Received By lmarchan Date 2017-08-01 Time 09:59 Sent To  
Notes
2017-08-02 09:59:42C36

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-06-28 Cont ID  
Sent By shill Date 2017-06-28 Time 12:56 Rev Time 0.00
Received By shill Date 2017-05-25 Time 12:03 Sent To  
Notes
2017-05-26 12:07:15C37

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-15 Cont ID  
Sent By skennedy Date 2017-05-15 Time 09:41 Rev Time 0.00
Received By skennedy Date 2017-03-23 Time 13:56 Sent To  
Notes
2017-03-24 14:05:12C33
 *TRAVELLING TOGETHER 16111259, 16111261, 16111265*

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-01-04 Cont ID  
Sent By mvaldes Date 2017-01-04 Time 15:46 Rev Time 0.00
Received By mvaldes Date 2016-11-30 Time 10:28 Sent To  
Notes
2016-12-02 10:28:27C29
 **TRAVELLING WITH 16111259 & 16111265**

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-12-12 Cont ID  
Sent By shill Date 2016-12-12 Time 14:24 Rev Time 0.00
Received By shill Date 2016-12-12 Time 14:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2017-08-30 Cont ID  
Sent By ccole Date 2017-08-30 Time 12:29 Rev Time 0.00
Received By ccole Date 2017-08-30 Time 12:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-06-08 Cont ID  
Sent By ccole Date 2017-06-08 Time 16:52 Rev Time 0.00
Received By ccole Date 2017-06-08 Time 17:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-03-29 Cont ID  
Sent By ccole Date 2017-03-29 Time 10:10 Rev Time 0.00
Received By ccole Date 2017-03-29 Time 10:09 Sent To  
Notes
2017-03-29 10:10:282ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16111261
 3/29/17
  
 1) ENERGY COMPLIANCE: DUPLICATE COPIES OF THE SUBMITTED
 ENERGY COMPLIANCE FORM C402-2014 ARE REQUIRED FOR BOTH
 BUILDINGS #1 & 2. ONLY TWO FORMS WERE SUBMITTED AND NO
 BUILDING NUMBERS ARE SHOWN ON THE FORMS.
  
 2) SHEET M2.2: THERE IS A RETURN TRANSFER MISSING IN
 THE MIDDLE BEDROOM OF THE 2-BEDROOM UFAS UNIT.
  
 3) SHEET M3.2: INDICATE THE NUMBER OF CLIPS TO BE
 INSTALLED ON THE CONDENSER UNITS. PROVIDE TWO COPIES OF
 FL. PRODUCT APPROVAL #19731 WITH A SHOP DRAWING
 APPROVAL STAMP BY THE ARCHITECT OF RECORD. THE
 ARCHITECT MUST ALSO CIRCLE, HIGHLIGHT, OR OTHERWISE
 MARK ALL APPLICABLE ANCHORING DETAILS, NOTES, DESIGN
 PRESSURES ETC. ON THE PRODUCT APPROVAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-12-07 Cont ID  
Sent By ccole Date 2016-12-07 Time 10:46 Rev Time 0.00
Received By ccole Date 2016-12-07 Time 10:46 Sent To  
Notes
2016-12-07 11:15:081ST REVIEW FBC-2014 MECHANICAL
 PERMIT #16111261
 12/7/16
  
 1) THE RESIDENTIAL ENERGY COMPLIANCE FORM R405-2015
 CANNOT BE USED ON A COMMERCIAL BUILDING. PLEASE SEE
 DEFINITIONS OF RESIDIENTIAL AND COMMERCIAL IN SECTIONS
 C202 & R202 FBC-14 ENERGY CONSERVATION. RESIDENTIAL
 CLASSIDICATION IS LIMITED TO THREE STORIES. THE
 BUILDING BEING RENOVATED IS FOUR STORIES.
  
 2) SUBMIT AC CHANGEOUT FORMS FOR THE REPLACED SYSTEMS.
 THE FORMS CAN BE FOUND ON THE DEVELOPMENT SERVICES
 WEBSITE- WWW.CITYOFWPB.COM.
  
 3) SHEET M2.3: THE 8X6 TRANSFER DUCTS IN THE
 THREE-BEDROOM UNITS ARE UNDERSIZED PER SECTION
 601.5.(1).
  
 4) PROVIDE SITE SPECIFIC WIND LOAD ENGINEERING FOR
 ANCHORING THE NEW CONDENSER UNITS TO THE EXISTING ROOF
 STANDS- SECTION 301.15.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2017-10-02 Cont ID  
Sent By tklarge Date 2017-10-02 Time 14:10 Rev Time 0.00
Received By tklarge Date 2017-10-02 Time 14:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2017-08-25 Cont ID  
Sent By tklarge Date 2017-08-25 Time 14:49 Rev Time 0.00
Received By tklarge Date 2017-08-25 Time 13:48 Sent To  
Notes
2017-08-25 13:54:411) SHT. P1.1 - PLUMBING NOTES - THERE IS A NOTE STATING
 THAT PVC IN THE PLENUM CLOSET IS TO BE WRAPPED WITH
 PLENUM RATED ARMAFLEX. PVC IS NOT RATED FOR USE WITHIN
 A PLENUM. THE ARMAFLEX MAY BE APPROVED FOR USE IN A
 PLENUM BUT THE PVC WITHIN THE PLENUM IS STILL A
 VIOLATION. THE ARMAFLEX DOES NOT PROTECT THE PVC FROM
 IGNITION AND DOES NOT MEET THE INTENT OF THE CODE.
 COMPLY WITH 2014 FBC - MECHANICAL SEC.602.2.
 2) REMOVE SHEETS P3.8 & P3.9 AS NOTED IN NARRATIVE FROM
 DESIGN PROFESSIONAL.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2017-06-28 Cont ID  
Sent By tklarge Date 2017-06-28 Time 06:35 Rev Time 0.00
Received By tklarge Date 2017-06-28 Time 05:12 Sent To  
Notes
2017-06-28 05:13:021) SHOW THE DIMENSIONS (LXW) OF THE REQUIRED CLEAR
 FLOOR SPACE FOR THE WATER CLOSETS, LAVATORIES, KITCHEN
 SINKS & SHOWERS IN THE UFAS UNITS. THE REQUIRED CLEAR
 FLOOR SPACE FOR THE FIXTURES SHALL COMPLY WITH UFAS
 SECS.4.34.5.2 THROUGH 4.34.6.5.
 2) SUBMIT DETAILS FOR THE REQUIRED REINFORCEMENT FOR
 GRAB BARS FOR THE WATER CLOSETS & SHOWERS. COMPLY WITH
 UFAS SECS. 4.34.5.2 (3), 4.34.5.5 (3) & FIGURES 47 (B)
 & FIG. 49. SHOW THE MINIMUM AND MAXIMUM MEASUREMENTS
 FROM THE FLOOR AND THE MINIMUM LENGTHS AND DIMENSIONS
 OF THE REINFORCING ON SHTS. A5.2, A5.3 & A5.4.
 3) SUBMIT AN ELEVATION DETAIL OF THE HILO DRINKING
 FOUNTAIN.COMPLY WITH UFAS SECS. 4.1.6, 4.4.1.2, 4.15.
 4) SHT.A5.4 - DETAIL #1 - SHOW THE DIMENSIONS OF THE
 CLEAR FLOOR SPACES REQUIRED FOR THE ACCESSIBLE
 LAVATORIES AND WATER CLOSETS.
 5) SHT. A5.4 - DETAILS A,B,C & D SHOWS A GRAB BAR IN
 THE TOILET ROOM ACCESSIBLE STALL MOUNTED IN THE
 VERTICAL POSITION BUT UFAS SEC.4.17.6 AND FIG. (A) SHOW
 THE GRAB BARS ONLY IN A HORIZONTAL POSITION. GRAB BARS
 INSTALLED IN A VERRTICAL POSITION DO NOT APPEAR TO
 COMPLY WITH UFAS. CLARIFY.
 6) SHT. A5.4 - ELEVATION DETAILS "A" & "B" DO NOT
 APPEAR TO CORRELATE WITH THE PLAN VIEW ON DETAIL #1 -
 CLARIFY.
 7) A6.4 - DETAIL #1 - THE HEIGHT OF THE SINK IN THE
 CLUBHOUSE ACTIVITY ROOM SHALL BE A MAXIMUM OF 34 INCHES
 ABOVE THE FINISH FLOOR. UFAS SEC. 4.24.2.
 8) SHT. P1.1 - PLUMBING NOTES - THERE IS A NOTE STATING
 THAT PVC IN THE PLENUM CLOSET IS TO BE WRAPPED WITH
 PLENUM RATED ARMAFLEX. PVC IS NOT RATED FOR USE WITHIN
 A PLENUM. SUBMIT TWO COPIES OF MANUFACTURER'S
 SPECIFICATIONS FOR THE PLENUM RATED ARMAFLEX AND
 DETAILS AS TO HOW THE ARMAFLEX WILL BE INSTALLED ON THE
 PVC PIPE.WPB AMEND. TO FBC SEC. 107.2.1.
 9) SHT. P1.1 - WATER HEATER DETAIL - HEAT TRAPS ARE
 REQUIRED ON THE HOT AND COLD WATER LINES OF THE WATER
 HEATER. 2014 FBC-ENERGY SEC.C404.4,
 10) SHT. P2.2 - SHUTOFF VALVES ARE REQD. AT THE BASE OF
 THE WATER RISERS. 2014 FBC-PLUMBIING SEC.606.1 (4).
 11) SHTS. P3.1, P3.2, P3.3, & P3.5 - THE HUB DRAIN
 SHALL CONNECT TO THE SANITARY SYSTEM DOWNSTREAM OF THE
 WATER CLOSET.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-04-25 Cont ID  
Sent By gjohnson Date 2017-04-25 Time 16:46 Rev Time 0.00
Received By gjohnson Date 2017-04-25 Time 16:46 Sent To  
Notes
2017-04-25 16:45:062ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHT. P3.4 THE HUB DRAIN SHALL CONNECT TO THE WET
 VENT DOWN STREAM OF BRANCH DRAIN OF WATER CLOSET. FBC
 PL 912.1
  
 2. SHT. P3.2 THE HUB DRAIN SHALL CONNECT TO THE WET
 VENT DOWN STREAM OF BRANCH DRAIN OF THE LAVATORY. FBC
 PL 912.1
  
 3.SHT. P3.8 THE NOTE UNDER THE TAG FOR RISER S-8 REFERS
 TO SHT. P3.7 S-8 RISER IS NOT SHOWN ON P3.7 PLEASE
 PROVIDE.
  
 4. SHT P3.8 WATER CLOSET IN HALF BATH IS NOT VENTED IT
 SHALL BE VENTED BEFORE IT CONNECTS TO THE BUILDING
 DRAIN. PER FBC PL901.2.1
  
 5. SHT. P3.7 + P3-9 APEAR TO BE THE SAME PLEAS CLARIFY.
 PER WPB AMEND TO FBC 107.2.1
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-12-22 Cont ID  
Sent By gjohnson Date 2016-12-22 Time 11:25 Rev Time 0.00
Received By gjohnson Date 2016-12-22 Time 11:25 Sent To  
Notes
2016-12-22 13:00:461ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. SHOW WHEELCHAIR TURNING SPACE IN ACCESSIBLE
 BATHROOMS. PER UFAS 4.2.3 AND 4.23.3
  
 2. PROVIDE DIMENSIONS FOR THE SHOWER CONTROLS OFF THE
 FRONT OF THE SHOWER STALL. PER UFAS 4.34.5.5(4)
  
 3. SHOW TRAP PRIMERS FOR HUB DRAINS ON RISER DIAGRAMS.
 PER WPB AMEND TO FBC 107.2.1
  
 4. SHT. P3.2 AND P3.4 RISER DETAIL W1 AND W2 ARE NAMED
 AS SANITARY RISER PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2.1
  
 5. SHT. P3.2 AND P3.4 RISER DETAIL W1 AND W2 ARE THESE
 EXISTING TO REMAIN OR ARE THEY NEW PLEASE CLARIFY. PER
 WPB AMEND TO FBC 107.2.1
  
 6. SHT. P3.7 RISER S7 AND P3.8 WC1 IN POWDER ROOM
 SHOULD BE VENTED BY LAV STACK IN POWDER ROOM. FBC PL
 901.2.1
  
 7. SHT P3.8 WATER RISER W3 IS IT EXISTING TO REMAIN OR
 ARE THEY NEW PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2.1
  
 8. SHT. P3.8 S7 THE WATER CLOSETS ON THE FIRST FLOOR
 ARE NOT VENTED SHALL COMPLY WITH FBC PL 901.2.1
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-03-28 Cont ID  
Sent By shill Date 2017-03-28 Time 12:15 Rev Time 0.00
Received By shill Date 2017-03-28 Time 12:15 Sent To  
Notes
2017-03-28 12:16:58FL 12772-R3, MULE HIDE, ASSEMBLY C-1 (P.12)
  

Review Stop Z ZONING
Rev No 4 Status P Date 2017-06-08 Cont ID  
Sent By llouie Date 2017-06-08 Time   Rev Time 0.00
Received By llouie Date 2017-06-08 Time   Sent To  
Notes
2017-06-08 08:38:50- INTERIOR/EXTERIOR RENOVATIONS ONLY TO BUILDING #1, #2
 AND CLUBHOUSE.
  
 - DOES NOT INCLUDE SITE MODIFICATIONS (I.E. MONUMENT
 SIGN, FENCE, TOT LOT AND PARKING AREA STRIPING).
  
 CONTACT LINDA LOUIE @ 561-822-1458 IF THERE ARE
 QUESTIONS.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2017-04-03 Cont ID  
Sent By llouie Date 2017-04-03 Time   Rev Time 0.00
Received By llouie Date 2017-04-03 Time   Sent To  
Notes
2017-04-03 13:06:35- INTERIOR/EXTERIOR RENOVATIONS ONLY TO BUILDING #1, #2
 AND CLUBHOUSE.
  
 - DOES NOT INCLUDE SITE MODIFICATIONS (I.E. MONUMENT
 SIGN, FENCE, TOT LOT AND PARKING AREA STRIPING).
  
 CONTACT LINDA LOUIE @ 561-822-1458 IF THERE ARE
 QUESTIONS.

Review Stop Z ZONING
Rev No 2 Status F Date 2016-12-21 Cont ID  
Sent By llouie Date 2016-12-21 Time 11:32 Rev Time 0.00
Received By llouie Date 2016-12-21 Time 11:32 Sent To  
Notes
2016-12-21 11:38:13** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PROVIDE AN UPDATED SURVEY OF THE PROPERTY. THE
 SURVEY MUST BE LESS THAN 1 YEAR OLD.
  
 2.) THE SCOPE OF WORK DESCRIBED IN THE PERMIT
 APPLICATION INDICATES THAT ONLY INTERIOR WORK TO THE
 EXISTING RESIDENTIAL BUILDINGS AND THE CLUBHOUSE WILL
 BE DONE; HOWEVER, THE SITE PLAN (SHEET SP 1.1) ALSO
 SHOWS THAT EXTERIOR MODIFICATIONS PROPOSED FOR THE
 EXISTING RESIDENTIAL COMPLEX. SEPARATE PERMIT
 APPLICATIONS AND REVIEWS WILL BE REQUIRED FOR THE
 PROPOSED WORK (I.E. FREESTANDING SIGNAGE, NEW SHUFFLE
 BOARD COURT, NEW PLAYGROUND, PERIMETER FENCING,
 ENTRANCE GATES, ETC.).
  
 3.) THERE SEEMS TO BE A PROPOSED "CAR CARE AREA." THE
 CAR CARE AREA CANNOT BE PROVIDED UNLESS ADEQUATE
 PARKING IS PROVIDED FOR THE RESIDENTIAL DEVELOPMENT.
 PLEASE PROVIDE ADDITIONAL INFORMATION ON THE NUMBER OF
 EXISTING PARKING SPACES AND IF THE EXISTING PARKING
 MEETS CURRENT ZONING AND LAND DEVELOPMENT REGULATIONS
 REQUIREMENT FOR THE USE. THIS INFORMATION SHOULD BE
 DETAILED IN TABLE FORM IN THE SITE PLAN.
  
 4.) PROVIDE DETAILS FOR THE PROPOSED FENCE AND GATE
 SYSTEM.
  
 REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458
 IF THERE ARE QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-12-06 Cont ID  
Sent By ajones Date 2016-12-06 Time 14:27 Rev Time 0.00
Received By ajones Date 2016-12-06 Time 14:27 Sent To  
Notes
***NONE***