| Plan Review Stops For Permit 16111259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-04 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-04 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2017-08-04 17:37:12 | SEE PROVISOS UNDER PERMIT APPLICATION #16111261 | | | | | | ********************************** | | | BUILDING SUMMARY | | | | | | 16111261 BLDG 1 (NORTH) | | | 16111265 BLDG 2 (SOUTH) | | | 16111259 CLUBHOUSE | | | | | | SEE REVIEWS UNDER PERMIT APPLICATION #16111261 | | | | | | ************************** | | | BUILDING SUMMARY | | | | | | 16111261 BLDG 1 (NORTH) | | | 16111265 BLDG 2 (SOUTH) | | | 16111259 CLUBHOUSE | | | | | | 16111259 BUILDING DATA FOR C.O./REPORTING | | | USC-404 TYPE 434 - ALT RESIDENTIAL | | | SQUARE FEET - 2801 | | | | | | CONSTRUCTION TYPE: 14-3-B | | | UNITS: 1 | | | FLOORS: 1 | | | BEDROOMS: | | | ROOMS: | | | SQ FT LIVABLE: 2801 | | | SQ FT FOOTPRINT: 2801 | | | SQ FT ROOF: 2801 | | | | | | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF | | | KNOWN): | | | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): | | | XX.XX | | | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: | | | XX.XX | | | OCC LOAD: | | | PROP USE: CLUBHOUSE | | | SPRINKLER SYS? | | | SPRK REQ'D? | | | BATHRMS: | | | | | | BLDG CODE: FL 2014 | | | OCC CLASS: 5TH ED B (AND A3) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-28 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-28 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2017-06-28 15:04:18 | SEE REVIEWS UNDER PERMIT APPLICATION #16111261 | | | | | | ************************** | | | BUILDING SUMMARY | | | | | | 16111261 BLDG 1 (NORTH) | | | 16111265 BLDG 2 (SOUTH) | | | 16111259 CLUBHOUSE | | | | | | 16111259 BUILDING DATA FOR C.O./REPORTING | | | USC-404 TYPE 434 - ALT RESIDENTIAL | | | SQUARE FEET - 2801 | | | | | | CONSTRUCTION TYPE: 14-3-B | | | UNITS: 1 | | | FLOORS: 1 | | | BEDROOMS: | | | ROOMS: | | | SQ FT LIVABLE: 2801 | | | SQ FT FOOTPRINT: 2801 | | | SQ FT ROOF: 2801 | | | | | | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF | | | KNOWN): | | | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): | | | XX.XX | | | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: | | | XX.XX | | | OCC LOAD: | | | PROP USE: CLUBHOUSE | | | SPRINKLER SYS? | | | SPRK REQ'D? | | | BATHRMS: | | | | | | BLDG CODE: FL 2014 | | | OCC CLASS: 5TH ED | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-03-28 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-03-27 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2017-03-28 16:32:39 | SEE REVIEWS UNDER PERMIT APPLICATION #16111261 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-07 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-09 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2016-12-09 16:24:31 | SEE REVIEWS UNDER PERMIT APPLICATION #16111261 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-03-27 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-27 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-27 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-31 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-31 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2017-01-31 10:01:21 | FAILED BY MARIO VALDES- | | 2017-01-31 09:59:58 | JOB PERMIT NUMBER: 16111261 | | | JOB ADDRESS: 2100 NORTH AUSTRALIAN AVE | | | WEST PALM BEACH FLORIDA | | | DATE: JANUARY 4, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | - THE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH NEC | | | 2011, (NATIONAL ELECTRICAL CODE) AND FBC 2014, (FLORIDA | | | BUILDING CODE) AS WELL AS THE CITY OF WEST PALM BEACH | | | AMENDMENTS. SEE BELOW A LIST OF ITEMS NOTED. | | | | | | 1] FIRE ALARM, LOW VOLTAGE, & SITE LIGHTING SHALL BE | | | SUBMITTED UNDER A SEPARATE PERMIT WITH SEPARATE SHOP | | | DRAWINGS. | | | | | | 2] A MINIMUM OF 75% OF PERMANENTLY INSTALLED LUMINAIRES | | | SHALL BE HIGH EFFICIENT & RECESSED LIGHTS INSTALLED IN | | | BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR | | | LEAKAGE BETWEEN CONDITIONED & UN-CONDITIONED SPACES, | | | THE HOUSING CANS IF IN CONTACT WITH THERMAL INSULATION | | | SHALL BE LISTED IC-RATED. FBC-ENERGY SECTIONS R402.4.4 | | | & R404.1 (ADD A NOTE ON SHEET E0.1) | | | | | | 3] OPENINGS AROUND ELECTRICAL PENETRATIONS INTO OR | | | THROUGH FIRE RESISTANT WALLS, PARTITIONS, FLOORS, & | | | CEILINGS SHALL BE FIRE STOPPED USING APPROVED METHODS | | | TO MAINTAIN THE FIRE RATING. NEC 300.21 THIS APPLIES TO | | | HALLWAY CORRIDORS IN SHEETS E1.1, E1.2, E1.3. (ADD A | | | NOTE) | | | | | | 4] DEPENDING ON CONDUIT ROUTING PLEASE REFERENCE NEC | | | 310.15 FOR TEMPERATURE ADJUSTMENT & CORRECTIONS FOR | | | CONDUCTORS BEING RAN ON THE ROOFTOP EXPOSED TO DIRECT | | | SUNLIGHT. ADD A NOTE ON SHEET E1.4. | | | | | | 5] PROVIDE AFCI PROTECTION TO NEW OR MODIFIED CIRCUITS | | | IN ACCORDANCE WITH NEC 210.12(A)(B). ADD A NOTE ON | | | SHEET E2.1, E2.2, E2.3. | | | | | | 6] PROVIDE ILLUMINATION FOR THE PANELBOARD ON BEDROOM 1 | | | PER NEC 110.26(D). | | | | | | 7] CLARIFY IF DISTRIBUTION PANELS ARE ACCESSIBLE TO | | | TENANT'S OR IS THEIR MAINTENANCE PERSONNEL WITH KEY | | | LOCK ACCESS IN ACCORDANCE WITH NEC 240.24(B). | | | | | | 8] PROVIDE EMERGENCY LIGHTING IN MEN'S/WOMAN'S BATHROOM | | | & MECHANICAL ROOM FOR MEANS OF EGRESS ILLUMINATION PER | | | FBC 1006. | | | | | | 9] SHOW IDENTIFICATION ON THE RISER DIAGRAM OF UNIT #'S | | | ON THE MAIN DISCONNECTS & THE DISTRIBUTION PANELS SHALL | | | HAVE THE SOURCE OF SUPPLY MARKING PER NEC 225.37, | | | 408.4(B). | | | | | | - PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED ITEMS. WHEN RESUBMITTING, FOR A QUICKER | | | RETURN ON YOUR RE-SUBMITTAL, PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM. CLOUDING THE CHANGES | | | WILL BE GREATLY APPRECIATED. IF YOU HAVE FURTHER | | | QUESTIONS, PLEASE DON'T HESITATE TO CONTACT ME | | | DIRECTLY. | | | | | | 1ST REVIEW FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-31 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2017-05-31 12:13:41 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-03-29 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2017-03-29 14:59:11 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-12-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-12-16 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2016-12-16 09:37:43 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) PLEASE REFER TO COMMENTS OF PERMIT # 16111261. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2017-10-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-10-02 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-09-26 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2017-09-27 15:51:21 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-01 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-28 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-25 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-23 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2017-03-24 14:05:26 | C33 | | | *TRAVELLING TOGETHER 16111259, 16111261, 16111265* |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-31 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-31 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2016-12-02 10:28:11 | C29 | | | **TRAVELLING WITH 16111261 & 16111265** |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-12 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-12 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-30 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-30 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-06-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-08 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-08 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-03-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-03-29 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-03-29 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2017-03-29 10:40:06 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16111259 | | | 3/29/17 | | | | | | 1) SHEET M3.2: INDICATE THE NUMBER OF CLIPS TO BE | | | INSTALLED ON THE CONDENSER UNITS. PROVIDE TWO COPIES OF | | | FL. PRODUCT APPROVAL #19731 WITH A SHOP DRAWING | | | APPROVAL STAMP BY THE ARCHITECT OF RECORD. THE | | | ARCHITECT MUST ALSO CIRCLE, HIGHLIGHT, OR OTHERWISE | | | MARK ALL APPLICABLE ANCHORING DETAILS, NOTES, DESIGN | | | PRESSURES ETC. ON THE PRODUCT APPROVAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | 2017-03-29 10:31:42 | | | | | | | | | 2017-03-29 10:09:12 | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-07 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-05 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2016-12-07 10:44:48 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16111259 | | | 12/7/16 | | | | | | 1) SHEET M1.1: PROVIDE THE EFFICIENCY RATING OF THE | | | 10-TON UNIT IN THE SCHEDULE. | | | | | | 2) SUBMIT AN AC CHANGEOUT FORMS FOR THE REPLACED | | | SYSTEM. THE FORM CAN BE FOUND ON THE DEVELOPMENT | | | SERVICES WEBSITE- WWW.CITYOFWPB.COM. | | | | | | 3) ENERGYGAUGE COMPLIANCE FORM: A) CORRECT THE SYSTEM | | | NUMBER TO SYSTEM 4 TO MATCH THE PLANS. B) COMPLETE THE | | | MANDATORY REQUIREMENTS CHECKLIST ON PAGE 7. | | | | | | 4) PROVIDE SITE SPECIFIC WIND LOAD ENGINEERING FOR | | | ANCHORING THE NEW CU. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2017-10-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-10-02 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-10-02 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-08-25 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-08-25 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2017-08-25 13:56:56 | 1) SHT. P1.1 - PLUMBING NOTES - THERE IS A NOTE STATING | | | THAT PVC IN THE PLENUM CLOSET IS TO BE WRAPPED WITH | | | PLENUM RATED ARMAFLEX. PVC IS NOT RATED FOR USE WITHIN | | | A PLENUM. THE ARMAFLEX MAY BE APPROVED FOR USE IN A | | | PLENUM BUT THE PVC WITHIN THE PLENUM IS STILL A | | | VIOLATION. THE ARMAFLEX DOES NOT PROTECT THE PVC FROM | | | IGNITION AND DOES NOT MEET THE INTENT OF THE CODE. | | | COMPLY WITH 2014 FBC - MECHANICAL SEC.602.2. | | | 2) REMOVE SHEETS P3.8 & P3.9 AS NOTED IN NARRATIVE FROM | | | DESIGN PROFESSIONAL. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-06-28 |
Time |
06:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-06-28 |
Time |
03:12 |
Sent To |
|
|
| Notes |
| 2017-06-28 04:29:32 | 1) SHOW THE DIMENSIONS (LXW) OF THE REQUIRED CLEAR | | | FLOOR SPACE FOR THE WATER CLOSETS, LAVATORIES, KITCHEN | | | SINKS & SHOWERS IN THE UFAS UNITS. THE REQUIRED CLEAR | | | FLOOR SPACE FOR THE FIXTURES SHALL COMPLY WITH UFAS | | | SECS.4.34.5.2 THROUGH 4.34.6.5. | | | 2) SUBMIT DETAILS FOR THE REQUIRED REINFORCEMENT FOR | | | GRAB BARS FOR THE WATER CLOSETS & SHOWERS. COMPLY WITH | | | UFAS SECS. 4.34.5.2 (3), 4.34.5.5 (3) & FIGURES 47 (B) | | | & FIG. 49. SHOW THE MINIMUM AND MAXIMUM MEASUREMENTS | | | FROM THE FLOOR AND THE MINIMUM LENGTHS AND DIMENSIONS | | | OF THE REINFORCING ON SHTS. A5.2, A5.3 & A5.4. | | | 3) SUBMIT AN ELEVATION DETAIL OF THE HILO DRINKING | | | FOUNTAIN.COMPLY WITH UFAS SECS. 4.1.6, 4.4.1.2, 4.15. | | | 4) SHT.A5.4 - DETAIL #1 - SHOW THE DIMENSIONS OF THE | | | CLEAR FLOOR SPACES REQUIRED FOR THE ACCESSIBLE | | | LAVATORIES AND WATER CLOSETS. | | | 5) SHT. A5.4 - DETAILS A,B,C & D SHOWS A GRAB BAR IN | | | THE TOILET ROOM ACCESSIBLE STALL MOUNTED IN THE | | | VERTICAL POSITION BUT UFAS SEC.4.17.6 AND FIG. (A) SHOW | | | THE GRAB BARS ONLY IN A HORIZONTAL POSITION. GRAB BARS | | | INSTALLED IN A VERRTICAL POSITION DO NOT APPEAR TO | | | COMPLY WITH UFAS. CLARIFY. | | | 6) SHT. A5.4 - ELEVATION DETAILS "A" & "B" DO NOT | | | APPEAR TO CORRELATE WITH THE PLAN VIEW ON DETAIL #1 - | | | CLARIFY. | | | 7) A6.4 - DETAIL #1 - THE HEIGHT OF THE SINK IN THE | | | CLUBHOUSE ACTIVITY ROOM SHALL BE A MAXIMUM OF 34 INCHES | | | ABOVE THE FINISH FLOOR. UFAS SEC. 4.24.2. | | | 8) SHT. P1.1 - PLUMBING NOTES - THERE IS A NOTE STATING | | | THAT PVC IN THE PLENUM CLOSET IS TO BE WRAPPED WITH | | | PLENUM RATED ARMAFLEX. PVC IS NOT RATED FOR USE WITHIN | | | A PLENUM. SUBMIT TWO COPIES OF MANUFACTURER'S | | | SPECIFICATIONS FOR THE PLENUM RATED ARMAFLEX AND | | | DETAILS AS TO HOW THE ARMAFLEX WILL BE INSTALLED ON THE | | | PVC PIPE.WPB AMEND. TO FBC SEC. 107.2.1. | | | 9) SHT. P1.1 - WATER HEATER DETAIL - HEAT TRAPS ARE | | | REQUIRED ON THE HOT AND COLD WATER LINES OF THE WATER | | | HEATER. 2014 FBC-ENERGY SEC.C404.4, | | | 10) SHT. P2.2 - SHUTOFF VALVES ARE REQD. AT THE BASE OF | | | THE WATER RISERS. 2014 FBC-PLUMBIING SEC.606.1 (4). | | | 11) SHTS. P3.1, P3.2, P3.3, & P3.5 - THE HUB DRAIN | | | SHALL CONNECT TO THE SANITARY SYSTEM DOWNSTREAM OF THE | | | WATER CLOSET. | | | 12) SHT. P3.8 THE NOTE UNDER THE TAG FOR RISER S-8 | | | REFERS TO SHT. P3.7 S-8 RISER IS NOT SHOWN ON P3.7. | | | PLEASE PROVIDE. | | | 13) SHT P3.8 WATER CLOSET IN HALF BATH IS NOT VENTED IT | | | SHALL BE VENTED BEFORE IT CONNECTS TO THE BUILDING | | | DRAIN. PER FBC-PLBG. SEC.901.2.1 | | | 14) SHT. P3.7 + P3.9 APEAR TO BE THE SAME PLAN.PLEAS | | | CLARIFY. WPB AMEND TO FBC 107.2.1. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-25 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2017-04-25 16:38:48 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P3.4 THE HUB DRAIN SHALL CONNECT TO THE WET | | | VENT DOWN STREAM OF BRANCH DRAIN OF WATER CLOSET. FBC | | | PL 912.1 | | | | | | 2. SHT. P3.2 THE HUB DRAIN SHALL CONNECT TO THE WET | | | VENT DOWN STREAM OF BRANCH DRAIN OF THE LAVATORY. FBC | | | PL 912.1 | | | | | | 3.SHT. P3.8 THE NOTE UNDER THE TAG FOR RISER S-8 REFERS | | | TO SHT. P3.7 S-8 RISER IS NOT SHOWN ON P3.7 PLEASE | | | PROVIDE. | | | | | | 4. SHT P3.8 WATER CLOSET IN HALF BATH IS NOT VENTED IT | | | SHALL BE VENTED BEFORE IT CONNECTS TO THE BUILDING | | | DRAIN. PER FBC PL901.2.1 | | | | | | 5. SHT. P3.7 + P3-9 APEAR TO BE THE SAME PLEAS CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-12-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-22 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-22 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2016-12-22 13:22:18 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW WHEELCHAIR TURNING SPACE IN ACCESSIBLE | | | BATHROOMS. PER UFAS 4.2.3 AND 4.23.3 | | | | | | 2. PROVIDE DIMENSIONS FOR THE SHOWER CONTROLS OFF THE | | | FRONT OF THE SHOWER STALL. PER UFAS 4.34.5.5(4) | | | | | | 3. SHOW TRAP PRIMERS FOR HUB DRAINS ON RISER DIAGRAMS. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. SHT. P3.2 AND P3.4 RISER DETAIL W1 AND W2 ARE NAMED | | | AS SANITARY RISER PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. SHT. P3.2 AND P3.4 RISER DETAIL W1 AND W2 ARE THESE | | | EXISTING TO REMAIN OR ARE THEY NEW PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 6. SHT. P3.7 RISER S7 AND P3.8 WC1 IN POWDER ROOM | | | SHOULD BE VENTED BY LAV STACK IN POWDER ROOM. FBC PL | | | 901.2.1 | | | | | | 7. SHT P3.8 WATER RISER W3 IS IT EXISTING TO REMAIN OR | | | ARE THEY NEW PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 8. SHT. P3.8 S7 THE WATER CLOSETS ON THE FIRST FLOOR | | | ARE NOT VENTED SHALL COMPLY WITH FBC PL 901.2.1 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2016-12-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-12-12 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-12-12 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2016-12-12 08:56:47 | GAF SHINGLES PRODUCT APPROVAL 10124 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-06-08 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-06-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-06-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-08 08:39:58 | - INTERIOR/EXTERIOR RENOVATIONS ONLY TO BUILDING #1, #2 | | | AND CLUBHOUSE. | | | | | | - DOES NOT INCLUDE SITE MODIFICATIONS (I.E. MONUMENT | | | SIGN, FENCE, TOT LOT AND PARKING AREA STRIPING). | | | | | | CONTACT LINDA LOUIE @ 561-822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-04-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-04-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-04-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-04-03 13:02:48 | - INTERIOR/EXTERIOR BUILDING RENOVATIONS ONLY (BUILDING | | | #1, #2 AND CLUBHOUSE). | | | | | | - DOES NOT INCLLUDE SITE MODIFICATIONS (I.E. MONUMENT | | | SIGN, FENCE, TOT LOT AND PARKING AREA STRIPING). | | | SEPARATE PERMITS REQUIRED. | | | | | | - CONTACT LINDA LOUIE @ 561-822-1458 IF THERE AREA | | | QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-01-19 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-01-19 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2017-01-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-19 17:01:31 | | | | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PROVIDE AN UPDATED SURVEY OF THE PROPERTY. THE | | | SURVEY MUST BE LESS THAN 1 YEAR OLD. | | | | | | 2.) THE SCOPE OF WORK DESCRIBED IN THE PERMIT | | | APPLICATION INDICATES THAT ONLY INTERIOR WORK TO THE | | | EXISTING RESIDENTIAL BUILDINGS AND THE CLUBHOUSE WILL | | | BE DONE; HOWEVER, THE SITE PLAN (SHEET SP 1.1) ALSO | | | SHOWS THAT EXTERIOR MODIFICATIONS PROPOSED FOR THE | | | EXISTING RESIDENTIAL COMPLEX. SEPARATE PERMIT | | | APPLICATIONS AND REVIEWS WILL BE REQUIRED FOR THE | | | PROPOSED WORK (I.E. FREESTANDING SIGNAGE, NEW SHUFFLE | | | BOARD COURT, NEW PLAYGROUND, PERIMETER FENCING, | | | ENTRANCE GATES, ETC.). | | | | | | 3.) THERE SEEMS TO BE A PROPOSED "CAR CARE AREA." THE | | | CAR CARE AREA CANNOT BE PROVIDED UNLESS ADEQUATE | | | PARKING IS PROVIDED FOR THE RESIDENTIAL DEVELOPMENT. | | | PLEASE PROVIDE ADDITIONAL INFORMATION ON THE NUMBER OF | | | EXISTING PARKING SPACES AND IF THE EXISTING PARKING | | | MEETS CURRENT ZONING AND LAND DEVELOPMENT REGULATIONS | | | REQUIREMENT FOR THE USE. THIS INFORMATION SHOULD BE | | | DETAILED IN TABLE FORM IN THE SITE PLAN. | | | | | | 4.) PROVIDE DETAILS FOR THE PROPOSED FENCE AND GATE | | | SYSTEM. | | | | | | REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 | | | IF THERE ARE QUESTIONS. |
|
|